Morphological characteristics of total joint arthroplasty-derived ultra-high molecular weight polyethylene (UHMWPE) wear debris that provoke inflammation in a murine model of inflammation

2003 ◽  
Vol 64A (3) ◽  
pp. 457-464 ◽  
Author(s):  
Allison Sieving ◽  
Bin Wu ◽  
Lois Mayton ◽  
Sam Nasser ◽  
Paul H. Wooley
Author(s):  
J L Hailey ◽  
E Ingham ◽  
M Stone ◽  
B M Wroblewski ◽  
J Fisher

The objective of this study was to investigate the effect of counterface roughness and lubricant on the morphology of ultra-high molecular weight polyethylene (UHMWPE) wear debris generated in laboratory wear tests, and to compare this with debris isolated from explanted tissue. Laboratory tests used UHMWPE pins sliding against stainless steel counterfaces. Both water and serum lubricants were used in conjunction with rough and smooth counterfaces. The lubricants and tissue from revision hip surgery were processed to digest the proteins and permit filtration. This involved denaturing the proteins with potassium hydroxide (KOH), sedimentation of any remaining proteins, and further digestion of these proteins with chromic acid. All fractions were then passed through a 0.2 μm membrane, and the debris examined using scanning electron microscopy. The laboratory studies showed that the major variable influencing debris morphology was counterface roughness. The rougher counter-faces produced larger numbers of smaller particles, with a size range extending below 1 μm. For smooth counterfaces there were fewer of these small particles, and evidence of larger platelets, greater than 10 μm in diameter. Analysis of the debris from explanted tissues showed a wide variation in the particle size distribution, ranging from below 1 μm up to several millimetres in size. Of major clinical significance in relation to osteolysis and loosening is roughening of the femoral components, which may lead to greater numbers of the sub-micron-sized particles.


Wear ◽  
2009 ◽  
Vol 266 (1-2) ◽  
pp. 349-355 ◽  
Author(s):  
Monika Lapcikova ◽  
Miroslav Slouf ◽  
Jiri Dybal ◽  
Eva Zolotarevova ◽  
Gustav Entlicher ◽  
...  

2003 ◽  
Vol 125 (3) ◽  
pp. 638-642 ◽  
Author(s):  
Vesa Saikko

In the wear testing of prosthetic joints, the optimal lubricant protein concentration is disputed. The effect of protein concentration of calf serum based lubricant on the wear of ultra-high molecular weight polyethylene against CoCr was studied with a 12-station, circularly translating pin-on-disk device. The wear factor first steeply increased with increasing concentration, reached a peak at 10–20 mg/ml, and then slowly decreased. Below 20 mg/ml, the wear mechanisms were not entirely representative of clinical wear. Above this value, the morphology of the UHMWPE wear surface resembled that of retrieved cups. The results indicated that the concentration should not be below 20 mg/ml. The scope of this recommendation is discussed.


Author(s):  
Takuya NANBU ◽  
Tatsuki MATSUURA ◽  
Yoshitaka NAKANISHI ◽  
Mutsumi TOUGE ◽  
Hiroshi MIZUTA ◽  
...  