scholarly journals Intra-community spatial variability of particulate matter size distributions in Southern California/Los Angeles

2009 ◽  
Vol 9 (3) ◽  
pp. 1061-1075 ◽  
Author(s):  
M. Krudysz ◽  
K. Moore ◽  
M. Geller ◽  
C. Sioutas ◽  
J. Froines

Abstract. Ultrafine particle (UFP) number concentrations vary significantly on small spatial and temporal scales due to their short atmospheric lifetimes and multiplicity of sources. To determine UFP exposure gradients within a community, simultaneous particle number concentration measurements at a network of sites are necessary. Concurrent particle number size distribution measurements aid in identifying UFP sources, while providing data to investigate local scale effects of both photochemical and physical processes on UFP. From April to December 2007, we monitored particle number size distributions at 13 sites within 350 m–11 km of each other in the vicinity of the Ports of Los Angeles and Long Beach using Scanning Mobility Particle Sizers (SMPS). Typically, three SMPS units were simultaneously deployed and rotated among sites at 1–2 week intervals. Total particle number concentration measurements were conducted continuously at all sites. Seasonal and diurnal number size distribution patterns are complex, highly dependent on local meteorology, nearby PM sources, and times of day, and cannot be generalized over the study area nor inferred from one or two sampling locations. Spatial variation in particle number size distributions was assessed by calculating the coefficient of divergence (COD) and correlation coefficients (r) between site pairs. Results show an overall inverse relationship between particle size and CODs, implying that number concentrations of smaller particles (<40 nm) differ from site to site, whereas larger particles tend to have similar concentrations at various sampling locations. In addition, variations in r values as a function of particle size are not necessarily consistent with corresponding COD values, indicating that using results from correlation analysis alone may not accurately assess spatial variability.

2008 ◽  
Vol 8 (3) ◽  
pp. 9641-9672 ◽  
Author(s):  
M. Krudysz ◽  
K. Moore ◽  
M. Geller ◽  
C. Sioutas ◽  
J. Froines

Abstract. Ultrafine particle (UFP) number concentrations vary significantly on small spatial and temporal scales due to their short atmospheric lifetimes and multiplicity of sources. To determine UFP exposure gradients within a community, simultaneous particle number concentration measurements at a network of sites are necessary. Concurrent particle size distribution measurements aid in identifying UFP sources, while providing data to investigate local scale effects of both photochemical and physical processes on UFP. From April to December 2007, we monitored particle size distributions at 13 sites within 350 m to 11 km of each other in the vicinity of the Ports of Los Angeles and Long Beach using Scanning Mobility Particle Sizers (SMPS). Typically, three SMPS units were simultaneously deployed and rotated among sites at 1–2 week intervals. Total particle number concentration measurements were conducted continuously at all sites. Seasonal and diurnal size distribution patterns are complex, highly dependent on local meteorology, nearby PM sources, and times of day, and cannot be generalized over the study area nor inferred from one or two sampling locations. Spatial variation in particle number size distributions was assessed by calculating the coefficient of divergence (COD) and correlation coefficients (r) between site pairs. Results show an overall inverse relationship between particle size and CODs, implying that number concentrations of smaller particles (<40 nm) differ from site to site, whereas larger particles tend to have similar concentrations at various sampling locations. In addition, variations in r values as a function of particle size are not necessarily consistent with corresponding COD values, indicating that using results from correlation analysis alone may not accurately assess spatial variability.


2016 ◽  
Vol 9 (1) ◽  
pp. 103-114 ◽  
Author(s):  
G. I. Gkatzelis ◽  
D. K. Papanastasiou ◽  
K. Florou ◽  
C. Kaltsonoudis ◽  
E. Louvaris ◽  
...  

