scholarly journals Erratum: “Experimental study on dynamic and static performance of a new type of pressure-absorbing energy bolt system” [AIP Adv. 11, 075124 (2021)]

AIP Advances ◽  
2021 ◽  
Vol 11 (9) ◽  
pp. 099901
Author(s):  
Yi Zhang ◽  
Qiyu Chen ◽  
Wei Zhang ◽  
Zhiying Lu ◽  
Youbao Ma ◽  
...  
AIP Advances ◽  
2021 ◽  
Vol 11 (7) ◽  
pp. 075124
Author(s):  
Yi Zhang ◽  
Qiyu Chen ◽  
Wei Zhang ◽  
Youbao Ma ◽  
Sibo Zhang ◽  
...  

Energies ◽  
2021 ◽  
Vol 14 (3) ◽  
pp. 748
Author(s):  
Xiaoyan Bian ◽  
Yao Zhang ◽  
Qibin Zhou ◽  
Ting Cao ◽  
Bengang Wei

Building Integrated Photovoltaic (BIPV) modules are a new type of photovoltaic (PV) modules that are widely used in distributed PV stations on the roof of buildings for power generation. Due to the high installation location, BIPV modules suffer from lightning hazard greatly. In order to evaluate the risk of lightning stroke and consequent damage to BIPV modules, the studies on the lightning attachment characteristics and the lightning energy withstand capability are conducted, respectively, based on numerical and experimental methods in this paper. In the study of lightning attachment characteristics, the numerical simulation results show that it is easier for the charges to concentrate on the upper edge of the BIPV metal frame. Therefore, the electric field strength at the upper edge is enhanced to emit upward leaders and attract the lightning downward leaders. The conclusion is verified through the long-gap discharge experiment in a high voltage lab. From the experimental study of multi-discharge in the lab, it is found that the lightning interception efficiency of the BIPV module is improved by 114% compared with the traditional PV modules. In the study of lightning energy withstand capability, a thermoelectric coupling model is established. With this model, the potential, current and temperature can be calculated in the multi-physical field numerical simulation. The results show that the maximum temperature of the metal frame increases by 16.07 °C when 100 kA lightning current flows through it and does not bring any damage to the PV modules. The numerical results have a good consistency with the experimental study results obtained from the 100 kA impulse current experiment in the lab.


2021 ◽  
Vol 36 (1) ◽  
pp. 67-77
Author(s):  
Yue Wu ◽  
Junkai Huang ◽  
Jiafeng Chen

The long-span ice composite shell structure is a new type of ice and snow structure developed in recent years. The engineering practice of ice composite shell shows that sublimation is one of the important reasons for its damage and even collapse. In this paper, we firstly supplemented the existing H-K equation and obtained the revised ice sublimation equation through indoor evaporative plate experiment considering the influence of admixtures and wind speed. Afterwards, combining the simulations of solar radiation and CFD, the numerical simulation of sublimation distribution on the surface of were realized by programming in Grasshopper platform. During sublimation, the thickness of the ice composite shell decreases by 0.38 mm every 10 days and the sublimation rate on the sunny side was 1.7 times that on the shady side. Finally, the static performance and stability of the sublimated ice composite spherical shell were analyzed. After 70 days of sublimation, the thickness of the ice composite shell structure becomes thinner and uneven, which leads its sensitivity to external load increases.


ICCTP 2010 ◽  
2010 ◽  
Author(s):  
Hua Zang ◽  
Zhao Liu ◽  
Yong-ming Tu ◽  
Yun-mei Meng

2013 ◽  
Vol 409-410 ◽  
pp. 668-672
Author(s):  
Yong Mei Xu ◽  
Jian Tang ◽  
Jun Han ◽  
Chu Qin Lin

Aimed at a new type of ventilation - stratum ventilation, air distributions at a breathing-zone in a model office were measured under kinds of air changes, the measure parameters in the experimental studies included temperatures, wind speeds and pollutant concentrations, based on which the thermal comfort at a breathing-zone were studied. Experimental results show that, the temperature, pollutant concentration and wind speeds in a breathing-zone under 5 times air changes are better than those under 6 times air changes. The calculating results of PMV and PPD indicate that the thermal comfort at a breathing-zone under 5 times air changes is better. The experimental study is instructive for the development of the ventilation.


2020 ◽  
Vol 25 (3) ◽  
pp. 9-16
Author(s):  
Gwon-Seok Sun

Frosting on the surface of a heat exchanger degrades its cooling efficiency in a cooling system. In this study, frost flow analysis is performed for frost reduction. A new type of air blast refrigerator is designed for reducing frost formation in its finned tube. Experimental results of the frost formation in the air blast refrigerator are presented. The main difference between the proposed and conventional air blast refrigerators is the flow of air through the finned tube. The proposed refrigerator produces less frost than the conventional refrigerators.


2013 ◽  
Vol 431 ◽  
pp. 88-92
Author(s):  
Ai Dong Zhang ◽  
Ri Cheng Xu ◽  
Yun Meng ◽  
Xun Fan

Water cushion belt conveyor is a new type of continuous conveyor which develops from belt conveyor and air cushion belt conveyor .By experimental research on water cushion belt conveyor ,we can observe the condition of water cushion and accomplish the date acquisition of water cushion pressure .Analyzing the pressure ,we can get influencing factors of water cushion pressure and verify the feasibility of industrial application of water cushion belt conveyor .Combining theory study with experimental study ,provide theoretical basis and guide for the further progress of water cushion belt conveyor .


Energies ◽  
2020 ◽  
Vol 13 (20) ◽  
pp. 5356
Author(s):  
Hamdy Mansour ◽  
Rola Afify

The IceWind turbine, a new type of Vertical Axis Wind Turbine, was proposed by an Iceland based startup. It is a product that has been featured in few published scientific research studies. This paper investigates the IceWind turbine’s performance numerically. Three-dimensional numerical simulations are conducted for the full scale model using the SST K-ω model at a wind speed of 15.8 m/s. The following results are documented: static torque, velocity distributions and streamlines, and pressure distribution. Comparisons with previous data are established. Additionally, comparisons with the Savonius wind turbine in the same swept area are conducted to determine how efficient the new type of turbine is. The IceWind turbine shows a similar level of performance with slightly higher static torque values. Vortices behind the IceWind turbine are confirmed to be three-dimensional and are larger than those of Savonius turbine.


Sign in / Sign up

Export Citation Format

Share Document