critical nozzles
Recently Published Documents


TOTAL DOCUMENTS

27
(FIVE YEARS 5)

H-INDEX

3
(FIVE YEARS 0)

2020 ◽  
Vol 24 (5 Part A) ◽  
pp. 2667-2687
Author(s):  
Zhipeng Xu ◽  
Feipeng Xu ◽  
Dailiang Xie

Piston prover has been widely used as a gas flow standard for its advantages of high accuracy in standard volume, flow stability and repeatability. It has also been employed as the primary gas flow standard in many countries to calibrate meters. However, it is difficult to ensure the uniformity of the inside dimension of the piston, thus the application of conventional piston provers are limited by the maximum calibration flow generated by the piston cylinder volume. In this paper, an improved piston gas prover that mainly consists of two uniform plungers was proposed. Their external diameter constitutes the flow standard. The plungers are driven by servo motor, and the high speed fieldbus EtherCAT has been introduced as the control unit. Hence the two pistons could work collaboratively and operate in three modes: single-piston mode, double-pistons parallel mode, and double-pistons reciprocating mode. Besides generating steady-flow rate, the double-plunger prover can even produce an unsteady-flow rate which could be used to research the dynamic characteristics of flow meters. The structure and working principle of the three modes were carefully introduced. Then experiments for calibrating critical nozzles were carried out, and the results show that the repeatability of the discharge coefficient could be better than 0.06%, and the pressure fluctuation during the process was less than 50 Pa.


2019 ◽  
Vol 62 (1) ◽  
pp. 54-58
Author(s):  
A. V. Mingaleev ◽  
A. I. Gorchev ◽  
A. B. Yakovlev
Keyword(s):  

ACTA IMEKO ◽  
2018 ◽  
Vol 7 (1) ◽  
pp. 68
Author(s):  
Oscar Yazit Salah García ◽  
Carlos Eduardo García Sánchez

<p class="Abstract">"PTB Testing Instructions, Volume 25: Gas meters – Test rigs with critical nozzles" (PTB 25) includes a detailed description of a test to evaluate the tightness of the rig (leak test). The mathematical modeling of this test assumes that temperature remains constant, and it is established a maximum allowable change of 0.1 K during the test. PTB 25 defines a maximum value of the leak flow rate as criteria for approval of the test.</p><p class="Abstract">In this work, the effect of the assumption of constant temperature over the leak test result was analyzed. Different processes in which the real leak flow rate was zero and there was a change in the temperature of the system equal to the maximum permissible (according to PTB 25) were simulated, and the leak flow rate calculated by PTB 25’s model was determined. The assumption of constant temperature does not simplifies drastically the mathematical model. It is concluded that PTB 25’s maximum allowable temperature change is too high for most practical situations, leading to errors that exceeds the maximum allowable leakage rate. The factors “test time” and “enclosed volume” have a high effect over the magnitude of the error given by PTB 25’s leak flow rate model.</p>


2017 ◽  
Vol 05 (02) ◽  
pp. 36-50 ◽  
Author(s):  
Soichiro Yagi ◽  
Saya Inoue ◽  
Shinichiro Nakao ◽  
Daisuke Ono ◽  
Yoshiaki Miyazato