Abstract. An experimental methodology was developed to measure the nonvolatile particle number concentration using a thermodenuder (TD). The TD was coupled with a high-resolution time-of-flight aerosol mass spectrometer, measuring the chemical composition and mass size distribution of the submicrometer aerosol and a scanning mobility particle sizer (SMPS) that provided the number size distribution of the aerosol in the range from 10 to 500 nm. The method was evaluated with a set of smog chamber experiments and achieved almost complete evaporation (> 98 %) of secondary organic as well as freshly nucleated particles, using a TD temperature of 400 °C and a centerline residence time of 15 s. This experimental approach was applied in a winter field campaign in Athens and provided a direct measurement of number concentration and size distribution for particles emitted from major pollution sources. During periods in which the contribution of biomass burning sources was dominant, more than 80 % of particle number concentration remained after passing through the thermodenuder, suggesting that nearly all biomass burning particles had a nonvolatile core. These remaining particles consisted mostly of black carbon (60 % mass contribution) and organic aerosol (OA; 40 %). Organics that had not evaporated through the TD were mostly biomass burning OA (BBOA) and oxygenated OA (OOA) as determined from AMS source apportionment analysis. For periods during which traffic contribution was dominant 50–60 % of the particles had a nonvolatile core while the rest evaporated at 400 °C. The remaining particle mass consisted mostly of black carbon with an 80 % contribution, while OA was responsible for another 15–20 %. Organics were mostly hydrocarbon-like OA (HOA) and OOA. These results suggest that even at 400 °C some fraction of the OA does not evaporate from particles emitted from common combustion processes, such as biomass burning and car engines, indicating that a fraction of this type of OA is of extremely low volatility.


2013 ◽  
Vol 2013 ◽  
pp. 1-7 ◽  
Author(s):  
Fangyang Yuan ◽  
Fujun Gan

The method of moments is employed to predict the evolution of aerosol particles in the rainfall process. To describe the dynamic properties of particle size distribution, the population balance equation is converted to moment equations by the method of moments and the converted equations are solved numerically. The variations of particle number concentration, geometric mean diameter, and geometric standard deviation are given in the cases that the Brownian diffusion and inertial impaction of particles dominate, respectively. The effects of raindrop size distribution on particle size distribution are analyzed in nine cases. The results show that the particle number concentration decreases as time goes by, and particles dominated by Brownian diffusion are removed more significantly. The particle number concentration decreases much more rapidly when particle geometric mean diameter is smaller, and the particle size distribution tends to be monodisperse. For the same water content, the raindrops with small geometric mean diameters can remove particles with much higher efficiency than those with large geometric mean diameters. Particles in the “Greenfield gap” are relatively difficult to scavenge, and a new method is needed to remove it from the air.


2015 ◽  
Vol 8 (6) ◽  
pp. 6355-6393 ◽  
Author(s):  
G. I. Gkatzelis ◽  
D. K. Papanastasiou ◽  
K. Florou ◽  
C. Kaltsonoudis ◽  
E. Louvaris ◽  
...  

Abstract. An experimental methodology was developed to measure the non-volatile particle number concentration using a thermodenuder (TD). The TD was coupled with a high-resolution time-of-flight aerosol mass spectrometer, measuring the chemical composition and mass size distribution of the submicrometer aerosol and a scanning mobility particle sizer (SMPS) that provided the number size distribution of the aerosol in the range from 10 to 500 nm. The method was evaluated with a set of smog chamber experiments and achieved almost complete evaporation (> 98 %) of secondary organic as well as freshly nucleated particles, using a TD temperature of 400 °C and a centerline residence time of 15 s. This experimental approach was applied in a winter field campaign in Athens and provided a direct measurement of number concentration and size distribution for particles emitted from major pollution sources. During periods in which the contribution of biomass burning sources was dominant, more than 80 % of particle number concentration remained after passing through the thermodenuder, suggesting that nearly all biomass burning particles had a non-volatile core. These remaining particles consisted mostly of black carbon (60 % mass contribution) and organic aerosol, OA (40 %). Organics that had not evaporated through the TD were mostly biomass burning OA (BBOA) and oxygenated OA (OOA) as determined from AMS source apportionment analysis. For periods during which traffic contribution was dominant 50–60 % of the particles had a non-volatile core while the rest evaporated at 400 °C. The remaining particle mass consisted mostly of black carbon (BC) with an 80 % contribution, while OA was responsible for another 15–20 %. Organics were mostly hydrocarbon-like OA (HOA) and OOA. These results suggest that even at 400 °C some fraction of the OA does not evaporate from particles emitted from common combustion processes, such as biomass burning and car engines, indicating that a fraction of this type of OA is of extremely low volatility.


