An Experimental Study on Performance of Energy Recovery Ventilation System

2012 ◽  
Vol 36 (4) ◽  
pp. 445-450
Author(s):  
Young-Soo Kim ◽  
Kwan-Soo Choi ◽  
Il-Soo Kim
Energy ◽  
2021 ◽  
pp. 122550
Author(s):  
Zhen Tian ◽  
Wanlong Gan ◽  
Zhixin Qi ◽  
Molin Tian ◽  
Wenzhong Gao

2018 ◽  
Vol 152 ◽  
pp. 431-437 ◽  
Author(s):  
Han Fengxia ◽  
Zhang Zhongbin ◽  
Huang Hu ◽  
Chen Zemin

2018 ◽  
Vol 9 (1) ◽  
pp. 49-57
Author(s):  
L. F. Al-Hyari ◽  
M. Kassai

The statistical data show that the application of active cooling is spread widely in residential and commercial buildings. In these buildings, the ventilation is significantly increased in the whole energy consumption. There are similar problems in the operation of post-insulation of existing buildings. In this case, the energy consumption of the ventilation system gives a major proportion of the whole building services energy consumption. The opportuneness of this research shows that the actual available calculation procedures and technical designing data are only rough approximations for analyzing the energy consumption of air handling units and the energy saved by the integrated heat or energy recovery units. There are not exact methods and unequivocal technical data. In previous researches, the production and development companies have not investigated the effectiveness of the energy recovery units under difference ambient air conditions and the period of defrost cycle when the heat recovery can only partly operate under difference ambient air temperatures. During this term, a re-heater has to fully heat up the ambient cold air to the temperature of supplied air and generate the required heating demand to provide the necessary indoor air temperature.


2018 ◽  
Vol 240 ◽  
pp. 02003 ◽  
Author(s):  
Marek Borowski ◽  
Marek Jaszczur ◽  
Daniel Satoła ◽  
Sławosz Kleszcz ◽  
Michał Karch

Heating, ventilation and air conditioning systems are responsible for a nearly 50% of total energy consumption in operated buildings. One of the most important parts of the ventilation system is an air handling unit with a heat exchanger for energy recovery which is responsible for effective and efficient energy recovery from exhaust air. Typically heat exchangers are characterised by the producers by heat and humidity recovery efficiency up to 90% and 75% respectively. But these very high values are usually evaluated under laboratory conditions without taking into account a dynamic change of outdoor and indoor air conditions significantly affecting the recovery efficiency. In this paper, results of thermal, humidity and enthalpy recover efficiency of innovative energy recovery exchanger have been presented. The analysed system allows adjustment of the humidity recovery especially useful in the winter period and forefends energy use for an anti-froze system of energy exchanger. Presented result show that analysed innovative system can achieve the value of thermal efficiency recovery higher than 90% and efficiency of humidity recovery about 80%. This is possible because the analysed system is able to work without the use of any primary source energy or other anti-freeze systems. Presented in this research unique solution is able to work without external anti-freeze systems even in extremely adverse outdoor air conditions such as minus 20°C and humidity 100% RH.


2014 ◽  
Vol 644-650 ◽  
pp. 377-380
Author(s):  
Yi Ping Lu ◽  
Qing Hui Pan ◽  
Hui Lan Li ◽  
Jia De Han

To study rotational air flow field of rotor and complicated flow distinction owing to multi-ventilation ducts of stator in a large air-cooled turbine generator, considering axial symmetry of air supply, an experiment setup of ventilation system of semi-machine configuration was built in this paper. At condition of rotating, ventilation is measured by hot-wire anemometer. Firstly, ventilation in 16 different semi-circle radius is got. Measurement shows that ventilation in different radius varies much. Then ventilation of outlet of stator ducts is measured. The result shows that ventilation which is affected by flow back and jet less is higher. The conclusion will provide theoretical references for ventilation cooling of rotor ducts in large air-cooled turbine generators.


2003 ◽  
Vol 35 (10) ◽  
pp. 1021-1030 ◽  
Author(s):  
Francisco Javier Rey Martı́nez ◽  
Mario Antonio Álvarez-Guerra Plasencia ◽  
Eloy Velasco Gómez ◽  
Fernando Varela Dı́ez ◽  
Ruth Herrero Martı́n

Sign in / Sign up

Export Citation Format

Share Document