scholarly journals Stability-Indicating HPLC Methods for the Quantification of Cyproheptadine Hydrochloride, Vitamins B1, B5 And B6 in Tablets using RP-HPLC with UV Detection

2020 ◽  
Author(s):  
KANCHARLA VIJAYALAKSHMI ◽  
BETHAPUDI SAMUEL ANAND ANDREWS ◽  
BOLINENI NAGESWARA RAO

Objective: We have developed a “stability-indicating RP-HPLC” procedure for the Bilastine (BLS) and montelukast (MTL) analysis of tablets. Methods: The quantification of BLS and MTL combination was implemented utilising a Waters column (C18, 5 μm, 250 mm and 4.6 mm). Isocratic mobile phase had 60% volume KH2PO4 of 0.1M strength with pH 4.2 units and 40% volume methanol at a flow with 1.0 ml/min speed. UV detection at 232 nm was done to examine BLS and MTL. Stability experiments of BLS and MTL under distinctive environments of stress were also performed. Results: The BLS and MTL were eluted at 1.810 min and 2.551 min, respectively. The responses were found to be linear for the concentration ranges of 10-30 µg/ml (BLS) and 5-15 µg/ml (MTL). Percent comparative standard deviance for precision was 0.331% (BLS) and 0.486% (MTL). Percent assay for accuracy was 98.96% (BLS) and 99.00% (MTL). The detection limit and quantitation limit measures for BLS were 0.018 µg/ml and 0.059 µg/ml, respectively, while for MTL it was 0.024 µg/ml and 0.081 µg/ml, respectively. Robustness studies authorized that the method is robust with percent comparative standard deviance of a highest 1.950%. Conclusion: The developed “stability-indicating RP-HPLC” procedure for the BLS and MTL analysis is simple, sensitive, precise, specific and robust, making it appropriate to the assessment of BLS and MTL in a tablet formulation.


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
J. Saroja ◽  
Anantha Lakshmi P.V. ◽  
Y. Rammohan ◽  
D. Divya Reddy

Abstract Background We describe a “stability-indicating liquid chromatography” technique for the estimation of dimethicone (DEC) and dicyclomine hydrochloride (DEH) in the established tablet formulations. Individual quantification of DEH and DEC was reported. But simultaneous quantification of DEH and DEC was lacking. DEH and DEC were analysed on an “XTerra C18 column (250 mm × 4.6 mm, 5 μm)” with the mobile phase solvent run isocratically with 0.1M K2HPO4-acetonitrile (55:45, v/v) on a flow speed of 1.0 mL/min. Results The chromatographic run period for the DEC and DEH assay was 6.0 min with retention times of 2.134 and 2.865 min, respectively. The method was validated for accuracy (99.453 to 100.417% and 99.703 to 100.303% recovery values for DEH and DEC, respectively), precision (RSV value 0.135% for DEC and 0.171% for DEH), linearity (5–15 μg/mL for DEH and 20–60 μg/mL for DEC), selectivity (no hinderance from excipients) and specificity (no hinderance from degradants) recovery. Conclusion The developed stability-indicating liquid chromatography process was well applied to established tablet formulations.


2020 ◽  
Vol 18 (1) ◽  
pp. 377-390
Author(s):  
Dina El Sherbiny ◽  
Mary E. K. Wahba

AbstractA stability-indicating hybrid micelle liquid chromatography accompanied by UV detection was developed for the simultaneous analysis of either paracetamol (PCA) or pseudoephedrine hydrochloride (PSU) with their synthetic impurities. Mixture I contains PCA with p-amino phenol and p-nitro phenol, while mixture II involves the estimation of PSU with benzaldehyde and benzoic acid. Both mixtures were separated using a C18 column that was thermostatically maintained at 40°C and operating under a flow rate of 1.5 mL/min, applying UV detection at 240 nm for mixture I and 220 nm for mixture II. In both cases, the mobile phase consisted of 0.1 M sodium dodecyl sulfate, acetonitrile, and triethylamine (90:10:0.3, v/v/v) and adjusted to pH 4 (mixture I) or pH 3.7 (mixture II) using 2.0 M O-phosphoric acid. The proposed method was validated and successfully applied to assay different pharmaceuticals containing PCA or PSU. Moreover, the stability-indicating nature of the proposed method was proved through applying photolytic degradation procedures for PCA.


Sign in / Sign up

Export Citation Format

Share Document