scholarly journals Effect of stress‐shielding‐induced bone resorption on glenoid loosening in reverse total shoulder arthroplasty

2020 ◽  
Vol 38 (7) ◽  
pp. 1566-1574 ◽  
Author(s):  
Min Zhang ◽  
Thomas Gregory ◽  
Ulrich Hansen ◽  
Cheng‐Kung Cheng
Author(s):  
Heath B. Henninger ◽  
Michael D. Harris ◽  
Kristen R. Petersen ◽  
Robert T. Burks ◽  
Robert Z. Tashjian

Scapular notching is a complication of reverse total shoulder arthroplasty (rTSA) that results in bone loss on the lateral border of the scapula. Notching has been reported in up to 86% of patients at 5 year follow-up [1], and is graded 1–4 as a function of progressive bone loss [2]. Notching may arise from impingement, erosion, periprosthetic osteolysis, stress shielding or a combination of these [1]. Glenosphere position can mitigate notching by limiting hardware impingement [3–5], but may increase the forces required to abduct the arm [6]. Clinicians might optimize patient range of motion and function via implant placement if susceptibility to notching was known a-priori.


2022 ◽  
Vol 23 (1) ◽  
Author(s):  
Hyojune Kim ◽  
Chul-Ho Kim ◽  
Minsoo Kim ◽  
Wonsun Lee ◽  
In-Ho Jeon ◽  
...  

Abstract Purpose We aimed to compare the outcomes and complications of anatomical shoulder arthroplasty (aTSA) and reverse total shoulder arthroplasty (rTSA) for primary glenohumeral osteoarthritis with intact cuff tissue. Materials and methods The MEDLINE, Embase, and Cochrane Library databases were systematically searched for studies published before March 2, 2021 using the PRISMA guidelines. Studies were included if they directly compared aTSA and rTSA for treating primary glenohumeral arthritis. A meta-analysis was performed using six studies that compared radiologic outcomes, functional scores, and range of motion (ROM). All the data were pooled using a random-effects model. Odds ratios (ORs) and 95% confidence intervals (CIs) were calculated as dichotomous data, while continuous data were analyzed using mean differences with 95% CIs. Results Two independent researchers reviewed 1,061 studies. Six studies met the inclusion criteria. The range of motion, especially external rotation, was better for aTSA than for rTSA (MD = − 10.28, 95% CI: − 16.69 to − 3.88, P = 0.002). Functional scores showed no difference between aTSA and rTSA. Glenoid loosening (OR = 0.17, 95% CI: 0.06–0.50, P = 0.001) was more common with aTSA, and scapula notching (OR = 10.63, 95% CI: 1.73–65.27, P = 0.01) with rTSA. In the mid-term follow-up, the overall revision rate showed no difference between aTSA and rTSA, with a pooled OR of 0.33 (95% CI: 0.07–1.57, P = 0.16). Conclusion A better ROM was achieved after aTSA than after rTSA. There was no difference in the revision rate at mid-term follow-up between aTSA and rTSA. Glenoid loosening was more common with aTSA, and scapula notching with rTSA. Level of evidence: Level IV, Meta-analysis.


2021 ◽  
Vol 103-B (8) ◽  
pp. 1333-1338
Author(s):  
Pradeep Kankanalu ◽  
Zakk M. Borton ◽  
Marie L. Morgan ◽  
Tim Cresswell ◽  
Marius P. Espag ◽  
...  

