prostate motion
Recently Published Documents


TOTAL DOCUMENTS

268
(FIVE YEARS 21)

H-INDEX

25
(FIVE YEARS 1)

BJR|Open ◽  
2021 ◽  
Author(s):  
Kentaro Nishioka ◽  
Kento Gotoh ◽  
Takayuki Hashimoto ◽  
Takashige Abe ◽  
Takahiro Osawa ◽  
...  

Objectives: The purpose of this study is to investigate whether verbal instructions are sufficient for bladder volume (BV) control not to deteriorate prostate position reproducibility in image-guided spot scanning proton therapy (SSPT) for localized prostate cancer. Methods: A total of 268 treatment sessions in 12 consecutive prostate cancer patients who were treated with image-guided SSPT with fiducial markers were retrospectively analyzed. In addition to strict rectal volume control procedures, simple verbal instructions to void urine one hour before the treatment were used here. The BV was measured by a Bladder Scan just before the treatment and the prostate motion was measured by intraprostatic fiducial markers and two sets of X-ray fluoroscopy images. The correlation between the BV change and prostate motion was assessed by linear mixed-effects models and systematic and random errors according to the reproducibility of the BV. Results: The mean absolute BV change during treatment was from −98.7 to 86.3 ml (median 7.1 ml). The mean absolute prostate motion of the patients in the left-right direction was −1.46 to 1.85 mm, in the cranial-caudal direction it was −6.10 to 3.65 mm, and in the anteroposterior direction −1.90 to 5.23 mm. There was no significant relationship between the BV change and prostate motion during SSPT. The early and late genitourinary and gastrointestinal toxicity was minimal with a minimum follow-up of 4.57 years. Conclusions: Simple verbal instructions about urination was suggested to be sufficient to control the BV not to impact on the prostate motion and clinical outcomes in image-guided SSPT. Careful attention to BV change is still needed when the seminal vesicle is to be treated. Advances in knowledge: Our data demonstrated that there was no apparent relationship between BV changes and prostate position reproducibility and simple verbal instruction about urination could be sufficient for image-guided SSPT.


2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Raffaella Lucchini ◽  
Denis Panizza ◽  
Riccardo Ray Colciago ◽  
Veronica Vernier ◽  
Martina Camilla Daniotti ◽  
...  

Abstract Purpose/objectives To report preliminary data on treatment outcome and compliance to dose-intensified organ sparing SBRT for prostate cancer using a novel electromagnetic transmitter-based tracking system (RayPilot® System) to account for intra-fractional organ motion. Material/methods Thirteen patients with intermediate unfavorable (9) and selected high-risk (4) prostate cancer underwent dose-escalated SBRT in 4 or 5 fractions (BED1.5 = 279 Gy and 253 Gy, respectively). The VMAT treatment consisted in two 6FFF or 10FFF full arcs optimized to have the 95% isodose covering at least 95% of the PTV (2 mm isotropic expansion of the CTV). Whenever the real-time tracking registered a displacement that exceeded 2 mm during the setup and/or the beam delivery, the treatment was interrupted and the prostate motion was promptly corrected. The incidence of treatment-related genitourinary (GU) and gastrointestinal (GI) toxicity, patient QoL and PSA outcomes were computed from the start of treatment to the last follow-up date. Results All patients completed the treatment in the expected time (10.2 +/− 4.2 minutes) and their compliance to the procedure was excellent. No clinically significant acute Grade 2 or higher GI (rectal) and GU side effects were observed within 90 days from the treatment completion. The median IPSS increased from 8 at baseline to 12 one-month after treatment and settled to 6 at 3 months. EPIC-26 scores in the urinary domain decreased from a median baseline of 86 pre-treatment to 79 at one-month and returned to baseline at a later timepoint (median score of 85 at 3 months). EPIC-26 scores in the bowel domains did not show significant changes within 3 months following RT. The prostate was found within 1 mm from its initial position in 78% of the beam-on time, between 1 and 2 mm in 20%, and exceeded 2 mm only in 2%, after correction for motion which was performed in 45% of the fractions, either during setup or beam delivery. Conclusions Our preliminary findings show that dose intensified SBRT for unfavorable prostate tumors does not come at the cost of an increased toxicity, provided that a reliable technique for real time prostate monitoring is ensured. Fast FFF beams contributed to reduce intra-fractional motion. These observations need to be confirmed on a larger scale and a longer follow up.


2021 ◽  
Vol 161 ◽  
pp. S690-S691
Author(s):  
D. Panizza ◽  
S. Trivellato ◽  
G. Montanari ◽  
V. Pisoni ◽  
V. Faccenda ◽  
...  
Keyword(s):  

2021 ◽  
Vol 161 ◽  
pp. S1140-S1141
Author(s):  
A. TAILLEZ ◽  
A.M. Bimbai ◽  
T. Lacornerie ◽  
M. Le Deley ◽  
E.F. Lartigau ◽  
...  

2021 ◽  
Vol 11 ◽  
Author(s):  
Alexandre Taillez ◽  
Andre-Michel Bimbai ◽  
Thomas Lacornerie ◽  
Marie-Cecile Le Deley ◽  
Eric F. Lartigau ◽  
...  

