Inter-rater Reliability of Sonographic Optic Nerve Sheath Diameter Measurements by Emergency Medicine Physicians

2017 ◽  
Vol 36 (8) ◽  
pp. 1579-1584 ◽  
Author(s):  
Stephanie Oberfoell ◽  
David Murphy ◽  
Andrew French ◽  
Stacy Trent ◽  
David Richards
2022 ◽  
Vol 14 (1) ◽  
Author(s):  
Jason B. Jennings ◽  
Cynthia Oliva ◽  
Michael Joyce ◽  
Michael J. Vitto ◽  
Jordan Tozer ◽  
...  

Abstract Objectives Ultrasound measurement of the optic nerve sheath diameter (ONSD) is a rapid, non-invasive means to indirectly assess intracranial pressure. Previous research has demonstrated the ability of emergency physicians to measure ONSD accurately with bedside ultrasound when compared to CT scan or MRI, however the reliability of this measurement between two or more operators has been called into question (Hassen et al. in J Emerg Med 48:450–457, 2015; Shirodkar et al. in Ind J Crit Care Med 19:466–470, 2015). Given the need for accurate and precise measurement to use this as a screening exam, we sought to determine the inter-rater reliability between ONSD measurements obtained in real time by fellowship-trained emergency ultrasound physicians. Methods Three ultrasound fellowship-trained emergency physicians measured bilateral ONSD of 10 healthy volunteers using a high-frequency linear transducer. The physicians were blinded to the other scanners’ measurements, and no instructions were given other than to obtain the ONSD. Each sonographer measured the ONSD in real time and it was recorded by a research coordinator. All measurements were recorded in millimeters. Intraclass correlation coefficients (ICCs) were calculated to estimate the inter-rater reliability. Results A total of 60 measurements of ONSD were obtained. The average measurement was 4.3 mm (3.83–4.77). Very little variation was found between the three physicians, with a calculated ICC of 0.82 (95% confidence interval 0.63–0.92). Conclusions ONSD measurement obtained by ultrasound fellowship-trained emergency medicine physicians is a reliable measurement with a high degree of correlation between scanners.


2020 ◽  
pp. bjophthalmol-2020-317717
Author(s):  
Tou-Yuan Tsai ◽  
George Gozari ◽  
Yung-Cheng Su ◽  
Yi-Kung Lee ◽  
Yu-Kang Tu

Background/aimsTo assess changes in optic nerve sheath diameter (ONSD) at high altitude and in acute mountain sickness (AMS).MethodsCochrane Library, EMBASE, Google Scholar and PubMed were searched for articles published from their inception to 31st of July 2020. Outcome measures were mean changes of ONSD at high altitude and difference in ONSD change between subjects with and without AMS. Meta-regressions were conducted to investigate the relation of ONSD change to altitude and time spent at that altitude.ResultsEight studies with 248 participants comparing ONSD from sea level to high altitude, and five studies with 454 participants comparing subjects with or without AMS, were included. ONSD increased by 0.14 mm per 1000 m after adjustment for time (95% CI: 0.10 to 0.18; p<0.01). Restricted cubic spline regression revealed an almost linear relation between ONSD change and time within 2 days. ONSD was greater in subjects with AMS (mean difference=0.47; 95% CI: 0.14 to 0.80; p=0.01; I2=89.4%).ConclusionOur analysis shows that ONSD changes correlate with altitude and tend to increase in subjects with AMS. Small study number and high heterogeneity are the limitations of our study. Further large prospective studies are required to verify our findings.


Sign in / Sign up

Export Citation Format

Share Document