2006 ◽  
Vol 6 (3) ◽  
pp. 4081-4107 ◽  
Author(s):  
J. Voigtländer ◽  
T. Tuch ◽  
W. Birmili ◽  
A. Wiedensohler

Abstract. Combustion of fossil fuel in gasoline and diesel powered vehicles is a major source of aerosol particles in a city. In a street canyon, the number concentration of particles smaller than 300 nm in diameter, which can be inhaled and cause serious health effects, is dominated by particles originating from this source. In this study we measured both, particle number size distribution and traffic density continuously in a characteristic street canyon in Germany for a time period of 6 months. The street canyon with multistory buildings and 4 traffic lanes is very typical for larger cities. Thus, the measurements are also representative for many other street canyons. In contrast to previous studies, we measured and analyzed the particle number size distribution with high size resolution using a Twin Differential Mobility Analyzer (TDMPS). The measured size range was from 3 to 800 nm, separated into 40 size channels. Correlation coefficients between particle number concentration for integrated size ranges and traffic up to 0.5 counts were determined. Correlations were also calculated for each of the 40 size channels of the DMPS system, respectively. We found two maxima of the correlation coefficient for particles about 10 nm and in the size range 60–80 nm in diameter. Furthermore, correlations between traffic and particles in dependence of meteorological data were calculated. Relevant parameters were identified by a multiple regression method. In our experiment only wind parameters have influenced the particle number concentration significantly. Very high correlation coefficients (up to 0.85) could be observed in the lee side of the street canyon as well as particles in the range between 60 and 80 nm in diameter. These values are significantly higher than correlation coefficients for other wind directions and other particle sizes. A minimum was found in the luff side of the street. These findings are in good agreement with theory of fluid dynamics in street canyons.


2018 ◽  
Vol 18 (4) ◽  
pp. 2853-2881 ◽  
Author(s):  
Julia Schmale ◽  
Silvia Henning ◽  
Stefano Decesari ◽  
Bas Henzing ◽  
Helmi Keskinen ◽  
...  

Abstract. Aerosol–cloud interactions (ACI) constitute the single largest uncertainty in anthropogenic radiative forcing. To reduce the uncertainties and gain more confidence in the simulation of ACI, models need to be evaluated against observations, in particular against measurements of cloud condensation nuclei (CCN). Here we present a data set – ready to be used for model validation – of long-term observations of CCN number concentrations, particle number size distributions and chemical composition from 12 sites on 3 continents. Studied environments include coastal background, rural background, alpine sites, remote forests and an urban surrounding. Expectedly, CCN characteristics are highly variable across site categories. However, they also vary within them, most strongly in the coastal background group, where CCN number concentrations can vary by up to a factor of 30 within one season. In terms of particle activation behaviour, most continental stations exhibit very similar activation ratios (relative to particles > 20 nm) across the range of 0.1 to 1.0 % supersaturation. At the coastal sites the transition from particles being CCN inactive to becoming CCN active occurs over a wider range of the supersaturation spectrum. Several stations show strong seasonal cycles of CCN number concentrations and particle number size distributions, e.g. at Barrow (Arctic haze in spring), at the alpine stations (stronger influence of polluted boundary layer air masses in summer), the rain forest (wet and dry season) or Finokalia (wildfire influence in autumn). The rural background and urban sites exhibit relatively little variability throughout the year, while short-term variability can be high especially at the urban site. The average hygroscopicity parameter, κ, calculated from the chemical composition of submicron particles was highest at the coastal site of Mace Head (0.6) and lowest at the rain forest station ATTO (0.2–0.3). We performed closure studies based on κ–Köhler theory to predict CCN number concentrations. The ratio of predicted to measured CCN concentrations is between 0.87 and 1.4 for five different types of κ. The temporal variability is also well captured, with Pearson correlation coefficients exceeding 0.87. Information on CCN number concentrations at many locations is important to better characterise ACI and their radiative forcing. But long-term comprehensive aerosol particle characterisations are labour intensive and costly. Hence, we recommend operating “migrating-CCNCs” to conduct collocated CCN number concentration and particle number size distribution measurements at individual locations throughout one year at least to derive a seasonally resolved hygroscopicity parameter. This way, CCN number concentrations can only be calculated based on continued particle number size distribution information and greater spatial coverage of long-term measurements can be achieved.


