scholarly journals Nebulized dexmedetomidine improves pulmonary shunt and lung mechanics during one-lung ventilation: a randomized clinical controlled trial

PeerJ ◽  
2020 ◽  
Vol 8 ◽  
pp. e9247
Author(s):  
Bo Xu ◽  
Hong Gao ◽  
Dan Li ◽  
Chunxiao Hu ◽  
Jianping Yang

Background Dexmedetomidine (Dex), a selective a2-adrenergic receptor agonist, has been previously reported to attenuate intrapulmonary shunt during one-lung ventilation (OLV) and to alleviate bronchoconstriction. However, the therapeutic effects of nebulized Dex on pulmonary shunt and lung mechanics during OLV have not been evaluated. Here we determine whether nebulized dexmedetomidine improved pulmonary shunt and lung mechanics in patients undergoing elective thoracic surgery in a prospective randomized controlled clinical trial. Methods One hundred and twenty-eight patients undergoing elective thoracoscopic surgery were included in this study and randomly divided into four groups: 0.9% saline (Placebo group), 0.5 µg/kg (Dex0.5 group), 1 µg/kg (Dex1 group) and 2 µg/kg (Dex2group) dexmedetomidine. After bronchial intubation, patients received different nebulized doses of dexmedetomidine (0.5 µg/kg, 1 µg/kg and 2 µg/kg) or 0.9% saline placebo during two-lung ventilation(TLV). OLV was initiated 15 min after bronchial intubation. Anesthesia was maintained with intravenous infusion of cisatracurium and propofol. Bispectral Index values were maintained within 40–50 by adjusting the infusion of propofol in all groups. Arterial blood gas samples and central venous blood gas samples were taken as follows: 15 min after bronchial intubation during two-lung ventilation (TLV15), after 30 and 60 min of OLV (OLV30and OLV60, respectively) and 15 min after reinstitution of TLV (ReTLV). Dynamic compliance was also calculated at TLV15, OLV30, OLV60 and ReTLV. Results Dex decreased the requirement of propofol in a dose-dependent manner(P = 0.000). Heart rate (HR) and mean arterial pressure (MAP) displayed no significant difference among groups (P = 0.397 and 0.863). Compared with the placebo group, Dex administered between 0.5 and 2 µg/kg increased partial pressure of oxygen (PaO2) significantly at OLV30 and OLV60(P = 0.000); however, Dex administered between 1 and 2 µg/kg decreased pulmonary shunt fraction (Qs/Qt) at OLV30 and OLV60(P = 0.000). Compared with the placebo group, there were significant increases with dynamic compliance (Cdyn) after OLV in Dex0.5, Dex1 and Dex2group(P = 0.000). Conclusions. Nebulized dexmedetomidine improved oxygenation not only by decreasing pulmonary shunt but also by improving lung compliance during OLV, which may be effective in managing OLV.

2022 ◽  
Vol 22 (1) ◽  
Author(s):  
Pengyi Li ◽  
Lianbing Gu ◽  
Jing Tan ◽  
Zhenghuan Song ◽  
Qingming Bian ◽  
...  

Abstract Background Prostaglandin E1 (PGE1) has been reported to maintain adequate oxygenation among patients under 60% FiO2 one-lung ventilation (OLV). This research aimed to explore whether PGE1 is safe in pulmonary shunt and oxygenation under 40% FiO2 OLV and provide a reference concentration of PGE1. Methods Totally 90 esophageal cancer patients treated with thoracotomy were enrolled in this study, randomly divided into three groups (n = 30/group): Group A (60% FiO2 and 0.1 µg/kg PGE1), Group B (40% FiO2 and 0.1 µg/kg PGE1), and Group C (40% FiO2, 0.2 µg/kg PGE1). Primary outcomes were oxygenation and pulmonary shunt during OLV. Secondary outcomes included oxidative stress after OLV. Results During OLV, patients in Group C and B had lower levels of PaO2, SaO2, SpO2, MAP, and Qs/Qt than those in Group A (P < 0.05). At T2 (OLV 10 min), patients in Group C and B exhibited a lower level of PaO2/FiO2 than those in Group A, without any statistical difference at other time points. The IL-6 levels of patients in different groups were different at T8 (F = 3.431, P = 0.038), with IL-6 in Group C being lower than that in Group B and A. MDA levels among the three groups differed at T5 (F = 4.692, P = 0.012) and T7 (F = 5.906, P = 0.004), with the MDA level of Group C being lower than that of Group B and A at T5, and the MDA level of Group C and B being lower than that of Group A at T7. In terms of TNF-α level, patients in Group C had a lower level than those in Group B and A at T8 (F = 3.598, P = 0.033). Compared with patients who did not use PGE1, patients in Group C had comparable complications and lung infection scores. Conclusion The concentration of FiO2 could be reduced from 60 to 40% to maintain oxygenation. 40% FiO2 + 0.2 µg/kg PGE1 is recommended as a better combination on account of its effects on the inflammatory factors. Trial registration: Chictr.org.cn identifier: ChiCTR1800018288, 09/09/2018.


1994 ◽  
Vol 27 (4) ◽  
pp. 381
Author(s):  
Su Won Kim ◽  
Byung Young Kim ◽  
Myoung Hoon Kong ◽  
Hae Ja Lim ◽  
Byung Kook Chae ◽  
...  

1972 ◽  
Vol 6 (2) ◽  
pp. 189-198 ◽  
Author(s):  
R. Binns ◽  
G. C. Clark ◽  
C. R. Simpson

Detailed information has been obtained on the normal lung mechanics, lung ventilation and blood gases and pH in unanaesthetized, restrained male and female rhesus monkeys. This information is compared with the limited amount of data previously available on lung function in the rhesus monkey, and with the pulmonary characteristics of the baboon and cynomolgus monkey.


2000 ◽  
Vol 17 (Supplement 19) ◽  
pp. 67
Author(s):  
D. H. Beck ◽  
U. Doepfmer ◽  
C. Sinemus ◽  
A. Bloch ◽  
W. J. Kox

Sign in / Sign up

Export Citation Format

Share Document