poiseuille’s law
Recently Published Documents


TOTAL DOCUMENTS

47
(FIVE YEARS 4)

H-INDEX

10
(FIVE YEARS 1)

2020 ◽  
Vol 44 (3) ◽  
pp. 436-443
Author(s):  
Andrew P. Holmes ◽  
Clare J. Ray ◽  
Prem Kumar ◽  
Andrew M. Coney

The laboratory practical reported here is based in Poiseuille’s law and utilizes low-cost laboratory consumable items, thereby making it easy to deploy in any teaching laboratory. In the practical, students take an experimental approach of individually changing physical variables and measuring fluid flow rates. Plotting these results allows them to discuss the effect each variable has on flow. Furthermore, students enhance their appreciation of experimental errors and variability by making repeat measurements. In the follow-up teaching session, the students are encouraged to apply their experimental findings to the cardiovascular system and the control of blood flow both at rest and under conditions of altered cardiac output, such as during exercise. By tackling the topic of flow control as a core concept, it allows the students to then apply their understanding in wider physiological contexts, such as airflow in the respiratory system.


Transfusion ◽  
2020 ◽  
Vol 60 (7) ◽  
pp. 1410-1417
Author(s):  
David J. Berman ◽  
Adam Schiavi ◽  
Steven M. Frank ◽  
Shirley Duarte ◽  
Deborah A. Schwengel ◽  
...  

Perfusion ◽  
2019 ◽  
Vol 34 (1_suppl) ◽  
pp. 58-64 ◽  
Author(s):  
Lars Mikael Broman ◽  
Lisa Prahl Wittberg ◽  
C Jerker Westlund ◽  
Martijn Gilbers ◽  
Luisa Perry da Câmara ◽  
...  

Adequate extracorporeal membrane oxygenation support in the adult requires cannulae permitting blood flows up to 6-8 L/minute. In accordance with Poiseuille’s law, flow is proportional to the fourth power of cannula inner diameter and inversely proportional to its length. Poiseuille’s law can be applied to obtain the pressure drop of an incompressible, Newtonian fluid (such as water) flowing in a cylindrical tube. However, as blood is a pseudoplastic non-Newtonian fluid, the validity of Poiseuille’s law is questionable for prediction of cannula properties in clinical practice. Pressure–flow charts with non-Newtonian fluids, such as blood, are typically not provided by the manufacturers. A standardized laboratory test of return (arterial) cannulae for extracorporeal membrane oxygenation was performed. The aim was to determine pressure–flow data with human whole blood in addition to manufacturers’ water tests to facilitate an appropriate choice of cannula for the desired flow range. In total, 14 cannulae from three manufacturers were tested. Data concerning design, characteristics, and performance were graphically presented for each tested cannula. Measured blood flows were in most cases 3-21% lower than those provided by manufacturers. This was most pronounced in the narrow cannulae (15-17 Fr) where the reduction ranged from 27% to 40% at low flows and 5-15% in the upper flow range. These differences were less apparent with increasing cannula diameter. There was a marked disparity between manufacturers. Based on the measured results, testing of cannulae including whole blood flows in a standardized bench test would be recommended.


2018 ◽  
Vol 50 (5S) ◽  
pp. 181
Author(s):  
Francisco J. Morales ◽  
Brycen J. Ratcliffe ◽  
Caleb D. Harrison ◽  
Evan J. Bockover ◽  
Sierra Crowe ◽  
...  

2014 ◽  
Vol 29 (7) ◽  
pp. 1289-1289 ◽  
Author(s):  
Michiel F. Schreuder ◽  
Linda Koster-Kamphuis

Sign in / Sign up

Export Citation Format

Share Document