filter test
Recently Published Documents


TOTAL DOCUMENTS

155
(FIVE YEARS 27)

H-INDEX

9
(FIVE YEARS 2)

2021 ◽  
Vol 2 (1) ◽  
pp. 46-50
Author(s):  
Bagus Triatmojo

HIV cases in Jepara District in recent years have demanded the handling of several aspects simultaneously including the Blood Transfusion Unit (BTU). HIV can be transmitted through blood transfusion or other blood products. BTU of PMI Jepara Regency carries out recruitment of voluntary donor from Jepara society. The HIV examination as part of an IMLTD screening test is done for safety of donor blood. The HIV examination in all donor blood uses rapid and elisa method. Examination results are stated as reactive and non reactive. Research objective to find out the description of HIV examination results in donor blood at the BTU of PMI Kabupaten Jepara in 2019. Research method the research type was descriptive using records of donor data at BTU of PMI Kabupaten Jepara in 2019. The examination results of reactive HIV in 12 donor blood (0,08%). non-reactive blood donor of HIV  in age groups 18 years, 18-24, 25-44, 45-59, and ≥ 60 years respectively 9,55%, 22,39%, 51,75%, 16,01% and 0,21%. Reactive HIV in age groups 18-24, 25-44, and 45-59 years were 0,034%, 0,034%, and 0,13%. Non-reactive HIV in men 68,22% and in women 31,70%. Reactive HIV in men 0,07%, and women 0,01%. Non-reactive HIV in voluntary donor blood was 99,779% and substitute donor was 0,127%. HIV of reactive voluntary donor blood was 0,074%, and substitute donor was 0,007%. HIV filter test is indispensable for blood safety because the age, gender and blood type of donors have the potential for reactive HIV.


2021 ◽  
Author(s):  
Murray Moore ◽  
Kirk Reeves
Keyword(s):  

2021 ◽  
Vol 21 ◽  
pp. 210224
Author(s):  
Tobias Rüggeberg ◽  
Ana Milosevic ◽  
Patrick Specht ◽  
Andreas Mayer ◽  
Joachim Frey ◽  
...  

Parasitology ◽  
2020 ◽  
pp. 1-7
Author(s):  
Danielle de Freitas Bezerra ◽  
Marta Cristhiany Cunha Pinheiro ◽  
Luciene Barbosa ◽  
Agostinho Gonçalves Viana ◽  
Ricardo Toshio Fujiwara ◽  
...  

Abstract This study aimed to evaluate the performance of the point-of-care circulating cathodic antigen (POC-CCA) test in a highly endemic area in Brazil, comparing it to the Kato-Katz (KK) technique for sensitivity, specificity and the intensity of the reaction of the test in relation to the parasitic load. The community in Sergipe, Brazil, participated in the study, providing three stool samples, one of urine (POC-CCA) and fingers tick blood sample was tested by enzyme-linked immunosorbent assay (ELISA). Sensitivity, specificity, positive predictive value, negative predictive value, accuracy, kappa coefficient and Spearman's correlation were calculated for the POC-CCA test using the KK as the reference. The prevalence of schistosomiasis by KK testing was 48.82%; POC-CCA (t+) 66.14%; POC-CCA (t−) 45.24%. ELISA results showed 100% agreement in individuals with high and moderate eggs per gram (EPG). POC-CCA presented good diagnostic performance in individuals with medium and high EPG, but there were a high number of false negatives in individuals with low intensity infections. As observed, POC-CCA-filter test improves accuracy and sensitivity compared to a conventional test.


Sign in / Sign up

Export Citation Format

Share Document