2017 ◽  
Author(s):  
Julia Schmale ◽  
Silvia Henning ◽  
Stefano Decesari ◽  
Bas Henzing ◽  
Helmi Keskinen ◽  
...  

Abstract. Aerosol-cloud interactions (ACI) constitute the single largest uncertainty in anthropogenic radiative forcing. To reduce the uncertainties and gain more confidence in the simulation of ACI, models need to be evaluated against observations, in particular against measurements of cloud condensation nuclei (CCN). Numerous observations of CCN number concentration exist, and many closure studies have been performed to predict CCN number concentrations based on particle number size distributions, chemical composition, and the κ-Köhler theory. Most of these studies provide details for short time periods or focus on special environmental conditions. These observations, however, cannot address questions of large-scale temporal and spatial CCN variability. Here we analyze long-term observations of CCN number concentrations, particle number size distributions and chemical composition from twelve sites on three continents. Eight of these stations are part of the European Aerosols, Clouds, and Trace gases Research InfraStructure (ACTRIS). We group the observatories into categories according to their official classification: coastal background (Barrow, Alaska; Mace Head, Ireland; Finokalia, Crete; Noto Peninsula, Japan), rural background (Melpitz, Germany; Cabauw, the Netherlands; Vavihill, Sweden), alpine sites (Puy de Dôme, France; Jungfraujoch, Switzerland), remote forest sites (ATTO, Brazil; SMEAR, Finland) and the urban environment (Seoul, South Korea). Expectedly, CCN characteristics are highly variable across regions. However, they also vary within categories, most strongly in the coastal background group, where CCN number concentrations can vary by up to a factor of 30 within one season. In terms of particle activation behavior, most continental stations exhibit very similar relative activation ratios across the range of 0.1 to 1.0 % supersaturation. At the coastal sites the activation ratios spread more widely across the SS spectrum. Several stations show strong seasonal cycles of CCN number concentrations and particle number size distributions, e.g., at Barrow (Arctic Haze in spring), at the alpine stations (stronger influence of polluted boundary layer air masses in summer), the rain forest (wet and dry season), or Finokalia (forest fire influence in fall). The rural background and urban sites exhibit relatively little variability throughout the year while short-term variability can be high especially at the urban site. The average hygroscopicity parameter, κ, calculated from the chemical composition of submicron particles, was highest at the coastal site of Mace Head (0.6) and the lowest at the rain forest station ATTO (0.2–0.3). We performed closure studies to predict CCN number concentrations from the particle number size distribution and chemical composition measurements. The prediction accuracy for the average concentrations is high. The ratio between predicted and measured CCN concentrations is between 0.87 and 1.4. The temporal variability is also well represented, as reflected by Pearson correlation coefficients > 0.87. We also conducted a series of sensitivity studies for the ratio of predicted versus measured CCN concentration, where we varied the hygroscopicity parameter κ, and made simple assumptions for aerosol particle number concentrations and size distributions. Uncertain particle number concentrations and their size distributions significantly impair the accuracy in predicting temporal variability and hence of absolute concentrations, while the effect of uncertain κ values is limited to the predicted CCN number concentration. Information on CCN number concentrations at many locations is important to better characterize ACI and their radiative forcing. Long-term comprehensive aerosol particle characterizations are labor intensive and costly. For observatories where such efforts are out of scope to obtain nevertheless long-term information of CCN number concentrations, we recommend conducting collocated CCN number concentration and particle number size distribution measurements at individual locations throughout one year at least to derive a seasonally resolved hygroscopicity parameter. This way, CCN number concentrations can be calculated based on continued particle number size distribution information only. This approach is a good alternative to deriving kappa from time-resolved chemical composition measurements which are costly and may still not cover the appropriate size range. Additionally, given the variability in observations at sites of the same category, a certain density in spatial coverage of observations is needed, especially along coastlines. We recommend operating "migrating-CCNCs" at priority locations, identified by model evaluation, around the globe where long-term particle number size distribution data are already available.


