Continuous Quality Improvement for Point-of-Care Testing Using Background Monitoring of Duplicate Specimens

1999 ◽  
Vol 123 (9) ◽  
pp. 824-828
Author(s):  
Meredith L. Kilgore ◽  
Steven J. Steindel ◽  
John A. Smith

Abstract Context.—Despite compliance with quality control standards, concerns remain as to the accuracy and reliability of point-of-care testing. Objective.—To assess a practical method for quality improvement using the context in which point-of-care testing is done. Design.—Quality measures for point-of-care testing, making use of natural duplication of results obtained by other testing methods, were used to monitor testing quality and evaluate quality improvement interventions. Setting.—Five adult intensive care units (total of 88 beds) in a large academic medical center, using point-of-care testing for blood gases, electrolytes, and hematocrit levels. Participants.—Nurses performing bedside testing and laboratory personnel assigned the responsibility for supervising their performance. Interventions.—Quality of testing was monitored continuously, and, where problems were identified, training and support interventions implemented, and their effects evaluated. Main Outcome Measures.—Improvement in correlation coefficients and regression parameters of point-of-care hematocrit and potassium testing results compared with contemporaneous results from the core laboratory. Results.—The initial survey found point-of-care potassium levels were tightly correlated with core laboratory results (r = 0.958). Baseline correlation coefficients and regression parameters for point-of-care hematocrit levels compared with core laboratory values varied widely from unit to unit. The intensive care units with the highest variances of bedside vs core laboratory testing received targeted interventions. Follow-up yielded evidence of dramatic improvement; 1 unit experienced an increase in correlation from 0.50 to 0.95. Conclusions.—The findings suggest that, when point-of-care testing is highly dependent on operator technique, targeted interventions can resolve problems and provide reliable results at the bedside.

2018 ◽  
Author(s):  
T Léguillier ◽  
R Jouffroy ◽  
M Boisson ◽  
A Boussaroque ◽  
C Chenevier-Gobeaux ◽  
...  

Author(s):  
Larisa B. Gaikovaya ◽  
Sergey A. Saiganov ◽  
Elguja L. Lataria ◽  
Olga V. Gramatovich ◽  
Anastasia S. Fedorenko ◽  
...  

The economic rationale for the choice of a portable analyzer of gases and electrolytes for their use in the resuscitation and intensive care units, as well as implementing the “point of care testing” principle allowed us to optimize the work of the express laboratory, reduce the number of tests, their costs, and increase the quality of research.


2018 ◽  
Vol 31 (2) ◽  
pp. 140-149 ◽  
Author(s):  
Chantal Backman ◽  
Paul C. Hebert ◽  
Alison Jennings ◽  
David Neilipovitz ◽  
Omar Choudhri ◽  
...  

Purpose Patient safety remains a top priority in healthcare. Many organizations have developed systems to monitor and prevent harm, and have invested in different approaches to quality improvement. Despite these organizational efforts to better detect adverse events, efficient resolution of safety problems remains a significant challenge. The authors developed and implemented a comprehensive multimodal patient safety improvement program called SafetyLEAP. The term “LEAP” is an acronym that highlights the three facets of the program including: a Leadership and Engagement approach; Audit and feedback; and a Planned improvement intervention. The purpose of this paper is to evaluate the implementation of the SafetyLEAP program in the intensive care units (ICUs) of three large hospitals. Design/methodology/approach A comparative case study approach was used to compare and contrast the adherence to each component of the SafetyLEAP program. The study was conducted using a convenience sample of three (n=3) ICUs from two provinces. Two reviewers independently evaluated major adherence metrics of the SafetyLEAP program for their completeness. Analysis was performed for each individual case, and across cases. Findings A total of 257 patients were included in the study. Overall, the proportion of the SafetyLEAP tasks completed was 64.47, 100, and 26.32 percent, respectively. ICU nos 1 and 2 were able to identify opportunities for improvement, follow a quality improvement process and demonstrate positive changes in patient safety. The main factors influencing adherence were the engagement of a local champion, competing priorities, and the identification of appropriate resources. Practical implications The SafetyLEAP program allowed for the identification of processes that could result in patient harm in the ICUs. However, the success in improving patient safety was dependent on the engagement of the care teams. Originality/value The authors developed an evidence-based approach to systematically and prospectively detect, improve, and evaluate actions related to patient safety.


2011 ◽  
Vol 32 (1) ◽  
pp. 20-25 ◽  
Author(s):  
Pei-Jean I. Feng ◽  
Alexander J. Kallen ◽  
Katherine Ellingson ◽  
Robert Muder ◽  
Rajiv Jain ◽  
...  

Background.The incidence of methicillin-resistant Staphylococcus aureus (MRSA) colonization or infection has been used as a proxy measure for MRSA transmission, but incidence calculations vary depending on whether active surveillance culture (ASC) data are included.Objective.To evaluate the relationship between incidences of MRSA colonization or infection calculated with and without ASCs in intensive care units and non-intensive care units.Setting.A Veterans Affairs medical center.Methods.From microbiology records, incidences of MRSA colonization or infection were calculated with and without ASC data. Correlation coefficients were calculated for the 2 measures, and Poisson regression was used to model temporal trends. A Poisson interaction model was used to test for differences in incidence trends modeled with and without ASCs.Results.The incidence of MRSA colonization or infection calculated with ASCs was 4.9 times higher than that calculated without ASCs. Correlation coefficients for incidences with and without ASCs were 0.42 for intensive care units, 0.59 for non-intensive care units, and 0.48 hospital-wide. Trends over time for the hospital were similar with and without ASCs (incidence rate ratio with ASCs, 0.95 [95% confidence interval, 0.93-0.97]; incidence rate ratio without ASCs, 0.95 [95% confidence interval, 0.92-0.99]; P = .68). Without ASCs, 35% of prevalent cases were falsely classified as incident.Conclusions.At 1 Veterans Affairs medical center, the incidence of MRSA colonization or infection calculated solely on the basis of clinical culture results commonly misclassified incident cases and underestimated incidence, compared with measures that included ASCs; however, temporal changes were similar. These findings suggest that incidence measured without ASCs may not accurately reflect the magnitude of MRSA transmission but may be useful for monitoring transmission trends over time, a crucial element for evaluating the impact of prevention activities.


Sign in / Sign up

Export Citation Format

Share Document