scholarly journals Development and validation of a reverse phase high performance liquid chromatography (HPLC) method for determination of tizanidine in human plasma

2014 ◽  
Vol 8 (7) ◽  
pp. 199-205 ◽  
Author(s):  
Ali Tariq ◽  
Harris Shoaib Muhammad ◽  
Ismail Yousuf Rabia ◽  
Siddiqui Fahad ◽  
Ali Huma ◽  
...  
2020 ◽  
Vol 16 ◽  
Author(s):  
Kemal Hussien Seid ◽  
Tarekegn Berhanu ◽  
Kaleab Asres ◽  
Ayenew Ashenef

Introduction: A reverse-phase high performance liquid chromatography (RP-HPLC) method was developed and validated for the simultaneous analysis of two drugs, levamisole hydrochloride(LH) and oxyclozanide(OX), in co-formulations for veterinary use. Materials and Methods: The new HPLC method was validated per ICH and other guidelines. A C18 column was used with agradient program; eluent A was an equal mixture of methanol and acetonitrile, and eluent B a 25 mM phosphate buffer at pH 7.0 containing 30 mM sodium decanesulfonate andtriethylamine(50:50:1 v/v)then pH adjusted to 7.0 with H3PO4 [51:49 v/v] .The detection wavelength was set at 220 nm.For the final gradient program, the retention times were 8.2(for LH)and 13.6(for OX) minutes respectively at flow rate of 1 ml/min over 20 minute run time. Results: The method wasprecise, specific and robust.The correlation coefficients, R2 were 0.9998 and 0.9999 for LH and OX respectively in the ranges of 5 – 280 µg / mL.The percent y-intercepts and percent residual standard deviations were 1.6%/0.4% and 1.4%/1.0% for LH and OX, respectively. The LOD and LOQ of the method were 0.21 µg / mL and 0.62 µg / mL for LHand 0.06 µg / mL and 0.18 µg / mL for OX. The method has average accuracy of 100.5% for LH and 101.1% for OX when tested on veterinary bolus formulations, and the samples couldbe stored under typical lab conditions for about 7 days without significant degradation. Conclusion: This HPLC method is suitable forassayinglevamisole hydrochloride and oxyclozanide simultaneously from veterinary formulations.


2020 ◽  
Vol 20 (13) ◽  
pp. 1053-1059
Author(s):  
Mahmoud M. Sebaiy ◽  
Noha I. Ziedan

Background: Allergic diseases are considered as the major burden on public health with increased prevalence globally. Histamine H1-receptor antagonists are the foremost commonly used drugs in the treatment of allergic disorders. The target drug in this study, loratadine, belongs to this class of drugs and its biometabolite desloratadine which is also a non-sedating H1 receptor antagonist with anti-histaminic activity being 2.5 to 4 times greater than loratadine. This study aimed to develop and validate a novel isocratic Reversed-phase High-Performance Liquid Chromatography (RP-HPLC) method for rapid and simultaneous separation and determination of loratadine and its metabolite, desloratadine in human plasma. Methods: The drug extraction method from plasma was based on protein precipitation technique. The separation was carried out on a Thermo Scientific BDS Hypersil C18 column (5μm, 250 x 4.60 mm) in a mobile phase of MeOH: 0.025M KH2PO4 adjusted to pH 3.50 using orthophosphoric acid (85: 15, v/v) at an ambient temperature. The flow rate was maintained at 1 mL/min and maximum absorption was measured using the PDA detector at 248 nm. Results: The retention times of loratadine and desloratadine in plasma samples were recorded to be 4.10 and 5.08 minutes, respectively, indicating a short analysis time. Limits of detection were found to be 1.80 and 1.97 ng/mL for loratadine and desloratadine, respectively, showing a high degree of sensitivity of the method. The method was then validated according to FDA guidelines for the determination of the two analytes in human plasma. Conclusion: The results obtained indicate that the proposed method is rapid, sensitive in the nanogram range, accurate, selective, robust and reproducible compared to other reported methods.


2021 ◽  
Vol 0 (0) ◽  
Author(s):  
Katso Binang ◽  
David T. Takuwa

Abstract The aim of the study was to develop a rapid, efficient, and cheap chromatographic method for determining four selected antihypertensive active flavonoid compounds in medicinal plants in Botswana. The determination of rutin, quercetin, and kaempferol in selected medicinal plants was conducted in less than 6 min using the developed reverse phase-high performance liquid chromatography (RP-HPLC) method with a 2.7 µm Ascentis C18 express column (150 × 4.60 mm i.d) at 340, 360, and 368 nm detection wavelengths and mobile phase of methanol and 0.068% of formic acid solution in isocratic elution. Validation results showed good selectivity, linearity (r 2 > 0.99), high percentage recoveries (90.2–104.7%), and precision (% RSD < 2) for n = 3, confirming suitability of the method for determination of the investigated flavonoids in Zingiber officinale (ginger). Application of the developed RP-HPLC method was performed in selected medicinal plants (Lippia javanica ) (mosukujane), Myrothanmus flabellious (galalatshwene), and Elephantorrhiza elephantina (mositsana) used to manage hypertension by herbalists in Botswana. M. flabellious a very commonly used plant for managing hypertension was found to contain highest amounts of rutin and myricetin, whereas nothing was detected for E. elephantina.


1985 ◽  
Vol 4 (6) ◽  
pp. 601-607 ◽  
Author(s):  
M. Žorž ◽  
J. Culig ◽  
Z. Kopitar ◽  
D. Milivojevic ◽  
A. Marušič ◽  
...  

1 Ergot alkaloids and their dihydrogenated methanesulphonate (ms) salts were determined and measured in human plasma. 2 High-performance liquid chromatography (HPLC) with fluorometric detection was used for separation of ergot alkaloids in plasma. 3 Several ergot alkaloids and their derivatives, including lysergide (LSD), can be identified in cases of poisoning.


Author(s):  
Bijithra Cholaraja ◽  
Shanmugasundaram P ◽  
Ragan G ◽  
Sankar Ask ◽  
Sumithra M

ABSTRACTObjective: To development and validation of a reversed-phase high-performance liquid chromatography (RP-HPLC) for the determination of modafinilin bulk and pharmaceutical dosage forms.Methods: A simple, precise, rapid, and accurate RP-HPLC method was developed for the estimation of modafinil in bulk and pharmaceutical dosageforms. Xterra RP 18 (250 mm × 4.6 mm, 5 µ particle size) with a mobile phase consisting of methanol:water 70:30 V/V was used. The flow rate1.0 ml/min and the effluents were monitored at 260 nm. The retention time and recovery time was 12 minutes. The detector response was linear inthe concentration of 10-50 µg/ml. The respective linear regression equation being Y=452.1x+65237. The limit of detection and limit of quantificationwere 4.547 and 1.377 mcg, respectively. The method was validated by determining its accuracy, precision, and system suitability.Result: The objective of the present work is to develop simple, precise, and reliable HPLC method for the analysis of modafinil in bulk andpharmaceutical dosage forms. This is achieved using the most commonly employed Xterra RP 18 (250 mm × 4.6 mm, 5 μ particle size) columndetection at 260 nm. The present method was validated according to ICH guidelines.Conclusion: In this study, a simple, fast and reliable HPLC method was developed and validated for the determination of modafinil in pharmaceuticalformulations.Keywords: Modafinil, Reversed-phase high-performance liquid chromatography, Estimation, ICH guidelines, Tablets. 


Sign in / Sign up

Export Citation Format

Share Document