RP-hplc method validation for quantitative analysis of pemetrexed disodium hemipentahydrate

2020 ◽  
Vol 13 (8) ◽  
pp. 3685
Author(s):  
Vitthal M. Dhalape ◽  
Santosh T. Khadangale ◽  
Rahul V. Pinjari
Author(s):  
MADHURIMA BASAK ◽  
Santhosh Reddy Gouru ◽  
Animesh Bera ◽  
Krishna veni Nagappan

Objective: The present study aims at developing an accurate precise, rapid and sensitive Reverse Phase High-Performance Liquid Chromatography (RP-HPLC) method for assessing Empagliflozin in bulk drug and in the pharmaceutical dosage form. Methods: The proposed method employs a Reverse Phase Shim Pack C18 column (250 mm × 4.6 mm id; 5 µm) using a mobile phase comprising of acetonitrile and water in the ratio of 60:40 v/v flushed at a flow rate of 1 ml/min. The eluents were monitored at 223 nm. Results: Empagliflozin was eluted at a retention time of 5.417 min and established a co-relation co-efficient (R2>0.999) over a concentration ranging from 0.0495-100µg/ml. Percentage recovery was obtained between 98-102% which indicated that the method is accurate. The Limit of Detection (LOD) and Limit of Quantitation (LOQ) were found at 0.0125µg/ml and 0.0495µg/ml, respectively. Conclusion: An RP-HPLC method which was relatively simple, accurate, rapid and precise was developed and its validation was performed for the quantitative analysis of empagliflozin in bulk and tablet dosage form (10 and 25 mg) in accordance to International Conference of Harmonization (ICH) Q2 (R1) guidelines. The proposed method may aid in routinely analyzing empagliflozin in pharmaceuticals.


2019 ◽  
Vol 57 (7) ◽  
pp. 636-643 ◽  
Author(s):  
Aya A Youssef ◽  
N Magdy ◽  
Lobna A Hussein ◽  
A M El-Kosasy

Abstract Egypt has the highest prevalence of hepatitis C virus (HCV) in the world thus it launched a national program for eliminating HCV aiming to treat 300,000 HCV patients per year. Three anti-HCV co-administered drugs; ribavirin (RBV), sofosbuvir (SF) daclatasvir (DAC) were simultaneously determined in human plasma by a validated, simple and sensitive RP-HPLC method using propyl paraben as an internal standard. Liquid–liquid extraction using ethyl acetate was used for samples extraction. Chromatographic separation was achieved on Scharlau® C18 column (250 × 4.6 mm2, 5 μm). Gradient elution was employed with a mobile phase mixture of water and acetonitrile at a flow rate 1 mL/min. UV detection using photodiode array detector was carried out at 207, 260 and 312 nm for RBV, SF and DAC, respectively. Method validation was performed according to the FDA guidelines for bioanalytical method validation. The calibration curves were linear over the ranges (0.5–80, 0.1–40 and 0.5–80 μg/mL) with average recoveries (100.64–108.28%, 98.48–105.91% and 97.68–101.38%) for RBV, SF and DAC, respectively. The intra-day and inter-day precision and accuracy results were within the acceptable limits. Stability assays revealed that the three studied analytes were stable during sample storage, preparation and injection. The method can be successfully applied in routine analysis of plasma of HCV patients treated with this combination therapy which aids in therapeutic drug monitoring and patients’ follow-up especially in Egypt and other developing countries fighting HCV.


2018 ◽  
Vol 07 (01) ◽  
Author(s):  
Md Didarul Md Didarul Islam ◽  
Mehedi Hasan M ◽  
Mohiuddin TM ◽  
Md Mynul Hassan ◽  
Asheful Latif ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document