tubular sections
Recently Published Documents


TOTAL DOCUMENTS

107
(FIVE YEARS 29)

H-INDEX

16
(FIVE YEARS 5)

2021 ◽  
Author(s):  
Sachin Bhardwaj ◽  
R.M. Chandima Ratnayake

Abstract Maintaining minimum allowable distance between proximity welds has always been considered a subject of debate between design engineers, welding engineers/inspectors and fabricators/engineering contractors. The scattered nature of guidelines available in welding codes and standards for maintain minimum allowable distance pose a significant challenge in the welding procedure and inspection criteria development process. This is especially critical for complex welded joints on submerged sections of offshore structures, in compact layouts/branched connections of topside piping components, and on topside structural joints (depending on the complexity). This manuscript presents the findings of an experimental study that was performed by fabricating two girth welds at a proximity on an S355 steel tubular section having diameter of 219.1 mm and thickness of 8.18 mm. Proximity girth welds were fabricated on S355 tubular sections at three different distances between their weld toe as 5, 10 & 15mm respectively using two different welding procedures. Welding procedure qualification record (WPQR) was performed, and all prescribed mechanical tests were recorded as per NORSOK M-101, a structural steel fabrication code. Although all results from mechanical test met minimum specified values as defined in the NORSOK code, research findings revealed noticeable difference in Charpy and hardness values for proximity region between adjacent welds. Considerable changes in final microstructure morphology were observed between proximity welds due to successive thermal cycles. These observations can form basis for future welding procedure qualification of critical welded joints, especially for proximity welds on critical welded joints of offshore structures and welds fabricated during replacement/repair procedures in compact piping layouts.


Abstract. This paper presents an experimental investigation on the behaviour of concrete filled steel tube columns under axial compression. The steel columns were filled with self-compacting and self-curing concrete instead of normal conventional concrete. A test program consisting of square column, circular column and rectangular column was firstly conducted. The behaviour of three concrete filled steel tubular sections (CFSTs) under axial load is presented. The effect of steel tube dimensions, shapes and confinement of concrete are also examined. Measured column strengths are compared with the values predicted by Euro code 4 and American codes. Euro code 4, gives good estimation of self-compaction concrete. However, lower values as measured during the experiments were predicted by the American Concrete Institute (ACI) equation. Also, the effect of thickness of steel tubes, concrete cube strength and steel percentage is also studied. In addition to CFST column the steel tube also acts as confinement for concrete.


Sign in / Sign up

Export Citation Format

Share Document