Aims Reverse total shoulder arthroplasty (RTSA) using trabecular metal (TM)-backed glenoid implants has been introduced with the aim to increase implant survival. Only short-term reports on the outcomes of TM-RTSA have been published to date. We aim to present the seven-year survival of TM-backed glenoid implants along with minimum five-year clinical and radiological outcomes. Methods All consecutive elective RTSAs performed at a single centre between November 2008 and October 2014 were reviewed. Patients who had primary TM-RTSA for rotator cuff arthropathy and osteoarthritis with deficient cuff were included. A total of 190 shoulders in 168 patients (41 male, 127 female) were identified for inclusion at a mean of 7.27 years (SD 1.4) from surgery. The primary outcome was survival of the implant with all-cause revision and aseptic glenoid loosening as endpoints. Secondary outcomes were clinical, radiological, and patient-related outcomes with a five-year minimum follow-up. Results The implant was revised in ten shoulders (5.2%) with a median time to revision of 21.2 months (interquartile range (IQR) 9.9 to 41.8). The Kaplan-Meier survivorship estimate at seven years was 95.9% (95% confidence interval (CI) 91.7 to 98; 35 RTSAs at risk) for aseptic mechanical failure of the glenoid and 94.8% (95% CI 77.5 to 96.3; 35 RTSAs at risk) for all-cause revision. Minimum five-year clinical and radiological outcomes were available for 103 and 98 RTSAs respectively with a median follow-up time of six years (IQR 5.2 to 7.0). Median postoperative Oxford Shoulder Score was 38 (IQR 31 to 45); median Constant and Murley score was 60 (IQR 47.5 to 70); median forward flexion 115° (IQR 100° to 125°); median abduction 95° (IQR 80° to 120°); and external rotation 25° (IQR 15° to 40°) Scapular notching was seen in 62 RTSAs (63.2%). Conclusion We present the largest and longest-term series of TM-backed glenoid implants demonstrating 94.8% all-cause survivorship at seven years. Specifically pertaining to glenoid loosening, survival of the implant increased to 95.9%. In addition, we report satisfactory minimum five-year clinical and radiological outcomes. Cite this article: Bone Joint J 2021;103-B(8):1333–1338.


2021 ◽  
pp. 175857322110193
Author(s):  
Arjun K Reddy ◽  
Jake X Checketts ◽  
B Joshua Stephens ◽  
J Michael Anderson ◽  
Craig M Cooper ◽  
...  

Background Thus, the purpose of the present study was to (1) characterize common postoperative complications and (2) quantify the rates of revision in patients undergoing hemiarthroplasty to reverse total shoulder arthroplasty revisional surgery. We hypothesize that hardware loosenings will be the most common complication to occur in the sample, with the humeral component being the most common loosening. Methods This systematic review adhered to PRISMA reporting guideline. For our inclusion criteria, we included any study that contained intraoperative and/or postoperative complication data, and revision rates on patients who had undergone revision reverse total shoulder arthroplasty due to a failed hemiarthroplasty. Complications include neurologic injury, deep surgical site infections, hardware loosening/prosthetic instability, and postoperative fractures (acromion, glenoid, and humeral fractures). Results The study contained 22 studies that assessed complications from shoulders that had revision reverse total shoulder arthroplasty from a hemiarthroplasty, with a total sample of 925 shoulders. We found that the most common complication to occur was hardware loosenings (5.3%), and of the hardware loosenings, humeral loosenings (3.8%) were the most common. The revision rate was found to be 10.7%. Conclusion This systematic review found that revision reverse total shoulder arthroplasty for failed hemiarthroplasty has a high overall complication and reintervention rates, specifically for hardware loosening and revision rates.


2021 ◽  
pp. 175857322110329
Author(s):  
Therese E Parr ◽  
Jennifer K Anderson ◽  
Alan M. Marionneaux ◽  
John M Tokish ◽  
Stefan J Tolan ◽  
...  

Background In a reverse total shoulder arthroplasty, the altered glenohumeral joint center of rotation subjects the glenoid baseplate to increased shear forces and potential loosening. Methods This study examined glenoid baseplate micromotion and initial fixation strength with the application of direct shear force in a Sawbone model. The reverse total shoulder arthroplasty systems examined were the DJO Reverse® Shoulder Prosthesis, the Exactech Equinoxe® Reverse System, and the Tornier AequalisTM Reverse Shoulder Prosthesis. Specimens were cyclically tested with increasing shear loads until 150 µm of displacement between the implant and glenoid was achieved, and subsequently until failure, classified as either 1 cm of implant/glenoid displacement or fracture. Results The average load withstood for the 150 µm threshold for DJO, Tornier, and Exactech was 460 ± 88 N, 525 ± 100 N, and 585 ± 160 N, respectively. The average total load at device failure for DJO, Tornier, and Exactech was 980 ± 260 N, 1260 ± 120 N, and 1350 ± 230 N, respectively. Discussion The Exactech implant design trended toward requiring more load to induce micromotion at each threshold and to induce device failure, most commonly seen as inferior screw pull out. This study proposes design features that may enhance fixation and suggests little risk of initial micromotion or failure during initial post-operative recovery.