acoustic doppler profiler
Recently Published Documents


TOTAL DOCUMENTS

37
(FIVE YEARS 6)

H-INDEX

10
(FIVE YEARS 0)

Data ◽  
2020 ◽  
Vol 5 (3) ◽  
pp. 61
Author(s):  
Marilou Jourdain de Thieulloy ◽  
Mairi Dorward ◽  
Chris Old ◽  
Roman Gabl ◽  
Thomas Davey ◽  
...  

Acoustic Doppler Profilers (ADPs) are routinely used to measure flow velocity in the ocean, enabling multi-points measurement along a profile while Acoustic Doppler Velocimeters (ADVs) are laboratory instruments that provide very precise point velocity measurement. The experimental set-up allows laboratory comparison of measurement from these two instruments. Simultaneous multi-point measurements of velocity along the horizontal tank profile from Single-Beam Acoustic Doppler Profiler (SB-ADP) were compared against multiple co-located point measurements from an ADV. Measurements were performed in the FloWave Ocean Energy Research Facility at the University of Edinburgh at flow velocities between 0.6 ms − 1 and 1.2 ms − 1 . This paper describes the data; the analysis of the inter-instrument comparison is presented in an associated Sensors paper by the same authors. This data-set contains (a) time series of raw SB-ADP uni-directional velocity measurements along a 10 m tank profile binned into 54 measurements cells and (b) ADV point measurements of three-directional velocity time series recorded in beam coordinates at selected locations along the profile. Associated with the data are instrument generated quality data, metadata and user-derived quality flags. An analysis of the quality of SB-ADP data along the profile is presented. This data-set provides multiple contemporaneous velocity measurements along the tank profile, relevant for correlation statistics, length-scale calculations and validation of numerical models simulating flow hydrodynamics in circular test facilities.


2020 ◽  
Vol 8 (6) ◽  
pp. 390
Author(s):  
Udara Rathnayake ◽  
Matt Folley ◽  
S.D.G.S.P. Gunawardane ◽  
Carwyn Frost

Representing the velocity at a tidal energy extraction site in a standardized manner is essential for the development of the tidal energy sector. The International Electrotechnical Commission (IEC) have issued a technical specification to determine the mean representative current velocity (MRV) relative to a tidal energy converter (TEC). This method determines the MRV using an acoustic Doppler profiler (ADP). This is used to evaluate the power performance of a TEC and so can have a significant influence on the power performance uncertainties, due to the cubed relationship of the MRV and power. This paper investigates these uncertainties in the MRV by considering four sources of uncertainty in the ADP. These are turbulence intensity, tilt, Doppler noise and beam misalignment of an ADP. A synthetically generated dataset is used to define current velocity and profile using the characteristics of currents and ADP. The generated synthetic dataset is processed to calculate the MRV based on the standard IEC method. An alternative method to calculate the MRV, called the temporal-spatial method (TSM), is proposed and the two methodologies are used to assess the error of the MRV. A sensitivity analysis shows that the errors of the MRV based on the standard IEC method are always higher than the TSM. The biases in the MRV based on the different combinations of the uncertainty are investigated and it is found that the bias for the MRVs based on the TSM method is generally less than that of the IEC method.


Sign in / Sign up

Export Citation Format

Share Document