scholarly journals FEM Analysis on Concrete Columns Confined with CFRP Sheets by ANSYS

2016 ◽  
Vol 4 (Special Issue) ◽  
pp. 196-199
Author(s):  
Kiran Malipatil ◽  
Tejas D. Doshi
2018 ◽  
Vol 162 ◽  
pp. 04005
Author(s):  
Kaiss Sarsam ◽  
Raid Khalel ◽  
Mohammed Hadi

An experimental study was carried out to investigate the behavior of normal strength reinforce concret (RC) circular short column strengthned with “carbon fiber reinforced polymer (CFRP) sheets”. Three series comprising totally of (15) specimens loaded until failure under concentric compresion load. Strengthening was varied by changing the number of CFRP strips, spacing and wrapping methods. The findings of this research can be summarized as follows: for the columns without CFRP, the influence of the tie spacing was significant: compared with 130 mm tie spacing, dropping the spacing to 100 mm and 70 mm increased the load carrying capacity by 18% and 26%, respectively. The columns with less internal confinement (lesser amount of ties) were strengthened more significantly by the CFRP than the ones with greater amount of internal ties. As an example of the varying effectiveness of the fully wrapped CFRP, the column with ties at 130 mm was strengthened by 90% with the CFRP. In contrast, the ones with 70 mm spaced ties only increased in strength with CFRP by 66%. Compared with the control specimen (no CFRP), the same amount of CFRP when used as hoop strips led to more strengthening than using CFRP as a spiral strip- the former led to nearly 9% more strengthening than the latter in the case of 130 mm spaced internal steel ties. In the case of 100 mm internal steel ties, the difference (between the hoops & spiral CFRP strengthening) is close to 4%. In contrast, there is no difference between the two methods of strengthening in the heavily tied columns (70 mm tied spacing).


2008 ◽  
Vol 44 (3) ◽  
pp. 199-208 ◽  
Author(s):  
V. Tamuzs ◽  
V. Valdmanis ◽  
R. Tepfers ◽  
K. Gylltoft

2008 ◽  
Vol 47-50 ◽  
pp. 1282-1285 ◽  
Author(s):  
Hua Wei ◽  
Ji Sheng Li ◽  
Xia Guo

Fiber reinforced polymer (FRP) composites are becoming more frequently used in civil engineering structures because of their superiors advantages. While in practice, partial deterioration of concrete columns occurs occasionally, frost damage, aging or construction quality might lead to concrete deterioration. However, confined the whole columns including intact and deteriorated parts has been regarded as a waste. Few literatures have involved in partial confinement only to defect parts. The objective of this paper is to present an effective method to deal with the partial deteriorated strength columns, and to gain insight into the mechanical behavior of the defect part. Five groups of plain square columns are cast, different layers of CFRP sheets have been wrapped just on the deteriorated part to investigate the improvement with CFRP sheets and to verify the practicability of partial confinement. Columns are subjected to monotonic axial compression until failure occurs. Axial load, axial and transverse strains are measured to compare the different behaviors and to evaluate confinement level supplied by CFRP sheets. Experimental results show that partial confinement with CFRP can significantly enhance the strength and the ductility of the deteriorated strength part, then, the load capacity of the entire column can be improved subsequently.


2002 ◽  
Vol 35 (1) ◽  
pp. 50-58 ◽  
Author(s):  
I. A. E. M. Shehata ◽  
L. A. V. Carneiro ◽  
L. C. D. Shehata
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document