scholarly journals The Risk Factors for Development of Sepsis in Newborns with a Central Venous Catheter and their Association with the Serum Zinc Levels

Author(s):  
Lakshmi Jagath Kumar ◽  
Soundarya Mahalingam ◽  
Rukmini Mysore Srikantiah ◽  
Ali Kumble ◽  
Basavaprabhu Achappa
2021 ◽  
pp. 0310057X2110242
Author(s):  
Adrian D Haimovich ◽  
Ruoyi Jiang ◽  
Richard A Taylor ◽  
Justin B Belsky

Vasopressors are ubiquitous in intensive care units. While central venous catheters are the preferred route of infusion, recent evidence suggests peripheral administration may be safe for short, single-agent courses. Here, we identify risk factors and develop a predictive model for patient central venous catheter requirement using the Medical Information Mart for Intensive Care, a single-centre dataset of patients admitted to an intensive care unit between 2008 and 2019. Using prior literature, a composite endpoint of prolonged single-agent courses (>24 hours) or multi-agent courses of any duration was used to identify likely central venous catheter requirement. From a cohort of 69,619 intensive care unit stays, there were 17,053 vasopressor courses involving one or more vasopressors that met study inclusion criteria. In total, 3807 (22.3%) vasopressor courses involved a single vasopressor for less than six hours, 7952 (46.6%) courses for less than 24 hours and 5757 (33.8%) involved multiple vasopressors of any duration. Of these, 3047 (80.0%) less than six-hour and 6423 (80.8%) less than 24-hour single vasopressor courses used a central venous catheter. Logistic regression models identified associations between the composite endpoint and intubation (odds ratio (OR) 2.36, 95% confidence intervals (CI) 2.16 to 2.58), cardiac diagnosis (OR 0.72, CI 0.65 to 0.80), renal impairment (OR 1.61, CI 1.50 to 1.74), older age (OR 1.002, Cl 1.000 to 1.005) and vital signs in the hour before initiation (heart rate, OR 1.006, CI 1.003 to 1.009; oxygen saturation, OR 0.996, CI 0.993 to 0.999). A logistic regression model predicting the composite endpoint had an area under the receiver operating characteristic curve (standard deviation) of 0.747 (0.013) and an accuracy of 0.691 (0.012). This retrospective study reveals a high prevalence of short vasopressor courses in intensive care unit settings, a majority of which were administered using central venous catheters. We identify several important risk factors that may help guide clinicians deciding between peripheral and central venous catheter administration, and present a predictive model that may inform future prospective trials.


2015 ◽  
Vol 4 (2) ◽  
Author(s):  
Savino Occhionorelli ◽  
Sergio Gianesini ◽  
Lorenzo Marinelli ◽  
Marianna Daniele ◽  
Sara Chierici ◽  
...  

Venous malformations are rare but possible findings too, constituting a further risk factor for central venous catheter procedures. Herein we describe a case of death because of an innominate vein perforation by a catheter that incidentally was tucked into a sacciform malformation. Even if the technology advancement is constantly offering us new investigation tools, up to now diagnostic options are limited in the detection of those malformations that could potentially lead to dramatic complications as the described one. The present work raises the awareness about rare venous anomalies and their potential clinical implications. A proper literature review and diagnostic implementation proposal are reported.


Perinatology ◽  
2019 ◽  
Vol 30 (2) ◽  
pp. 60 ◽  
Author(s):  
Young Duck Kim ◽  
Na Mi Lee ◽  
Su Yeong Kim ◽  
Dae Yong Yi ◽  
Sin Weon Yun ◽  
...  

1991 ◽  
Vol 15 (5) ◽  
pp. 513-516 ◽  
Author(s):  
Leslie Mukau ◽  
Mark A. Talamini ◽  
James V. Sitzmann

2004 ◽  
Vol 18 (3) ◽  
pp. 304-308 ◽  
Author(s):  
Mandakini Pawar ◽  
Yatin Mehta ◽  
Pawan Kapoor ◽  
Jitendra Sharma ◽  
Abhinav Gupta ◽  
...  

2013 ◽  
Vol 34 (9) ◽  
pp. 980-983 ◽  
Author(s):  
Paul Chittick ◽  
Sobia Azhar ◽  
Kalyani Movva ◽  
Paula Keller ◽  
Judith A. Boura ◽  
...  

The risks and microbiology for peripherally inserted central catheters (PICCs) are less well described than those for traditional central catheters, particularly as they pertain to duration of catheterization. We compared patients with early- and late-onset PICC bloodstream infections at our institution and found significant differences in microbiologic etiologies.


Sign in / Sign up

Export Citation Format

Share Document