array coils
Recently Published Documents


TOTAL DOCUMENTS

98
(FIVE YEARS 15)

H-INDEX

23
(FIVE YEARS 1)

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Po-Wei Cheng ◽  
Tzi-Dar Chiueh ◽  
Jyh-Horng Chen

AbstractLatest simultaneous multi-slice (SMS) methods greatly benefit MR efficiency for recent studies using parallel imaging technique. However, these methods are limited by the requirement of array coils. The proposed Coherent Wideband method, which employs an extended field of view to separate multiple excited slices, can be applied to any existing MRI instrument, even those without array coils. In this study, the Coherent Wideband echo-planar imaging method was implemented on 7 T animal MRI to exhibit comprehensive enhancements in neuro-architecture, including diffusion tensor imaging (DTI) and functional MR studies (fMRI). Under the same scan time, the time-saving effect can be manipulated to increase the number of averages for DTI SNR improvement, reducing fractional anisotropy difference by 56.9% (from 0.072 to 0.041) and the deviation angle by 64% (from 25.3° to 16.2°). In summary, Coherent Wideband Echo Planar Imaging (EPI) will provide faster, higher resolution, thinner slice, or higher SNR imaging for precision neuro-architecture studies.


2021 ◽  
Author(s):  
Po-Wei Cheng ◽  
Tzi-Dar Chiueh ◽  
Jyh-Horng Chen

Abstract Latest simultaneous multi-slice (SMS) methods greatly benefit MR efficiency for recent studies using parallel imaging technique. However, these methods are limited by the requirement of array coils. The proposed Coherent Wideband method, which employs an extended field of view to separate multiple excited slices, can be applied to any existing MRI instrument, even those without array coils. In this study, the Coherent Wideband echo-planar imaging method was implemented on 7T animal MRI to exhibit comprehensive enhancements in neuro-architecture, including diffusion tensor imaging (DTI) and functional MR studies (fMRI). Under the same scan time, the time-saving effect can be manipulated to increase the number of averages for DTI SNR improvement, reducing fractional anisotropy difference by 56.9% (from 0.072 to 0.041) and the deviation angle by 64% (from 25.3⁰ to 16.2⁰). In summary, Coherent Wideband EPI will provide faster, higher resolution, thinner slice, or higher SNR imaging for precision neuro-architecture studies.


2021 ◽  
Author(s):  
Po-Wei Cheng ◽  
Tzi-Dar Chiueh ◽  
Jyh-Horng Chen

Abstract Latest simultaneous multi-slice (SMS) methods greatly benefit MR efficiency for recent studies using parallel imaging technique. However, these methods are limited by the requirement of array coils. The proposed Coherent Wideband method, which employs an extended field of view to separate multiple excited slices, can be applied to any existing MRI instrument, even those without array coils. In this study, the Coherent Wideband echo-planar imaging method was implemented on 7T animal MRI to exhibit comprehensive enhancements in neuro-architecture, including diffusion tensor imaging (DTI) and functional MR studies (fMRI). Under the same scan time, the time-saving effect can be manipulated to increase the number of averages for DTI SNR improvement, reducing fractional anisotropy difference by 56.9% (from 0.072 to 0.041) and the deviation angle by 64% (from 25.3⁰ to 16.2⁰). In summary, Coherent Wideband EPI will provide faster, higher resolution, thinner slice, or higher SNR imaging for precision neuro-architecture studies.


2021 ◽  
Vol 8 ◽  
pp. 100327
Author(s):  
Daniel Stocker ◽  
Andrei Manoliu ◽  
Anton S. Becker ◽  
Borna K. Barth ◽  
Daniel Nanz ◽  
...  

2020 ◽  
Vol 85 (3) ◽  
pp. 1727-1741
Author(s):  
Ehsan Kazemivalipour ◽  
Alireza Sadeghi‐Tarakameh ◽  
Ergin Atalar

Author(s):  
Alireza Sadeghi-Tarakameh ◽  
Ehsan Kazemivalipour ◽  
Umut Gundogdu ◽  
Serhat Erdogan ◽  
Ergin Atalar

Sign in / Sign up

Export Citation Format

Share Document