Multi-contrast CT imaging using a high energy resolution CdTe detector and a CZT photon-counting detector

2022 ◽  
Vol 17 (01) ◽  
pp. P01004
Author(s):  
N. Clements ◽  
D. Richtsmeier ◽  
A. Hart ◽  
M. Bazalova-Carter

Abstract Computed tomography (CT) imaging with high energy resolution detectors shows great promise in material decomposition and multi-contrast imaging. Multi-contrast imaging was studied by imaging a phantom with iodine (I), gadolinium (Gd), and gold (Au) solutions, and mixtures of the three using a cadmium telluride (CdTe) spectrometer with an energy resolution of 1% as well as with a cadmium zinc telluride (CZT) detector with an energy resolution of 13%. The phantom was imaged at 120 kVp and 1.1 mA with 7 mm of aluminum filtration. For the CdTe data collection, the phantom was imaged using a 0.2 mm diameter x-ray beam with 96 ten-second data acquisitions across the phantom at 45 rotation angles. For the CZT detector, we had 720 projections using a cone beam, and the six detector energy thresholds were set to 23, 33, 50, 64, 81, and 120 keV so that three thresholds corresponded to the K-edges of the contrast agents. Contrast agent isolation methods were then examined. K-edge subtraction and novel spectrometric algebraic image reconstruction (SAIR) were used for the CdTe data. K-edge subtraction alone was used for the CZT data. Linearity plots produced similar R 2 values and slopes for all three reconstruction methods. Comparing CdTe methods, SAIR offered less noise than CdTe K-edge subtraction and better geometric accuracy at low contrast concentrations. CdTe contrast agent images of I, Gd, and Au offered less noise and greater contrast than the CZT images, highlighting the benefits of high energy resolution CdTe detectors for possible use in pre-clinical or clinical CT imaging.

1995 ◽  
Vol 66 (2) ◽  
pp. 2072-2074 ◽  
Author(s):  
M. Bissen ◽  
M. Fisher ◽  
G. Rogers ◽  
D. Eisert ◽  
K. Kleman ◽  
...  

2017 ◽  
Vol 139 (49) ◽  
pp. 18024-18033 ◽  
Author(s):  
Rebeca G. Castillo ◽  
Rahul Banerjee ◽  
Caleb J. Allpress ◽  
Gregory T. Rohde ◽  
Eckhard Bill ◽  
...  

2007 ◽  
Vol 127 (16) ◽  
pp. 164702 ◽  
Author(s):  
Alessandro Baraldi ◽  
Erik Vesselli ◽  
Laura Bianchettin ◽  
Giovanni Comelli ◽  
Silvano Lizzit ◽  
...  

2015 ◽  
Vol 112 (52) ◽  
pp. 15803-15808 ◽  
Author(s):  
Ofer Hirsch ◽  
Kristina O. Kvashnina ◽  
Li Luo ◽  
Martin J. Süess ◽  
Pieter Glatzel ◽  
...  

The lanthanum-based materials, due to their layered structure and f-electron configuration, are relevant for electrochemical application. Particularly, La2O2CO3 shows a prominent chemoresistive response to CO2. However, surprisingly less is known about its atomic and electronic structure and electrochemically significant sites and therefore, its structure–functions relationships have yet to be established. Here we determine the position of the different constituents within the unit cell of monoclinic La2O2CO3 and use this information to interpret in situ high-energy resolution fluorescence-detected (HERFD) X-ray absorption near-edge structure (XANES) and valence-to-core X-ray emission spectroscopy (vtc XES). Compared with La(OH)3 or previously known hexagonal La2O2CO3 structures, La in the monoclinic unit cell has a much lower number of neighboring oxygen atoms, which is manifested in the whiteline broadening in XANES spectra. Such a superior sensitivity to subtle changes is given by HERFD method, which is essential for in situ studying of the interaction with CO2. Here, we study La2O2CO3-based sensors in real operando conditions at 250 °C in the presence of oxygen and water vapors. We identify that the distribution of unoccupied La d-states and occupied O p- and La d-states changes during CO2 chemoresistive sensing of La2O2CO3. The correlation between these spectroscopic findings with electrical resistance measurements leads to a more comprehensive understanding of the selective adsorption at La site and may enable the design of new materials for CO2 electrochemical applications.


2018 ◽  
Vol 89 (11) ◽  
pp. 113306 ◽  
Author(s):  
Glyn A. Collinson ◽  
Dennis J. Chornay ◽  
Alex Glocer ◽  
Nick Paschalidis ◽  
Eftyhia Zesta

2018 ◽  
Vol 25 (4) ◽  
pp. 997-1009 ◽  
Author(s):  
Alain Manceau ◽  
Paco Bustamante ◽  
Ahmed Haouz ◽  
Jean Paul Bourdineaud ◽  
Maria Gonzalez-Rey ◽  
...  

1991 ◽  
Vol 24 (6) ◽  
pp. 1042-1050 ◽  
Author(s):  
E. Burkel ◽  
B. Dorner ◽  
Th. Illini ◽  
J. Peisl

Very high-energy resolution measurements using X-rays can be achieved by extreme backreflection (Bragg angle close to 90°) from perfect crystals. This technique, combined with the high intensity of X-rays emitted by synchrotron-radiation sources, allowed the development of the instrument INELAX for inelastic scattering experiments. The principles and test results are discussed.


Sign in / Sign up

Export Citation Format

Share Document