scholarly journals Assessment of First Generation Performance-Based Seismic Design Methods for New Steel Buildings, Volume 3: Eccentrically Braced Frames

Author(s):  
John L. Harris III ◽  
Matthew S. Speicher
2014 ◽  
Vol 30 (4) ◽  
pp. 1683-1709 ◽  
Author(s):  
Edgar Tapia-Hernández ◽  
Arturo Tena-Colunga

In order to help improve the seismic design of regular steel buildings structured with ductile moment-resisting concentrically braced frames (MRCBFs) using the general design methodology of Mexico's Federal District Code (MFDC-04), suitable design parameters were first assessed using the results of pushover analyses of 13 regular MRCBFs. In order to insure collapse mechanisms consistent with the assumptions implicit in a code-based design (strong-column/weak-beam/weaker-brace), it is proposed to relate the minimum strength ratio for the resisting columns of the moment frames and the bracing system. Improved equations are proposed for a more realistic assessment of ductility and overstrength factors. In a second stage, the effectiveness of the improved methodology was assessed with the design of six regular steel buildings with MRCBFs. Buildings were evaluated by performing both pushover and nonlinear time-history analyses under ten selected artificial ground motions related to the corresponding design spectrum.


2013 ◽  
Vol 29 (1_suppl) ◽  
pp. 219-243 ◽  
Author(s):  
Taichiro Okazaki ◽  
Dimitrios G. Lignos ◽  
Mitsumasa Midorikawa ◽  
James M. Ricles ◽  
Jay Love

A joint U.S.–Japan reconnaissance team examined the damage to steel building structures caused by the 2011 Tohoku-oki earthquake. In the city of Sendai, where the peak horizontal ground acceleration exceeded 1 g, the majority of steel buildings performed well. Buildings that used older cladding systems for external finish sustained damage to their claddings even if their structural performance was excellent. Damage to a few braced frames offer insight into the seismic design of bracing connections. In areas attacked by the violent tsunami, many steel buildings stood upright after the tsunami subsided, although these buildings lost much of their external and internal finishes along with their contents. These steel buildings did not provide safe shelter for tsunami evacuation when the building submerged under the tsunami wave. A number of buildings suffered foundation failure, which was likely caused by scouring or liquefaction or a combination of multiple effects.


Sign in / Sign up

Export Citation Format

Share Document