scholarly journals Luminescent PMMA Films and PMMA@SiO2 Nanoparticles with Embedded Ln3+ Complexes for Highly Sensitive Optical Thermometers in the Physiological Temperature Range

Author(s):  
Dimitrije Mara ◽  
Anna M. Kaczmarek ◽  
Flavia Artizzu ◽  
Anatolii Abalymov ◽  
Andre G. Skirtach ◽  
...  
2017 ◽  
Vol 19 (10) ◽  
pp. 7343-7351 ◽  
Author(s):  
L. Marciniak ◽  
A. Bednarkiewicz ◽  
J. Drabik ◽  
K. Trejgis ◽  
W. Strek

The highest relative sensitivity of YAG:Cr3+,Nd3+ luminescent thermometers in physiological temperature range was 3.48% K−1.


2004 ◽  
Vol 396 (1-6) ◽  
pp. 258-259 ◽  
Author(s):  
A. A. Kudryavtsev ◽  
V. P. Lavrovskaya ◽  
I. I. Popova ◽  
E. I. Lezhnev ◽  
L. M. Chailakhyan

2018 ◽  
Vol 6 (41) ◽  
pp. 11178-11183 ◽  
Author(s):  
Yan Gao ◽  
Yao Cheng ◽  
Tao Hu ◽  
Zeliang Ji ◽  
Hang Lin ◽  
...  

This study highlights a highly sensitive dual-mode optical thermometer Pr3+:Gd2ZnTiO6 for thermal readings over a wide range of temperature.


2014 ◽  
Vol 2014 (1) ◽  
pp. 000500-000504 ◽  
Author(s):  
Francy J. Akkara ◽  
Uday S. Goteti ◽  
Richard C. Jaeger ◽  
Michael C. Hamilton ◽  
Michael J. Palmer ◽  
...  

In certain applications, IC packages may be exposed to extreme temperatures and knowledge of thermally induced stress aids the prediction of performance degradation or failure of the IC. In the devices that are used in extreme conditions, the stress is caused mainly by the mismatch in expansion of various materials triggered by the different coefficients of thermal expansion. This work performed in this study is conducted using NMOS current mirror circuits that are cycled through a wide temperature range of −180°C to 80°C. These circuits are highly sensitive to stress and provide well-localized measurements of shear stress. The sensors are fabricated in such a way that the effects of certain stress components are isolated. These sensors are also temperature compensated so that only the effect of mechanical stress components is observed and changes in device performance due to temperature changes are minimal. Current readings obtained from the sensors are used to extract the shear stress component. Finite element simulations, using expected materials performance parameter information were also performed for similar packages and these results are compared to the measured results.


2020 ◽  
Vol 306 ◽  
pp. 112818 ◽  
Author(s):  
V. Bardik ◽  
Anatoliy I. Fisenko ◽  
Salvatore Magazu ◽  
Nikolay P. Malomuzh

2019 ◽  
Vol 55 (24) ◽  
pp. 3509-3512 ◽  
Author(s):  
Sen Liang ◽  
Yuan Wang ◽  
Xueke Wu ◽  
Min Chen ◽  
Lixuan Mu ◽  
...  

We report here an ultrasensitive ratiometric fluorescent thermometer (RFT) based on the frustrated static excimers (FSEs) of DEH-PDI (N,N′-di(2-ethylhexyl)-3,4,9,10-perylenetetracarboxylic diimide) in the physiological temperature range.


2019 ◽  
Vol 7 (35) ◽  
pp. 10972-10980 ◽  
Author(s):  
Flore Vanden Bussche ◽  
Anna M. Kaczmarek ◽  
Johannes Schmidt ◽  
Christian V. Stevens ◽  
Pascal Van Der Voort

Grafting of an insoluble phenanthroline-polymer with Eu3+/Tb3+ tfac complexes creates a thermometer with good temperature sensitivity in the broad biological range.


Nanoscale ◽  
2013 ◽  
Vol 5 (21) ◽  
pp. 10369 ◽  
Author(s):  
Wei Wang ◽  
Prakash D. Nallathamby ◽  
Carmen M. Foster ◽  
Jennifer L. Morrell-Falvey ◽  
Ninell P. Mortensen ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document