cyanoacrylate adhesive
Recently Published Documents


TOTAL DOCUMENTS

187
(FIVE YEARS 25)

H-INDEX

23
(FIVE YEARS 2)

2022 ◽  
Vol 3 (1) ◽  
pp. 64-77
Author(s):  
Anna Rudawska ◽  
Magd Abdel Wahab ◽  
Miroslav Müller ◽  
Dana Stančeková

This paper presents issues related to the determination of the selected mechanical properties of adhesive joints made of polymeric pipes and the evaluation of the leak-tightness of the adhesive joints. The article attempts to demonstrate that the type of adhesive may affect the quality of adhesive joints in terms of both tightness and strength of joints. Five types of the polymer pipes differing in a polypropylene and a polyvinyl chloride, diameter and a wall thickness were used in the experiments. Two types of the adhesives were used to make the adhesive joints: Loctite 3430 A&B Hysol, a two-component epoxy adhesive, and Loctite 406, a one-component cyanoacrylate adhesive. Based on the leak-tightness tests results, it was possible to determine the quality of their adhesive joints without damaging the samples, while their tensile strength was determined through the strength tests. The tests performed allowed for the conclusion that the use of the polyvinyl chloride pipes and Loctite 406 one-component adhesive is recommended for this type of adhesive joints.


Materials ◽  
2021 ◽  
Vol 14 (22) ◽  
pp. 6938
Author(s):  
Anna Rudawska ◽  
Izabela Miturska-Barańska ◽  
Elżbieta Doluk

The purpose of the paper is to determine the impact of surface treatment on the strength of adhesive joints, made from various steel sheets. Two variants of the surface treatment steel adherends were used: without the varnish coat and with the varnish coat, using three polymer-based varnishes (a simple, a hybrid, and a gel). Two types of the adhesives were used to prepare the adhesive joints: a single-component cyanoacrylate adhesive and a two-component epoxy adhesive. A strength test of the adhesive joints (EN DIN 1465 standard), a coating adhesion test (ASTM D3359-B standard), and surface topography, as well as surface roughness, parameters (PN-EN ISO 11562, PN-EN ISO 4287, and PN-EN ISO 25178 standards) were used. Based on the strength tests, it was observed that the adhesive joints, with the hybrid varnish onto the adherend’s surface, achieved markedly lower shear strength. The best results, in terms of the adhesive joint strength, made using the cyanoacrylate adhesive were achieved for the joints where the adherends were coated with a simple varnish, while in the joints made using the epoxy adhesive, the highest shear strength was achieved by the joints of sheets whose surfaces were coated with the gel varnish.


2021 ◽  
Vol 36 ◽  
pp. 132-138
Author(s):  
Ziyi Cao ◽  
Xiaodong Zhu ◽  
Dongxiao Xu ◽  
Pei Dong ◽  
Mason Oliver Lam Chee ◽  
...  

Surgery ◽  
2021 ◽  
Author(s):  
Bárbara Pérez-Köhler ◽  
Selma Benito-Martínez ◽  
Francisca García-Moreno ◽  
Marta Rodríguez ◽  
Gemma Pascual ◽  
...  

Flebologiia ◽  
2021 ◽  
Vol 15 (4) ◽  
pp. 297
Author(s):  
O. Shirinbek ◽  
S.N. Odinokova

2020 ◽  
pp. 1-16
Author(s):  
Philipp Moritz ◽  
Friedrich Bürger ◽  
Lienhard Wegewitz ◽  
Wolfgang Maus-Friedrichs

2020 ◽  
Vol 5 (4) ◽  
pp. 13-19
Author(s):  
S Sadatmansouri ◽  
SH Moradi ◽  
B iranpour ◽  
◽  
◽  
...  

2020 ◽  
Vol 11 (2) ◽  
pp. 391-394
Author(s):  
Aika Tsutsui ◽  
Kazunobu Sugihara ◽  
Masaki Tanito

A 5-year-old Japanese boy presented to the emergency room of our hospital because his right eye had been glued shut for 2 h following instillation of cyanoacrylate adhesive. The clinical examination showed redness of the right upper and lower lid skin; the right eyelid margins adhered to each other because of matting of the eyelashes, and crystallized glue was found within the matted eyelashes. The “hook” technique, which separates the eyelids using a blunt-tip device, was performed to separate the lids. The technique seems to be simple and safe for physicians such as ophthalmology residents to use to treat cyanoacrylate-induced adhesion of the eyelids of patients who often first present to their local emergency room as in our case.


Sign in / Sign up

Export Citation Format

Share Document