Fluorescence-based fouling prediction and optimization of a membrane filtration process for drinking water treatment

AIChE Journal ◽  
2011 ◽  
Vol 58 (5) ◽  
pp. 1475-1486 ◽  
Author(s):  
Ramila H. Peiris ◽  
Hector Budman ◽  
Christine Moresoli ◽  
Raymond L. Legge
2020 ◽  
Vol 24 (3) ◽  
pp. 19-23 ◽  
Author(s):  
A.S. Kutergin ◽  
T.A. Nedobukh

The possibilities of using natural granular glauconite in standard water treatment schemes have been investigated. Resource tests of the studied material were carried out in dynamics, simulating possible conditions of use. As a result of the experiments, it was established: during the filtration process, alkalization of water occurs, but the result does not exceed pH = 6÷9, which are the norm for drinking water; the use of a sorbent based on natural glauconite does not impair the hardness indicator of the treated water. The dynamic exchange capacity was: for iron – 3.09 mg/g of absorbent, copper – 19.15 mg/g of absorbent, zinc – 4.82 mg/g of absorbent. The resource of the filter was determined with the loading of granulate with a volume of 1 dm3: for iron – 2918 dm3, for copper – 5425 dm3, for zinc – 273 dm3. The mechanical strength acquired by the sorbent as a result of granulation made it possible to wash the load by the countercurrent method, freeing intergranular pores from the sediment accumulated in them. The revealed capabilities of granular glauconite will allow its use in drinking water treatment schemes for purifying natural waters from heavy metals: iron, zinc, copper.


Membranes ◽  
2021 ◽  
Vol 11 (8) ◽  
pp. 643
Author(s):  
Hongjian Yu ◽  
Weipeng Huang ◽  
Huachen Liu ◽  
Tian Li ◽  
Nianping Chi ◽  
...  

The combination of conventional and advanced water treatment is now widely used in drinking water treatment. However, membrane fouling is still the main obstacle to extend its application. In this study, the impact of the combination of coagulation and ultrafiltration (UF) membrane rotation on both fouling control and organic removal of macro (sodium alginate, SA) and micro organic matters (tannic acid, TA) was studied comprehensively to evaluate its applicability in drinking water treatment. The results indicated that membrane rotation could generate shear stress and vortex, thus effectively reducing membrane fouling of both SA and TA solutions, especially for macro SA organics. With additional coagulation, the membrane fouling could be further reduced through the aggregation of mediate and macro organic substances into flocs and elimination by membrane retention. For example, with the membrane rotation speed of 60 r/min, the permeate flux increased by 90% and the organic removal by 35% in SA solution, with 40 mg/L coagulant dosage, with an additional 70% increase of flux and 5% increment of organic removal to 80% obtained. However, too much shear stress could intensify the potential of fiber breakage at the potting, destroying the flocs and resulting in the reduction of permeate flux and deterioration of effluent quality. Finally, the combination of coagulation and membrane rotation would lead to the shaking of the cake layer, which is beneficial for fouling mitigation and prolongation of membrane filtration lifetime. This study provides useful information on applying the combined process of conventional coagulation and the hydrodynamic shear force for drinking water treatment, which can be further explored in the future.


2021 ◽  
Vol 755 ◽  
pp. 142658
Author(s):  
Haojie Ding ◽  
Jian Zhang ◽  
Huan He ◽  
Ying Zhu ◽  
Dionysios D. Dionysiou ◽  
...  

2015 ◽  
Vol 156 ◽  
pp. 165-174 ◽  
Author(s):  
Joao Mimoso ◽  
Wouter Pronk ◽  
Eberhard Morgenroth ◽  
Frederik Hammes

Sign in / Sign up

Export Citation Format

Share Document