Validated Spectrophotometric and RP-HPLC–DAD Methods for the Determination of Ursodeoxycholic Acid Based on Derivatization with 2-Nitrophenylhydrazine

2017 ◽  
Vol 100 (3) ◽  
pp. 677-685
Author(s):  
Dina S El-Kafrawy ◽  
Tarek S Belal ◽  
Mohamed S Mahrous ◽  
Magdi M Abdel-Khalek ◽  
Amira H Abo-Gharam

Abstract This work describes the development, validation, and application of two simple, accurate, and reliable methods for the determination of ursodeoxycholic acid (UDCA) in bulk powder and in pharmaceutical dosage forms. The carboxylic acid group in UDCA was exploited for the development of these novel methods. Method 1 is the colorimetric determination of the drug based on its reaction with 2-nitrophenylhydrazine hydrochloride in the presence of a water-soluble carbodiimide coupler [1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide hydrochloride] and pyridine to produce an acid hydrazide derivative, which ionizes to yield an intense violet color with maximum absorption at 553 nm. Method 2 uses reversed-phase HPLC with diode-array detection for the determination of UDCA after precolumn derivatization using the same reaction mentioned above. The acid hydrazide reaction product was separated using a Pinnacle DB C8 column (4.6 × 150 mm, 5 μm particle size) and a mobile phase consisting of 0.01 M acetate buffer (pH 3)–methanol–acetonitrile (30 + 30 + 40, v/v/v) isocratically pumped at a flow rate of 1 mL/min. Ibuprofen was used as the internal standard (IS). The peaks of the reaction product and IS were monitored at 400 nm. Different experimental parameters for both methods were carefully optimized. Analytical performance of the developed methods were statistically validated for linearity,range, precision, accuracy, specificity, robustness, LOD, and LOQ. Calibration curves showed good linear relationships for concentration ranges 32–192 and 60–600 μg/mL for methods 1 and 2, respectively. The proposed methods were successfully applied for the assay of UDCA in bulk form, capsules, and oral suspension with good accuracy and precision. Assay results were statistically compared with a reference pharmacopeial HPLC method, and no significant differences were observed between proposed and reference methods.

2007 ◽  
Vol 4 (1) ◽  
pp. 109-116 ◽  
Author(s):  
K. Basavaiah ◽  
B. C. Somashekar

A rapid, highly sensitive high performance liquid chromatographic method has been developed for the determination of finasteride(FNS) in bulk drug and in tablets. FNS was eluted from a ODS C18reversed phase column at laboratory temperature (30 ± 2°C) with a mobile phase consisting of methanol and water (80+20) at a flow rate of 1 mL min-1with UV detection at 225 nm. The retention time was ∼ 6.1 min and each analysis took not more than 10 min. Quantitation was achieved by measurement of peak area without using any internal standard. Calibration graph was linear from 2.0 to 30 μg mL-1with limits of detection (LOD) and quantification (LOQ) being 0.2 and 0.6 μg mL-1, respectively. The method was validated according to the current ICH guidelines. Within-day co efficients of variation (CV) ranged from 0.31 to 0.69% and between-day CV were in the range 1.2-3.2%. Recovery of FNS from the pharmaceutical dosage forms ranged from 97.89 – 102.9 with CV of 1.41-4.13%. The developed method was compared with the official method for FNS determination in its tablet forms.


1983 ◽  
Vol 29 (4) ◽  
pp. 672-674 ◽  
Author(s):  
P M Kabra ◽  
P K Bhatnagar ◽  
M A Nelson ◽  
J H Wall ◽  
L J Marton

