scholarly journals Real-time Visualization of Breast Carcinoma in Pathology Specimens From Patients Receiving Fluorescent Tumor-Marking Agent Tozuleristide

2018 ◽  
Vol 143 (9) ◽  
pp. 1076-1083 ◽  
Author(s):  
Suzanne M. Dintzis ◽  
Stacey Hansen ◽  
Kristi M. Harrington ◽  
Lennart C. Tan ◽  
Dennis M. Miller ◽  
...  

Context.— Resection of breast carcinoma with adequate margins reduces the risk of local recurrence and reoperation. Tozuleristide (BLZ-100) is an investigational peptide-fluorophore agent that may aid in intraoperative tumor detection and margin assessment. In this study, fluorescence imaging was conducted ex vivo on gross breast pathology specimens. Objectives.— To determine the potential of tozuleristide to detect breast carcinoma in fresh pathology specimens and the feasibility of fluorescence-guided intraoperative pathology assessment of surgical margins. Design.— Twenty-three patients received an intravenous bolus dose of 6 or 12 mg of tozuleristide at least 1 hour before surgery. Fifteen lumpectomy and 12 mastectomy specimens were evaluated for fluorescence by the site's clinical pathology staff using the SIRIS, an investigational near-infrared imaging device. The breast tissue was then processed per usual procedures. Fluorescent patterns were correlated with the corresponding hematoxylin-eosin–stained sections. Clinical pathology reports were used to correlate fluorescent signal to grade, histotype, prognostic marker status, and margin measurements. Results.— Tozuleristide fluorescence was readily observed in invasive and in situ breast carcinoma specimens. Most invasive carcinomas were bright and focal, whereas in situ lesions demonstrated a less intense, more diffuse pattern. Tozuleristide was detected in ductal and lobular carcinomas with a similar fluorescent pattern. Fluorescence was detected in high- and low-grade lesions, and molecular marker/hormone receptor status did not affect signal. Fluorescence could be used to identify the relationship of carcinoma to margins intraoperatively. Conclusions.— Tumor targeting with tozuleristide allowed visual real-time distinction between pathologically confirmed breast carcinoma and normal tissue.

Neurosurgery ◽  
2019 ◽  
Vol 85 (4) ◽  
pp. E641-E649 ◽  
Author(s):  
Chirag G Patil ◽  
David G Walker ◽  
Dennis M Miller ◽  
Pramod Butte ◽  
Beth Morrison ◽  
...  

AbstractBACKGROUNDFluorescence-guided surgery (FGS) can improve extent of resection in gliomas. Tozuleristide (BLZ-100), a near-infrared imaging agent composed of the peptide chlorotoxin and a near-infrared fluorophore indocyanine green, is a candidate molecule for FGS of glioma and other tumor types.OBJECTIVETo perform a phase 1 dose-escalation study to characterize the safety, pharmacokinetics, and fluorescence imaging of tozuleristide in adults with suspected glioma.METHODSPatients received a single intravenous dose of tozuleristide 3 to 29 h before surgery. Fluorescence images of tumor and cavity in Situ before and after resection and of excised tissue ex Vivo were acquired, along with safety and pharmacokinetic measures.RESULTSA total of 17 subjects received doses between 3 and 30 mg. No dose-limiting toxicity was observed, and no reported adverse events were considered related to tozuleristide. At doses of 9 mg and above, the terminal serum half-life for tozuleristide was approximately 30 min. Fluorescence signal was detected in both high- and low-grade glial tumors, with high-grade tumors generally showing greater fluorescence intensity compared to lower grade tumors. In high-grade tumors, signal intensity increased with increased dose levels of tozuleristide, regardless of the time of dosing relative to surgery.CONCLUSIONThese results support the safety of tozuleristide at doses up to 30 mg and suggest that tozuleristide imaging may be useful for FGS of gliomas.


2020 ◽  
pp. 1-1
Author(s):  
Kaiyuan Zheng ◽  
Chuantao Zheng ◽  
Haipeng Zhang ◽  
Junhao Li ◽  
Zidi Liu ◽  
...  

2017 ◽  
Vol T170 ◽  
pp. 014027 ◽  
Author(s):  
A Huber ◽  
D Kinna ◽  
V Huber ◽  
G Arnoux ◽  
I Balboa ◽  
...  

BMC Cancer ◽  
2009 ◽  
Vol 9 (1) ◽  
Author(s):  
Fabíola E Rosa ◽  
Sara M Silveira ◽  
Cássia GT Silveira ◽  
Nádia A Bérgamo ◽  
Francisco A Moraes Neto ◽  
...  

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Jeffrey Dalli ◽  
Eamon Loughman ◽  
Niall Hardy ◽  
Anwesha Sarkar ◽  
Mohammad Faraz Khan ◽  
...  

AbstractAs indocyanine green (ICG) with near-infrared (NIR) endoscopy enhances real-time intraoperative tissue microperfusion appreciation, it may also dynamically reveal neoplasia distinctively from normal tissue especially with video software fluorescence analysis. Colorectal tumours of patients were imaged mucosally following ICG administration (0.25 mg/kg i.v.) using an endo-laparoscopic NIR system (PINPOINT Endoscopic Fluorescence System, Stryker) including immediate, continuous in situ visualization of rectal lesions transanally for up to 20 min. Spot and dynamic temporal fluorescence intensities (FI) were quantified using ImageJ (including videos at one frame/second, fps) and by a bespoke MATLAB® application that provided digitalized video tracking and signal logging at 30fps (Fluorescence Tracker App downloadable via MATLAB® file exchange). Statistical analysis of FI-time plots compared tumours (benign and malignant) against control during FI curve rise, peak and decline from apex. Early kinetic FI signal measurement delineated discriminative temporal signatures from tumours (n = 20, 9 cancers) offering rich data for analysis versus delayed spot measurement (n = 10 cancers). Malignant lesion dynamic curves peaked significantly later with a shallower gradient than normal tissue while benign lesions showed significantly greater and faster intensity drop from apex versus cancer. Automated tracker quantification efficiently expanded manual results and provided algorithmic KNN clustering. Photobleaching appeared clinically irrelevant. Analysis of a continuous stream of intraoperatively acquired early ICG fluorescence data can act as an in situ tumour-identifier with greater detail than later snapshot observation alone. Software quantification of such kinetic signatures may distinguish invasive from non-invasive neoplasia with potential for real-time in silico diagnosis.


2021 ◽  
pp. 130747
Author(s):  
Yanyan Ma ◽  
Yongyuan Liu ◽  
Zike Jiang ◽  
Hongmin Lv ◽  
Jing Wang ◽  
...  