scholarly journals Tangential View and Intraoperative Three-Dimensional Fluoroscopy for the Detection of Screw-Misplacements in Volar Plating of Distal Radius Fractures

2015 ◽  
Vol 4 (2) ◽  
Author(s):  
Sascha Rausch ◽  
Ivan Marintschev ◽  
Isabel Graul ◽  
Arne Wilharm ◽  
Kajetan Klos ◽  
...  
Author(s):  
Jasper Prijs ◽  
Bram Schoolmeesters ◽  
Denise Eygendaal ◽  
Jean-Paul P. M. de Vries ◽  
Paul C. Jutte ◽  
...  

Abstract Purpose To evaluate the effect of three-dimensional virtual pre-operative planning (3DVP) on the incidence of dorsal screw penetration after volar plating of distal radius fractures. Methods A cross-sectional diagnostic imaging study was performed. Twenty out of 50 patients were randomly selected from our index prospective cohort (IPC): a prior study evaluating dorsal tangential views (DTVs) in reducing dorsal screw penetration in internal fixation of intra-articular distal radius fractures using post-operative CT scans to quantify screw protrusion. Pre-operative CTs from this cohort were now used for 3DVP by three experienced orthopaedic trauma surgeons (supplementary video). 3DVP was compared with the corresponding post-operative CT for assessing screw lengths and incidence of dorsal penetration. The Wilcoxon Signed Ranks test was used to compare screw lengths and the Fishers’ exact for incidence of penetration. Results Three surgeons performed 3DVP for 20 distal radius fractures and virtually applied 60 volar plates and 273 screws. Median screw length was shorter in the 3DVP when compared to IPC: 18 mm (range, 12–22) versus 20 mm (range, 14–26) (p < 0.001). The number of penetrating screws was 5% (13/273 screws) in the 3DVP group compared to 11% (10/91 screws) in the IPC (p = 0.047). Corresponding to a reduction in incidence of at least one dorsally penetrating screw in 40% of patients in the IPC group, to 18% in the 3DVP group (p = 0.069). Conclusion Three-Dimensional Virtual Pre-Operative Planning (3DVP) may reduce the incidence of dorsally penetrating screws in patients treated with volar plating for intra-articular distal radius fractures. Level of evidence II, diagnostic imaging study.


2020 ◽  
Author(s):  
Xue-yang Gui ◽  
Hong-fei Shi ◽  
Jin Xiong ◽  
Yi-xin Chen ◽  
Jun-fei Wang ◽  
...  

Abstract Backgrounds: The aim of this study was to assess the efficacy of a modified intrafocal pinning technique with three-dimensional (3D) planning to facilitate volar plating in dorsally comminuted intra-articular distal radius fractures.Methods: In total 35 AO/OTA type C2 and C3 fractures were finally included. The 3D digital model of the fracture was reconstructed based on preoperative computed tomographic (CT) images, with the displacement of the comminuted dorsal fragment and the intra-articular fragment analyzed for preoperative planning. During operation, a modified intrafocal pinning technique was applied percutaneously from the dorsal aspect of the radius to reduce the collapsed intra-articular fragment following volar plating. Adequate reduction was confirmed in all of patients considering radial height, radial inclination and volar tilt in postoperative radiographs.Results: No significant fracture re-displacement was observed in most of the cases during a mean follow-up period of 17.4 months, except for two patients with the C3 fracture. All of the patients achieved adequate clinical ROMs at 12 months postoperatively, with a mean DASH score of 12.0. Most of the patients achieved an excellent (n = 21) or good (n = 12) Gartland and Werley wrist score.Conclusions: Our modified intrafocal pinning technique with 3D planning contributes to a satisfactory clinical and radiological outcome in dorsally comminuted intra-articular distal radius fractures fixed with a volar locking plate.Trial registration: Not applicable because the design of the study is retrospective.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Xue-yang Gui ◽  
Hong-fei Shi ◽  
Jin Xiong ◽  
Yi-xin Chen ◽  
Jun-fei Wang ◽  
...  