BackgroundUnderstanding intra-fractional prostate motions is crucial for stereotactic body radiation therapy (SBRT). No studies have focused on the intra-fractional prostate motions during re-irradiation with SBRT. The objective was to evaluate these translational and rotational motions in primary treated patients and in the context of re-irradiation.MethodsFrom January 2011 to March 2020, 162 patients with histologically proven prostate cancer underwent prostate SBRT, including 58 as part of a re-irradiation treatment. We used the continuous coordinates of the fiducial markers collected by an orthogonal X-ray dual-image monitoring system. The translations and rotations of the prostate were calculated. Prostate deviations representing overall movement was defined as the length of the 3D-vectors.ResultsA total of 858 data files were analyzed. The deviations over time in the group of primary treated patients were significantly larger than that of the group of re-irradiation, leading to a mean deviation of 2.73 mm (SD =1.00) versus 1.90 mm (SD =0.79), P<0.001. In the re-irradiation group, we identified displacements of -0.05 mm (SD =1.53), 0.20 mm (SD =1.46); and 0.42 mm (SD =1.24) in the left-right, superior-inferior and anterior-posterior planes. Overall, we observed increasing deviations over the first 30 min followed by a stabilization related to movements in the three translational axes.ConclusionThis is the first study to focus on intrafraction prostate motions in the context of re-irradiation. We observed that intra-fraction prostate motions persisted in the setting of re-irradiation, although they showed a significant reduction when compared with the first irradiation. These results will help to better estimate random errors during SBRT treatment of intra-prostatic recurrence after irradiation.


2021 ◽  
Author(s):  
Subaru Sawayanagi ◽  
Hideomi Yamashita ◽  
Mami Ogita ◽  
Yuki Nozawa ◽  
Yuichi Watanabe ◽  
...  

Abstract BackgroundThe aim of this study was to clarify the association between intrafractional prostate shift and hydrogel spacer.MethodsThirty-eight patients who received definitive volumetric modulated arc therapy (VMAT)-stereotactic body radiation therapy (SBRT) for prostate cancer with prostate motion monitoring in our institution in 2018–2019 were retrospectively evaluated. In order to move the rectum away from the prostate, hydrogel spacer (SpaceOAR system, Boston Scientific, Marlborough, the United States) injection was proposed to the patients as an option in case of meeting the indication of use. We monitored intrafractional prostate motion by using a 4-dimensional (4D) transperineal ultrasound (US) device: the Clarity 4D ultrasound system (Elekta AB). The deviation of the prostate was monitored in each direction: superior-inferior (SI), left-right (LR), and anterior-posterior (AP). We also calculated the vector length (VL). The maximum intrafractional displacement (MID) per fraction for each direction was detected and mean of MIDs was calculated per patient. The MIDs in the non-spacer group and the spacer group were compared using the unpaired t-test.ResultsWe reviewed 33 fractions in eight patients as the spacer group and 148 fractions in 30 patients as the non-spacer group. The superior MID was 0.47 ± 0.07 (mean ± SE) mm vs. 0.97 ± 0.24 mm (P = 0.014), the inferior MID was 1.07 ± 0.11 mm vs. 1.03 ± 0.25 mm (P = 0.88), the left MID was 0.74 ± 0.08 mm vs. 0.87 ± 0.27 mm (P = 0.55), the right MID was 0.67 ± 0.08 mm vs. 0.92 ± 0.21 mm (P = 0.17), the anterior MID was 0.45 ± 0.06 mm vs. 1.16 ± 0.35 mm (P = 0.0023), and the posterior MID was 1.57 ± 0.17 mm vs. 1.37 ± 0.22 mm (P = 0.56) in the non-spacer group and the spacer group, respectively. The max of VL was 2.24 ± 0.19 mm vs. 2.89 ± 0.62 mm (P = 0.19), respectively.ConclusionsOur findings suggest that intrafractional prostate motion during VMAT-SBRT was larger in patients with hydrogel spacer injection in the superior and anterior directions.


Author(s):  
Hiroki Sato ◽  
Takahiro Kato ◽  
Tomoaki Motoyanagi ◽  
Kimihiro Takemasa ◽  
Yuki Narita ◽  
...  

Abstract In recent years, a novel technique has been employed to maintain a distance between the prostate and the rectum by transperineally injecting a hydrogel spacer (HS). However, the effect of HS on the prostate positional displacement is poorly understood, despite its stability with HS in place. In this study, we investigated the effect of HS insertion on the interfraction prostate motion during the course of proton therapy (PT) for Japanese prostate cancer patients. The study population consisted of 22 cases of intermediate-risk prostate cancer with 11 cases with HS insertion and 11 cases without HS insertion. The irradiation position and preparation were similar for both groups. To test for reproducibility, regular confirmation computed tomography (RCCT) was done four times during the treatment period, and five times overall [including treatment planning CT (TPCT)] in each patient. Considering the prostate position of the TPCT as the reference, the change in the center of gravity of the prostate relative to the bony anatomy in the RCCTs of each patient was determined in the left–right (LR), superior–inferior (SI) and anterior–posterior (AP) directions. As a result, no significant difference was observed across the groups in the LR and SI directions. Conversely, a significant difference was observed in the AP direction (P < 0.05). The proportion of the 3D vector length ≤5 mm was 95% in the inserted group, but 55% in the non-inserted group. Therefore, HS is not only effective in reducing rectal dose, but may also contribute to the positional reproducibility of the prostate.


2020 ◽  
Vol 108 (3) ◽  
pp. e256-e257
Author(s):  
A. Cetnar ◽  
A.S. Ayan ◽  
G. Graeper ◽  
M. Weldon ◽  
K. Woods ◽  
...  