target definition
Recently Published Documents


TOTAL DOCUMENTS

203
(FIVE YEARS 39)

H-INDEX

22
(FIVE YEARS 3)

2021 ◽  
Vol 11 ◽  
Author(s):  
Gustavo R. Sarria ◽  
Zuzanna Smalec ◽  
Thomas Muedder ◽  
Jasmin A. Holz ◽  
Davide Scafa ◽  
...  

PurposeTo simulate and analyze the dosimetric differences of intraoperative radiotherapy (IORT) or pre-operative single-fraction stereotactic radiosurgery (SRS) in addition to post-operative external beam radiotherapy (EBRT) in Glioblastoma (GB).MethodsImaging series of previously treated patients with adjuvant radiochemotherapy were analyzed. For SRS target definition, pre-operative MRIs were co-registered to planning CT scans and a pre-operative T1-weighted gross target volume (GTV) plus a 2-mm planning target volume (PTV) were created. For IORT, a modified (m)GTV was expanded from the pre-operative volume, in order to mimic a round cavity as during IORT. Dose prescription was 20 Gy, homogeneously planned for SRS and calculated at the surface for IORT, to cover 99% and 90% of the volumes, respectively. For tumors > 2cm in maximum diameter, a 15 Gy dose was prescribed. Plan assessment was performed after calculating the 2-Gy equivalent doses (EQD2) for both boost modalities and including them into the EBRT plan. Main points of interest encompass differences in target coverage, brain volume receiving 12 Gy or more (V12), and doses to various organs-at-risk (OARs).ResultsSeventeen pre-delivered treatment plans were included in the study. The mean GTV was 21.72 cm3 (SD ± 19.36) and mGTV 29.64 cm3 (SD ± 25.64). The mean EBRT and SRS PTV were 254.09 (SD ± 80.0) and 36.20 cm3 (SD ± 31.48), respectively. Eight SRS plans were calculated to 15 Gy according to larger tumor sizes, while all IORT plans to 20 Gy. The mean EBRT D95 was 97.13% (SD ± 3.48) the SRS D99 99.91% (SD ± 0.35) and IORT D90 83.59% (SD ± 3.55). Accounting for only-boost approaches, the brain V12 was 49.68 cm3 (SD ± 26.70) and 16.94 cm3 (SD ± 13.33) (p<0.001) for SRS and IORT, respectively. After adding EBRT results respectively to SRS and IORT doses, significant lower doses were found in the latter for mean Dmax of chiasma (p=0.01), left optic nerve (p=0.023), right (p=0.008) and left retina (p<0.001). No significant differences were obtained for brainstem and cochleae.ConclusionDose escalation for Glioblastoma using IORT results in lower OAR exposure as conventional SRS.


Author(s):  
Peter Ferjancic ◽  
Uulke A van der Heide ◽  
Cynthia Ménard ◽  
Robert Jeraj

2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Niccolò Giaj-Levra ◽  
Vanessa Figlia ◽  
Francesco Cuccia ◽  
Rosario Mazzola ◽  
Luca Nicosia ◽  
...  

Abstract Background Approximately one third of cancer patients will develop spinal metastases, that can be associated with back pain, neurological symptoms and deterioration in performance status. Stereotactic radiosurgery (SRS) and stereotactic body radiotherapy (SBRT) have been offered in clinical practice mainly for the management of oligometastatic and oligoprogressive patients, allowing the prescription of high total dose delivered in one or few sessions to small target volumes, minimizing the dose exposure of normal tissues. Due to the high delivered doses and the proximity of critical organs at risk (OAR) such as the spinal cord, the correct definition of the treatment volume becomes even more important in SBRT treatment, thus making it necessary to standardize the method of target definition and contouring, through the adoption of specific guidelines and specific automatic contouring tools. An automatic target contouring system for spine SBRT is useful to reduce inter-observer differences in target definition. In this study, an automatic contouring tool was evaluated. Methods Simulation CT scans and MRI data of 20 patients with spinal metastases were evaluated. To evaluate the advantage of the automatic target contouring tool (Elements SmartBrush Spine), which uses the identification of different densities within the target vertebra, we evaluated the agreement of the contours of 20 spinal target (2 cervical, 9 dorsal and 9 lumbar column), outlined by three independent observers using the automatic tool compared to the contours obtained manually, and measured by DICE similarity coefficient. Results The agreement of GTV contours outlined by independent operators was superior with the use of the automatic contour tool compared to manually outlined contours (mean DICE coefficient 0.75 vs 0.57, p = 0.048). Conclusions The dedicated contouring tool allows greater precision and reduction of inter-observer differences in the delineation of the target in SBRT spines. Thus, the evaluated system could be useful in the setting of spinal SBRT to reduce uncertainties of contouring increasing the level of precision on target delivered doses.


2021 ◽  
Vol 161 ◽  
pp. S1520-S1522
Author(s):  
W. Häger ◽  
M. Lazzeroni ◽  
M. Astaraki ◽  
I. Toma-Dasu

2021 ◽  
Vol 161 ◽  
pp. S731-S733
Author(s):  
B. Eiben ◽  
E. Chandy ◽  
A. Abravan ◽  
V. Rompokos ◽  
H. Grimes ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document