2006 ◽  
Vol 6 (12) ◽  
pp. 4275-4286 ◽  
Author(s):  
J. Voigtländer ◽  
T. Tuch ◽  
W. Birmili ◽  
A. Wiedensohler

Abstract. Combustion of fossil fuel in gasoline and diesel powered vehicles is a major source of aerosol particles in a city. In a street canyon, the number concentration of particles smaller than 300 nm in diameter, which can be inhaled and cause serious health effects, is dominated by particles originating from this source. In this study we measured both, particle number size distribution and traffic density continuously in a characteristic street canyon in Germany for a time period of 6 months. The street canyon with multistory buildings and 4 traffic lanes is very typical for larger cities. Thus, the measurements also are representative for many other street canyons in Europe. In contrast to previous studies, we measured and analyzed the particle number size distribution with high size resolution using a Twin Differential Mobility Analyzer (TDMPS). The measured size range was from 3 to 800 nm, separated into 40 size channels. Correlation coefficients between particle number concentration for integrated size ranges and traffic counts of 0.5 were determined. Correlations were also calculated for each of the 40 size channels of the DMPS system, respectively. We found a maximum of the correlation coefficients for nucleation mode particles in the size range between 10 and 20 nm in diameter. Furthermore, correlations between traffic and particles in dependence of meteorological data were calculated. Relevant parameters were identified by a multiple regression method. In our experiment only wind parameters have influenced the particle number concentration significantly. High correlation coefficients (up to 0.8) could be observed in the lee side of the street canyon for particles in the range between 10 and 100 nm in diameter. These values are significantly higher than correlation coefficients for other wind directions and other particle sizes. A minimum was found in the luff side of the street. These findings are in good agreement with theory of fluid dynamics in street canyons.


2020 ◽  
Author(s):  
Jiangchuan Tao ◽  
Nan Ma ◽  
Yanyan Zhang ◽  
Ye Kuang ◽  
Juan Hong ◽  
...  

&lt;p&gt;CCN number concentration (N&lt;sub&gt;CCN&lt;/sub&gt;), particle size-resolved activation ratio at supersaturation (SS) of 0.10% and particle number size distribution (PNSD) in dry state of both ambient PM1 and PM10 particles were measured in the North China Plain in November in 2018. Two fog events were observed during nighttime of 12nd and 13rd Nov. During fog events, the dry particle concentrations sampled from the PM10 inlet were much higher than those from PM1 inlet for particles (particle size bins) with diameter larger than ~200 nm. Additional sub-micron particles sampled by PM10 inlet but not been sampled by PM1 inlet indicates that these particles have grown into droplets with diameter larger than 1um. The growth of particle size by over 5 times can be resulted from not only the activation to form fog droplets but also the hygroscopic growth at RH higher than 99%. There was no significant decrease of particle number concentration larger than ~200 nm during fog periods compared with those beyond the fog periods, suggesting that the fog droplets may be generally smaller than 10um and can be sampled by PM10 inlet. The size-resolved activation ratio curve showed that the critical diameter was about 160-180nm and there was significant difference (&gt;50%) of N&lt;sub&gt;CCN&lt;/sub&gt; at SS of 0.1% between PM1 and PM10, mainly due to the difference of PNSD between PM1 and PM10 in fogs. The measured PNSD and CCN-activity might be applied on the analysis of the relationship between fog droplets and the corresponding ambient supersaturations.&lt;/p&gt;


Author(s):  
Jiali Shen ◽  
Alessandro Bigi ◽  
Angela Marinoni ◽  
Janne Lampilahti ◽  
Jenni Kontkanen ◽  
...  

Impact of lockdown measures on the air pollutants and particle number size distribution.


Sign in / Sign up

Export Citation Format

Share Document