Use of String of Pearls Locking Plate System For Stabilization of Femoral Fractures in Canines

Author(s):  
GURRALA REDDY ◽  
V KUMAR ◽  
K RAGHAVENDER ◽  
PRAMOD D
VCOT Open ◽  
2019 ◽  
Vol 02 (02) ◽  
pp. e50-e55
Author(s):  
Darby W. Walmsley ◽  
Tania Shaw ◽  
Simon T. Kudnig

Abstract Objectives The aim of this study was to describe a case of an intra-articular olecranon fracture in a lamb repaired using a String of Pearls locking plate system, intramedullary pin and lag screws. Materials and Methods A 6-month-old, 20 kg, purebred male Merino lamb was referred for evaluation of a non-weight bearing lameness of the left thoracic limb of unknown duration. Orthogonal radiographic assessment of the left elbow revealed a complete, closed, long sagittal oblique, minimally displaced fracture of the olecranon involving the ulnar shaft at the level of the radial physis, extending proximally through the distal semilunar notch to the mid-body of the olecranon. The fracture was repaired using a String of Pearls locking plate system spanning both the proximal radius and olecranon, an intramedullary pin in the ulna and lag screws across the fracture line. Results Orthogonal radiographic assessment of the left elbow at 8 weeks postoperatively revealed implant quiescence with radiographic union of the fracture site. Long-term telephone follow-up at 3 and 6 months postoperatively found the patient was no longer restricted in activity, with free access to the field, and was not displaying an overt lameness. Clinical Significance The authors describe a novel method to treat an intra-articular in a lamb olecranon fracture in a lamb using a String of Pearls locking plate system, intramedullary pin and lag screws.


2011 ◽  
Vol 2011 ◽  
pp. 1-4
Author(s):  
A. B. Scrimgeour ◽  
A. J. Worth

An eight-year-old male Pyrenean mountain dog was presented with a comminuted fracture of the right calcaneus following motor vehicle trauma. The fracture was stabilised with a plate-rod construct, using the String of Pearls locking plate system and an intramedullary pin. Healing was uncomplicated.


2015 ◽  
Vol 28 (04) ◽  
pp. 288-293 ◽  
Author(s):  
T. Nicetto ◽  
M. Petazzoni

SummaryObjectives: To describe the use of the Fixin locking plate system for stifle arthrodesis in dogs and to retrospectively report the clinical and radiographic outcomes in six cases.[uni2028]Materials and methods: Medical records of dogs that had arthrodesis with the Fixin locking plate system were reviewed. For each patient, data pertaining to signalment and implant used were recorded. Plate series and thickness, number of screws placed, number of cortices engaged, and screw diameters were also recorded. The outcome was determined from clinical and radiographic followups. Radiographic outcomes assessed included the measurement of the postoperative femoral-tibial angle in the sagittal plane.Results: Six dogs met the inclusion criteria for the study. Mean body weight was 13 kg (range: 3 - 34 kg). Radiographic follow-up (mean: 32 weeks, range: 3 - 52 weeks) was available for all dogs. In one case, an intra-operative complication occurred. In another case, a tibial fracture occurred 20 days after surgery. All arthrodeses healed and no implant complication was detected although all cases had mechanical lameness.Clinical significance: Stifle arthrodesis can be performed successfully using a Fixin locking plate system.


Sign in / Sign up

Export Citation Format

Share Document