maximum dose rate
Recently Published Documents


TOTAL DOCUMENTS

8
(FIVE YEARS 2)

H-INDEX

2
(FIVE YEARS 0)

2021 ◽  
Author(s):  
Ya-Dong Gao ◽  
De-Dong He ◽  
Ke Gong ◽  
Guang-Yu Shi ◽  
Si-Yuan Chen ◽  
...  

Abstract A prompt gamma neutron activation analysis (PGNAA) system based on a deuterium-deuterium (D-D) sealed neutron generator was designed using the MOCA code for explosive detection. The system is mainly composed of four parts: D-D sealed neutron generator, moderator, shielding, and Lutetium Yttrium OxyorthoSilicate (LYSO) scintillation detectors. Polyethylene (PE) was selected as the moderator and the optimal thickness was 7cm. Lead, PE, and boron-containing polyethylene were used as shielding materials. In the optimized model, the LYSO detector is used to measure eighteen materials, such as wood, melamine, glucose, and nylon, and so on. Firstly, the nitrogen characteristic peak of 10.8 MeV was analyzed to determine whether the material contained nitrogen. Then, the ratio of characteristic peak counts of C/O and O/N were calculated to distinguish explosives from nitrogen containing materials. Finally, dinitrobenzene, nitroglycerin, TNT, and ammonium nitrate can be separated from nitrogenous substances by a discriminant algorithm. The final device can be used to detect the chemical composition of the threat substances, and the maximum dose rate of the system meets the limits of international protection standards.


2018 ◽  
Vol 24 (2) ◽  
pp. 79-89 ◽  
Author(s):  
Karthick Raj Mani ◽  
Md Anisuzzaman Bhuiyan ◽  
Md. Shakilur Rahman ◽  
S. M. Azharur Islam

Abstract True Beam medical linear accelerator is capable of delivering flattening filter free (FFF) and with flattening filter (WFF) photon beams. True Beam linear accelerator is equipped with five photon beam energies (6 FFF, 6 WFF, 10 FFF, 10 WFF and 15 WFF) as well as six electron beam energies (6 MeV, 9 MeV, 12 MeV, 15 MeV and 18 MeV). The maximum dose rate for the 6 WFF, 10 WFF and 15 WFF is 600 MU/min, whereas 6 FFF has a maximum dose rate of 1400 MU/min and 10 FFF with a maximum dose rate of 2400 MU/min. In this report we discussed the open beam dosimetric characteristics of True Beam medical linear accelerator with FFF and WFF beam. All the dosimetric data (i.e. depth dose, cross-line profiles, diagonal profiles, output factors, MLC transmission, etc.) for 6 MV, 6 FFF, 10 MV, 10 FFF and 15 MV were measured and compared with the published data of the True Beam. Multiple detectors were used in order to obtain a consistent dataset. The measured data has a good consistency with the reference golden beam data. The measured beam quality index for all the beams are in good agreement with the published data. The percentage depth dose at 10 cm depth of all the available photon beams was within the tolerance of the Varian acceptance specification. The dosimetric data shows consistent and comparable results with the published data of other True Beam linear accelerators. The dosimetric data provide us an appreciated perception and consistent among the published data and may be used for future references.


2014 ◽  
Vol 99 (11) ◽  
pp. 4109-4115 ◽  
Author(s):  
Thomas Krohn ◽  
Heribert Hänscheid ◽  
Berthold Müller ◽  
Florian F. Behrendt ◽  
Alexander Heinzel ◽  
...  

1986 ◽  
Vol 16 (3) ◽  
pp. 561-571 ◽  
Author(s):  
Lee Brosan ◽  
Donald Broadbent ◽  
David Nutt ◽  
Margaret Broadbent

SynopsisSeven volunteers received diazepam for a 3-week period, maximum dose rate 25 mg per day, and were tested on a variety of functions before, at two points during, and at two points after the period. Their performance was compared with that of 8 controls and was inferior on a number of measures. There was no indication either of habituation or of potentiation of the effects as the period continued. Equally, the low performance persisted for some time after administration ceased, although performance was on the whole better than during the experimental period. The particular measures showing deterioration suggested that the effects are similar to those of barbiturates as opposed to those of, for example, chlorpromazine.


Sign in / Sign up

Export Citation Format

Share Document