scholarly journals Low enthalpy geothermal energy: borehole heat exchangers (BHE). Geological and geothermal supervision during active construction in support of the energy certification of buildings - ESBE certification plan

Author(s):  
Lorenzo Cadrobbi ◽  
Fioroni Daniele ◽  
Alessandro Bozzoli

This article draws on the experience matured while working with low-enthalpy geothermic installations both in the design and executive phase as well as ongoing monitoring, within the scope of energy conservation as it relates to building and construction. The goal is to illustrate the feasibility of adopting the ESBE certification protocol (Certification of Energy Efficient Low-Enthalpy Probes) aimed at optimizing the harnessing of local geothermic resources to satisfy the energy requirements of a building, measured against the initial investment. It is often the case, in fact, that during the course of a construction project for a given low-enthalpy installation, we verify incompa tibilities with the local geologic and geothermic models, which, if inadequate during construction, can compromise the proper functioning of the installation and its subsequent operation. To this end, the ESBE method, which adheres to the governing environmental regulations, and which takes its cue from technical statutes within the sector, permits us to validate via verification, simulations and tests, the geothermic field probes used in construction in an objective and standardized manner, thereby joining and supporting the most recent protocols for energy certification of buildings (LEED 2010, CASACLIMA 2011, UE 20120/31 Directive). ESBE certification operates through a dedicated Certifying Entity represented by the REET unit (Renewable Energies and Environmental Technologies) of FBK (Bruno Kessler Foundation) of Trento. The results obtained by applying the ESBE method to two concrete cases, relative to two complex geothermic systems, demonstrate how this protocol is able to guarantee, beyond the correct execution in the field of geothermic probes, an effective coverage of the energy requirements of the building during construction adopting the best optimization measures for the probes in keeping with the local geological and geothermic model.

Energies ◽  
2021 ◽  
Vol 14 (16) ◽  
pp. 5119
Author(s):  
Tomasz Sliwa ◽  
Tomasz Kowalski ◽  
Dominik Cekus ◽  
Aneta Sapińska-Śliwa

Currently, renewable energy is increasingly important in the energy sector. One of the so-called renewable energy sources is geothermal energy. The most popular solution implemented by both small and large customers is the consumption of low-temperature geothermal energy using borehole heat exchanger (BHE) systems assisted by geothermal heat pumps. Such an installation can operate regardless of geological conditions, which makes it extremely universal. Borehole heat exchangers are the most important elements of this system, as their design determines the efficiency of the entire heating or heating-and-cooling system. Filling/sealing slurry is amongst the crucial structural elements. In borehole exchangers, reaching the highest possible thermal conductivity of the cement slurry endeavors to improve heat transfer between the rock mass and the heat carrier. The article presents a proposed design for such a sealing slurry. Powdered magnesium was used as an additive to the cement. The approximate cost of powdered magnesium is PLN 70–90 per kg (EUR 15–20/kg). Six different slurry formulations were tested. Magnesium flakes were used in designs A, B, C, and magnesium shavings in D, E and F. The samples differed in the powdered magnesium content BWOC (by weight of cement). The parameters of fresh and hardened sealing slurries were tested, focusing mainly on the thermal conductivity parameter. The highest thermal conductivity values were obtained in design C with the 45% addition of magnesium flakes BWOC.


Energies ◽  
2020 ◽  
Vol 13 (3) ◽  
pp. 754 ◽  
Author(s):  
Jiewen Deng ◽  
Qingpeng Wei ◽  
Shi He ◽  
Mei Liang ◽  
Hui Zhang

Deep borehole heat exchangers (DBHEs) extract heat from the medium-depth geothermal energy with the depth of 2–3 km and provide high-temperature heat source for the medium-depth geothermal heat pump systems (MD-GHPs). This paper focuses on the heat transfer performance of DBHEs, where field tests and simulation are conducted to analyze the heat transfer process and the influence factors. Results identify that the heat transfer performance is greatly influenced by geothermal properties of the ground, thermal properties and depth of DBHEs and operation parameters, which could be classified into external factors, internal factors and synergic adjustment. In addition, the long-term operation effects are analyzed with the simulation, results show that with inlet water temperature setting at 20 °C and flow rate setting at 6.0 kg/s, the average outlet water temperature only drops 0.99 °C and the average heat extraction drops 9.5% after 20-years operation. Therefore, it demonstrates that the medium-depth geothermal energy can serve as the high-temperature heat source for heat pump systems stably and reliably. The results from this study can be potentially used to guide the system design and optimization of DBHEs.


2017 ◽  
Vol 21 ◽  
pp. 437-444 ◽  
Author(s):  
Raluca Paula Moldovan ◽  
Gheorghe Viorel Dragoș ◽  
Marina Verdeș ◽  
Vasilică Ciocan ◽  
Marius Costel Bălan ◽  
...  

Within the present context of the effects of climate changes upon the environment, social and economic framework, but also of the trend of population growth and urban development, ensuring a sustainable, competitive and secure energy development will be possible, primarily, by reducing the negative impact of buildings upon the environment, improving energetic and ecological performances of systems and buildings envelope and promoting renewable sources of energy. In this sense, the paper analyzes, in dynamic simulation regime, performant solutions to reduce the energy consumption for heating energy efficient buildings and greenhouse gas emissions, by harnessing geothermal energy through the use of heat pumps and earth-to-air heat exchangers. The case study starts from an energy efficient building, analyzing the dynamic thermal behavior of the building and then various configurations of earth-to-air heat exchangers in terms of heating potential. For the selection of the optimum solution in terms of coverage of the heating energy demand, different systems combining heat pumps and earth-to-air heat exchangers are studied.


2021 ◽  
Vol 237 ◽  
pp. 110794
Author(s):  
Wenke Zhang ◽  
Jianhua Wang ◽  
Fangfang Zhang ◽  
Wei Lu ◽  
Ping Cui ◽  
...  

2016 ◽  
Vol 41 ◽  
pp. 268-271
Author(s):  
Luca Alberti ◽  
Adriana Angelotti ◽  
Matteo Antelmi ◽  
Ivana La Licata