scholarly journals Integrated Numerical Modeling of Surface-Subsurface-Coupled, 2-Phase Fluid/Heat Flow in Limnological System No. 1 New Type of Modeling and Experimental Study

1999 ◽  
Vol 41 (3) ◽  
pp. 147-158 ◽  
Author(s):  
Hiroyuki TOSAKA ◽  
Akira ITOH ◽  
Masaki TANAKA ◽  
Taku IWAI
Energies ◽  
2021 ◽  
Vol 14 (3) ◽  
pp. 748
Author(s):  
Xiaoyan Bian ◽  
Yao Zhang ◽  
Qibin Zhou ◽  
Ting Cao ◽  
Bengang Wei

Building Integrated Photovoltaic (BIPV) modules are a new type of photovoltaic (PV) modules that are widely used in distributed PV stations on the roof of buildings for power generation. Due to the high installation location, BIPV modules suffer from lightning hazard greatly. In order to evaluate the risk of lightning stroke and consequent damage to BIPV modules, the studies on the lightning attachment characteristics and the lightning energy withstand capability are conducted, respectively, based on numerical and experimental methods in this paper. In the study of lightning attachment characteristics, the numerical simulation results show that it is easier for the charges to concentrate on the upper edge of the BIPV metal frame. Therefore, the electric field strength at the upper edge is enhanced to emit upward leaders and attract the lightning downward leaders. The conclusion is verified through the long-gap discharge experiment in a high voltage lab. From the experimental study of multi-discharge in the lab, it is found that the lightning interception efficiency of the BIPV module is improved by 114% compared with the traditional PV modules. In the study of lightning energy withstand capability, a thermoelectric coupling model is established. With this model, the potential, current and temperature can be calculated in the multi-physical field numerical simulation. The results show that the maximum temperature of the metal frame increases by 16.07 °C when 100 kA lightning current flows through it and does not bring any damage to the PV modules. The numerical results have a good consistency with the experimental study results obtained from the 100 kA impulse current experiment in the lab.


Silicon ◽  
2021 ◽  
Author(s):  
Huawei Song ◽  
Pengfei Pan ◽  
Kaihua Xu ◽  
Yuping Zhang ◽  
Zhengxin Yang ◽  
...  

Author(s):  
Andrea Opreni ◽  
Attilio Frangi ◽  
Nicolo Boni ◽  
Gianluca Mendicino ◽  
Massimiliano Merli ◽  
...  

ICCTP 2010 ◽  
2010 ◽  
Author(s):  
Hua Zang ◽  
Zhao Liu ◽  
Yong-ming Tu ◽  
Yun-mei Meng

2003 ◽  
pp. 135-144
Author(s):  
Zhaoyu YANG ◽  
Teruyuki SUZUKI ◽  
Seigo SAWADA ◽  
Satoshi YAMASHITA
Keyword(s):  

AIP Advances ◽  
2021 ◽  
Vol 11 (9) ◽  
pp. 099901
Author(s):  
Yi Zhang ◽  
Qiyu Chen ◽  
Wei Zhang ◽  
Zhiying Lu ◽  
Youbao Ma ◽  
...  

2013 ◽  
Vol 409-410 ◽  
pp. 668-672
Author(s):  
Yong Mei Xu ◽  
Jian Tang ◽  
Jun Han ◽  
Chu Qin Lin

Aimed at a new type of ventilation - stratum ventilation, air distributions at a breathing-zone in a model office were measured under kinds of air changes, the measure parameters in the experimental studies included temperatures, wind speeds and pollutant concentrations, based on which the thermal comfort at a breathing-zone were studied. Experimental results show that, the temperature, pollutant concentration and wind speeds in a breathing-zone under 5 times air changes are better than those under 6 times air changes. The calculating results of PMV and PPD indicate that the thermal comfort at a breathing-zone under 5 times air changes is better. The experimental study is instructive for the development of the ventilation.


Sign in / Sign up

Export Citation Format

Share Document