Abstract We describe a simple, precise, accurate, and specific liquid-chromatographic procedure for determination of tobramycin in 50 microL of serum. Tobramycin and the internal standard (sisomicin) are quantitatively converted into their trinitrophenyl derivatives by reaction with a water-soluble derivatizing agent (2,4,6-trinitrobenzenesulfonic acid) at 70 degrees C for 30 min. The derivatives are extracted from the crude reaction mixture by using a reversed-phase Bond-Elut C18 column, and separated on a reversed-phase octyl column with a mobile phase consisting of an acetonitrile/phosphate buffer (70/30 by vol) at a flow rate of 3.0 mL/min. The eluted compounds are detected at 340 nm, and quantified from their peak areas. Chromatography is complete in less than 4.5 min at the optimum column temperature of 50 degrees C. The lower limit of detection for tobramycin is less than 0.2 mg/L. Analytical recoveries for tobramycin varied from 94 to 99%, linearity extended to 25 mg/L, and day-to-day precision (CV) was between 4.6 and 5.1%. Numerous drugs and antibiotics tested do not interfere. Results correlate well (r greater than 0.95) with those by radioimmunoassay and EMIT.


2020 ◽  
Vol 17 (1) ◽  
pp. 95-105
Author(s):  
Ramji Rathod ◽  
Faraat Ali ◽  
Amrish Chandra ◽  
Robin Kumar ◽  
Meenakshi Dahiya ◽  
...  

Background: A simple and sensitive Ultra Performance Liquid Chromatography-Mass Spectrometry method was developed and validated to measure the concentrations of Alogliptin (ALO), Linagliptin (LIN), Saxagliptin (SAX), and Sitagliptin (SIT) using Pioglitazone (PIO) as an internal standard. Methods: Chromatographic separation of six gliptins was achieved on a C-18 column (100×2.1 mm, 2.7 μm) using a mobile phase consisting of formic acid in water, 0.1%v/v: acetonitrile in gradient elution. Electrospray ionization (ESI) source was operated in the positive ion mode. Targeted MS/MS mode on a QTOF MS was used to quantify the drug utilizing the transitions of 340.1(m/z), 473.2 (m/z), 316.2 (m/z), 408.1 (m/z), and 357.1 (m/z) for ALO, LIN, SAX, SIT and PIO respectively. Results: As per ICH Q2R1 guidelines, a detailed validation of the method was carried out and the standard curves were found to be linear over the concentration ranges of 1516.0-4548.1 ng mL-1, 519.8- 1559.4 ng mL-1, 1531.4-4594.3 ng mL-1and 1519.6-4558.8 ng mL-1 for ALO, LIN, SAX and SIT respectively. Precision and accuracy results were within the acceptable limits. The mean recovery was found to be 98.8 _ 0.76 % (GEM), 102.2 _ 1.59 % (LIN), 95.3 _ 2.74 % (SAX) and 99.2 _ 1.75 % (SIT) respectively. Conclusions: The optimized validated UPLC QTOF-MS/MS method offered the advantage of shorter analytical times and higher sensitivity and selectivity. The optimized method is suitable for application in quantitative analysis of pharmaceutical dosage forms for QC laboratory.


2020 ◽  
Vol 10 (2) ◽  
pp. 122-129
Author(s):  
Haoyu Lv ◽  
Yabin Tang ◽  
Fan Sun ◽  
Shimin An ◽  
Xinjie Yang ◽  
...  

Background:In recent years, more and more researches have shown that neurotransmitters can also be synthesized and released by peripheral non-neural cells. However, specificity and high sensitivity detection means were required for confirming ESCs autocrine glutamate and γ - aminobutyric acid (GABA). Glutamate and GABA are water-soluble and polar compounds which cannot be retained on a reversed phase C18 column, and their contents are often at a trace level. On the other hand, the biological matrix such as cell culture fluid contains a large number of amino acids, vitamins, carbohydrates, inorganic ions and other substances. Therefore, the main problem is the selection of the chromatographic column to avoid matrix interference.Objective:To establish a rapid and reliable method for the simultaneous determination of glutamate and GABA released from embryonic stem cells based on analytical chemistry.Methods:Glutamate and GABA released from mouse embryonic stem cells were determined on the basis of hydrophilic interaction chromatography coupled with electrospray ionization tandem Mass Spectrometry (HILIC- ESI- MS/MS), using isotope internal standards and substitution matrix method.Results:Undifferentiated embryonic stem cells autocrine glutamate and GABA and will reach releasing- reuptacking dynamic equilibriums at different time points. In contrast, neither glutamate nor GABA releasing could be detected from the MEFs, indicating the specificity release of the mESCs in the applied analytic method.Conclusion:A novel, simple, sensitive, selective and quantitative method was developed for determination of the glutamate and GABA from mouse embryonic stem cells.


