ratiometric sensor
Recently Published Documents


TOTAL DOCUMENTS

79
(FIVE YEARS 3)

H-INDEX

22
(FIVE YEARS 0)



Author(s):  
Chen Lin ◽  
Man Wang ◽  
Jiawei Tang ◽  
Zhenyan Zhu ◽  
Pengyan Wu ◽  
...  


2021 ◽  
pp. 338992
Author(s):  
Xuan Chen ◽  
Yangguang Li ◽  
Xiang Li ◽  
Renjie Li ◽  
Bangce Ye


Author(s):  
Niyati H. Mudliar ◽  
Prabhakar M. Dongre ◽  
Prabhat K. Singh
Keyword(s):  


2020 ◽  
Vol 181 ◽  
pp. 108528 ◽  
Author(s):  
Niyati H. Mudliar ◽  
Prabhakar M. Dongre ◽  
Prabhat K. Singh


2020 ◽  
Vol 11 (17) ◽  
pp. 2666-2678
Author(s):  
Saranya Radhakrishnan ◽  
Jacob Norley ◽  
Stefan Wendt ◽  
Nathan LeRoy ◽  
Hana Hall ◽  
...  


2020 ◽  
Vol 1127 ◽  
pp. 29-38
Author(s):  
Xiaojun He ◽  
Feng Ding ◽  
Wei Xu ◽  
Chuchu Xu ◽  
Yahui Li ◽  
...  


Small ◽  
2020 ◽  
Vol 16 (17) ◽  
pp. 1907522 ◽  
Author(s):  
Thuy T. Nguyen ◽  
Margaret Chern ◽  
R C. Baer ◽  
James Galagan ◽  
Allison M. Dennis


Sensors ◽  
2020 ◽  
Vol 20 (5) ◽  
pp. 1524
Author(s):  
Min Zhang ◽  
Zeyuan Zhang ◽  
Yanjing Yang ◽  
Yi Zhang ◽  
Yufei Wang ◽  
...  

Accurate analysis of pesticide residue in real samples is essential for food safety and environmental protection. However, a traditional electrochemical sensor based on single-signal output is easily affected by background noise, environmental conditions, electrode diversity, and a complex matrix of samples, leading to extremely low accuracy. Hence, in this paper, a ratiometric strategy based on dual-signal output was adopted to build inner correction for sensing of widely-used carbaryl (CBL) for the first time. By comparison, Nile blue A (NB) was selected as reference probe, due to its well-defined peak, few effects on the target peak of CBL, and excellent stability. The effects of a derivatization method, technique mode, and pH were also investigated. Then the performance of the proposed ratiometric sensor was assessed in terms of three aspects including the elimination of system noise, electrode deviation and matrix effect. Compared with traditional single-signal sensor, the ratiometric sensor showed a much better linear correlation coefficient (r > 0.99), reproducibility (RSD < 10%), and limit of detection (LOD = 1.0 μM). The results indicated the introduction of proper reference probe could ensure the interdependence of target and reference signal on the same sensing environment, thus inner correction was fulfilled, which provided a promising tool for accurate analysis.



Sign in / Sign up

Export Citation Format

Share Document