Abstract Backgrounds Theaim of this study was to assess the efficacy of a modified intrafocal pinningtechnique with three-dimensional (3D) planning to facilitate volar plating in dorsally comminuted intra-articular distal radius fractures. Methods Intotal 35 AO/OTA type C2 and C3 fractures were finally included.The 3D digital model of the fracture was reconstructed based on preoperative computedtomographic (CT) images, with the displacement of the comminuted dorsalfragment and the intra-articular fragment analyzed for preoperative planning. During operation, amodified intrafocal pinning technique was applied percutaneously from thedorsal aspect of the radius to reduce the collapsed intra-articular fragmentfollowing volar plating. Adequate reduction was confirmed in all of patientsconsidering radial height, radial inclination and volar tilt in postoperativeradiographs. Results No significant fracture re-displacement wasobserved in most of the cases during a mean follow-up period of 17.4 months, exceptfor two patients withthe C3 fracture. All of the patients achieved adequate clinicalROMs at 12 months postoperatively, with a mean DASH score of 12.0. Most of the patients achievedan excellent (n = 21) or good (n = 12) Gartland and Werley wrist score. Conclusions Ourmodified intrafocal pinning technique with 3D planning contributes to a satisfactoryclinical and radiological outcome in dorsally comminuted intra-articular distalradius fractures fixed with a volar locking plate. Trialregistration Notapplicable because the design of the study is retrospective.


2021 ◽  
Vol 108 (Supplement_2) ◽  
Author(s):  
J Mulrain ◽  
K Joshi ◽  
F Doyle ◽  
A Abdulkarim

Abstract Introduction Distal radius fractures are common and trends for fixation have changed with increased use of volar locking plates in recent time. A meta-analysis will summarise the best evidence for treatment. Method A systematic review was conducted using PRISMA methodology to identify studies that reported clinical and/or radiological outcomes in patients with AO type C distal radius fractures when treated with external fixation versus ORIF. Results 10 randomised trials were included in this review, reporting on 967 patients. Clinical outcomes are in favour of volar plating at 3 months post-operation, but no difference between the two groups is seen at 6 or 12 months. Analysis of complication rates shows a minute increase in risk-ratio for volar plating versus external fixation. Subgroup analysis showed significantly higher re-operations after plate fixation and significantly higher infection after external fixation. Conclusions Internal fixation of complex distal radius fractures confers an improved clinical outcome at early follow up only and a minimally increased risk of complications. The improved grip strength with volar plating is only superior at early follow up and no long-term superiority is seen with either intervention. The type of surgery in this injury type therefore remains at the surgeon’s consideration on a case-by-case basis.


Author(s):  
M. Carolina Orbay ◽  
Jorge L. Orbay

AbstractGreater understanding of specific fracture patterns following distal radius fractures has arisen with the advent of volar plating. The volar marginal fragment (VMF) is a small peripheral piece of bone which is critical to carpal stability. Failure to achieve good fixation of the VMF can result in volar subluxation of the carpus and distal radioulnar joint instability. Due to its small, distal nature, this fragment can be easily missed and difficult to fix. Loss of reduction of the VMF following operative fixation presents specific challenges and surgical considerations dictated by patient characteristics and timing. Our goal of this review is to present a classification system for these failed VMFs which can help guide surgical treatment as well as expected outcomes.


2017 ◽  
Vol 43 (2) ◽  
pp. 142-147 ◽  
Author(s):  
Daniel Martinez-Mendez ◽  
Alejandro Lizaur-Utrilla ◽  
Joaquin de-Juan-Herrero

We compared outcomes in elderly patients with intra-articular distal radius fractures treated by closed reduction and plaster immobilization or open reduction and internal fixation with a volar plate. Ninety-seven patients older than 60 years were randomly allocated to conservative (47 patients) or surgical (50 patients) treatment. Over a 2-year period, we assessed patient-rated wrist evaluation score, DASH (disability arm, shoulder and hand) questionnaire, pain, wrist range of motion, grip strength, and radiological parameters. The functional outcomes and quality of life were significantly better after volar plating fixation compared with conservative treatment. We found that restoration of the articular surface, radial inclination, and ulnar variance affected the outcomes, but the articular step-off did not. Twenty-five per cent of the patients with conservative treatment had secondary loss of reduction. We conclude that surgical plating leads to better outcomes than conservative treatment for elderly patients with intra-articular distal radius fractures. Level of evidence: I


2021 ◽  
pp. 445-459
Author(s):  
Stephanie Catherine Spence ◽  
Benjamin Hope ◽  
Mark Ross

Sign in / Sign up

Export Citation Format

Share Document