2002 ◽  
Vol 35 (2) ◽  
pp. 183-197 ◽  
Author(s):  
Mohamed H. Abdel-Hay ◽  
Amal Saleh ◽  
E. S. H. El Ashry ◽  
N. Rashed ◽  
Osama Salama

2013 ◽  
Vol 96 (6) ◽  
pp. 1302-1307 ◽  
Author(s):  
Karim Michail ◽  
Hoda Daabees ◽  
Youssef Beltagy ◽  
Magdy Abd Elkhalek ◽  
Mona Khamis

Abstract A validated HPLC-UV method is presented for the quantification of urinary memantine hydrochloride, a novel medication approved to treat moderate and advanced cases of Alzheimer's disease. The drug and amantadine hydrochloride, the internal standard, were extracted from human urine using SPE. The extract was then buffered and derivatized at room temperature using o-phthalaldehyde in the presence of N-acetyl-L-cyteine. Chromatographic separation of the formed derivatives was achieved on a C18 column using methanol–water mobile phase adjusted to pH 7 and pumped isocratically at 1 mL/min. The UV detector was set at 340 nm. The chromatographic run time did not exceed 10 min. The LOD and LOQ were 8 and 20 ng/mL, respectively. The RSDs for intraday and interday precisions did not exceed 5.5%. The method was used to monitor memantine hydrochloride in human urine in order to determine an appropriate sampling interval for future noninvasive therapeutic drug monitoring. The assay could also be applied to the determination of amantadine. The described assay showed that a postdosing time interval of 25–75 h seems adequate for sampling and monitoring memantine in urine.


2017 ◽  
Vol 20 (2) ◽  
pp. 241-249 ◽  
Author(s):  
A. Jasiecka-Mikołajczyk ◽  
J.J. Jaroszewski

Abstract Tigecycline (TIG), a novel glycylcycline antibiotic, plays an important role in the management of complicated skin and intra-abdominal infections. The available data lack any description of a method for determination of TIG in avian plasma. In our study, a selective, accurate and reversed-phase high performance liquid chromatography-tandem mass spectrometry method was developed for the determination of TIG in turkey plasma. Sample preparation was based on protein precipitation and liquid-liquid extraction using 1,2-dichloroethane. Chromatographic separation of TIG and minocycline (internal standard, IS) was achieved on an Atlantis T3 column (150 mm × 3.0 mm, 3.0 μm) using gradient elution. The selected reaction monitoring transitions were performed at 293.60 m/z → 257.10 m/z for TIG and 458.00 m/z → 441.20 m/z for IS. The developed method was validated in terms of specificity, selectivity, linearity, lowest limit of quantification, limit of detection, precision, accuracy, matrix effect, carry-over effect, extraction recovery and stability. All parameters of the method submitted to validation met the acceptance criteria. The assay was linear over the concentration range of 0.01-100 μg/ml. This validated method was successfully applied to a TIG pharmacokinetic study in turkey after intravenous and oral administration at a dose of 10 mg/kg at various time-points.


2016 ◽  
Vol 13 (2) ◽  
pp. 447-457 ◽  
Author(s):  
Baghdad Science Journal

High-performance liquid chromatographic methods are used for the determination of water-soluble vitamins with UV-Vis. Detector. A reversed-phase high-performance liquid chromatographic has been developed for determination of water-soluble vitamins. Identification of compounds was achieved by comparing their retention times and UV spectra with those of standards solution. Separation was performed on a C18 column, using an isocratic 30% (v/v) acetonitril in dionozed water as mobile phase at pH 3.5 and flow rate 1.0m/min. The method provides low detection and quantification limits, good linearity in a large concentration interval and good precision. The detection limits ranged from 0.01 to 0.025µg/ml. The accuracy of the method was tested by measuring average recovery values ranged between 94% - 101 %. For standerd solution, and 93%-99% of honey bee samples.


Sign in / Sign up

Export Citation Format

Share Document