scholarly journals Dedicated Monte Carlo Procedures Applied in Gamma-ray Spectrometry Used in Decommissioning of Nuclear Facilities

10.5772/62937 ◽  
2016 ◽  
Author(s):  
Daniela Gurau
2021 ◽  
Author(s):  
David Breitenmoser

<p>The objective of this work is to simulate the spectral gamma-ray response of NaI(Tl) scintillation detectors for airborne gamma-ray spectrometry (AGRS) using Monte Carlo radiation transport codes. The study is based on a commercial airborne gamma-ray spectrometry detector system with four individual NaI(Tl) scintillation crystals and a total volume of 16.8 l. Monte Carlo source-detector simulations were performed in an event-by-event mode with the commercial multi-purpose transport codes MCNP6.2 and FLUKA. Validation measurements were conducted using <sup>241</sup>Am, <sup>133</sup>Ba, <sup>60</sup>Co, <sup>137</sup>Cs and <sup>152</sup>Eu radiation sources with known activities and source-detector geometries. Energy resolution functions were derived from these measurements combined with additional measurements of natural Uranium, Thorium and Potassium sources. The simulation results are in good agreement with the experimental data with a maximum relative error in the full-energy peak counts of 10%. In addition, no significant difference between the two Monte Carlo radiation transport codes was found with respect to a 95% confidence level. The validated detector model presented herein can be adopted for angular detector response analysis and calibration computations relating radionuclide activity concentrations with spectral detector counts.</p>


Nukleonika ◽  
2015 ◽  
Vol 60 (3) ◽  
pp. 545-550 ◽  
Author(s):  
Guillaume Lutter ◽  
Faidra Tzika ◽  
Mikael Hult ◽  
Michio Aoyama ◽  
Yasunori Hamajima ◽  
...  

Abstract Following the accident at the Daiichi Fukushima nuclear power plant in 2011, a vast number of Pacific seawater samples from many locations far from Fukushima have been collected by Japanese investigators. Due to dilution, the activities of radionuclides from North Pacific seawater samples are very low, which calls for extraordinary measures when being measured. This study focuses on the metrological aspects of the gamma-ray spectrometry measurements performed on such samples in two underground laboratories; at HADES (by JRC-IRMM in Belgium), and at Ogoya (by Kanazawa University in Japan). Due to many samples and long measurement times, all available HPGe detectors needed to be employed. In addition to single coaxial detectors, this involved multidetector systems and well detectors. Optimization of detection limits for different radionuclides and detectors was performed using Monte Carlo simulations.


Sign in / Sign up

Export Citation Format

Share Document