Bioanalytical method development, validation and quantification of dorsomorphin in rat plasma by LC-MS/MS

2013 ◽  
pp. n/a-n/a
Author(s):  
K. Karthikeyan ◽  
Mahamad Yunnus A. Mahat ◽  
S. Chandrasekaran ◽  
K. Gopal ◽  
P. X. Franklin ◽  
...  
Molecules ◽  
2020 ◽  
Vol 25 (12) ◽  
pp. 2800
Author(s):  
Hyun Wook Huh ◽  
Hee-Yong Song ◽  
Young-Guk Na ◽  
Minki Kim ◽  
Mingu Han ◽  
...  

A simple, sensitive, and rapid UHPLC-MS/MS method was developed for the simultaneous determination of veratraldehyde and its metabolite veratric acid in rat plasma. Cinnamaldehyde was used as an internal standard (IS) and the one-step protein precipitation method with 0.2% formic acid in acetonitrile (mobile phase B) was used for the sample extraction. Reversed C18 column (YMC-Triart C18 column, 50 mm × 2.0 mm, 1.9 µm) was used for chromatographic separation and was maintained at 30 °C. The total run time was 4.5 min and the electrospray ionization in positive mode was used with the transition m/z 167.07 → 139.00 for veratraldehyde, m/z 183.07 → 139.00 for veratric acid, and m/z 133.00 → 55.00 for IS. The developed method exhibited good linearity (r2  ≥  0.9977), and the lower limits of quantification ranged from 3 to 10 ng/mL for the two analytes. Intra-day precision and accuracy parameters met the criteria (within ±15%) during the validation. The bioanalytical method was applied for the determination of veratraldehyde and veratric acid in rat plasma after oral and percutaneous administration of 300 and 600 mg/kg veratraldehyde. Using the analytical methods established in this study, we can confirm the absorption and metabolism of veratraldehyde in rats for various routes.


Sign in / Sign up

Export Citation Format

Share Document