Ultimate load behaviour of reinforced concrete plates and shells under dynamic transient loading

1986 ◽  
Vol 22 (1) ◽  
pp. 189-208 ◽  
Author(s):  
G. Q. Liu ◽  
D. R. J. Owen
2020 ◽  
Vol 38 (5A) ◽  
pp. 669-680
Author(s):  
Ghazwan K. Mohammed ◽  
Kaiss F. Sarsam ◽  
Ikbal N. Gorgis

The study deals with the effect of using Slurry infiltrated fiber concrete (SIFCON) with the reinforced concrete beams to explore its enhancement to the flexural capacity. The experimental work consists of the casting of six beams, two beams were fully cast by conventional concrete (CC) and SIFCON, as references. While the remaining was made by contributing a layer of SIFCON diverse in-depth and position, towards complete the overall depths of the built-up beam with conventional concrete CC. Also, an investigation was done through the control specimens testing about the mechanical properties of SIFCON. The results showed a stiffer behavior with a significant increase in load-carrying capacity when SIFCON used in tension zones. Otherwise high ductility and energy dissipation appeared when SIFCON placed in compression zones with a slight increment in ultimate load. The high volumetric ratio of steel fibers enabled SIFCON to magnificent tensile properties.


2013 ◽  
Vol 66 (4) ◽  
pp. 425-430 ◽  
Author(s):  
Jorge Luis Palomino Tamayo ◽  
Armando Miguel Awruch ◽  
Inácio Benvegnu Morsch

A numerical model using the Finite Element Method (FEM) for the nonlinear static and dynamic analysis of reinforced concrete (RC) beams, plates and shells is presented in this work. For this purpose, computer programs based on plasticity theory and with crack monitoring capabilities are developed. The static analysis of RC shells up to failure load is carried out using 9-node degenerated shell finite elements while 20-node brick finite elements are used for dynamic applications. The elasto-plastic constitutive law for concrete is coupled with a strain-rate sensitive model in order to take into account high loading rate effect when transient loading is intended. The implicit Newmark scheme with predictor and corrector phases is used for time integration of the nonlinear system of equations. In both cases, the steel reinforcement is considered to be smeared and represented by membrane finite elements. Various benchmark examples are solved with the present numerical model and comparisons with other published data are performed. For all examples, the path failure, collapse loads and failure mechanism is reproduced with great accuracy.


2013 ◽  
Vol 6 (5) ◽  
pp. 737-750
Author(s):  
R. Barros ◽  
J.S. Giongo

On Precast concrete structures the column foundation connections can occur through the socket foundation, which can be embedded, partially embedded or external, with socket walls over the pile caps. This paper presents an experimental study about two pile caps reinforced concrete with external, partially embedded and embedded socket submitted to central load, using 1:2 scaled models. In the analyzed models, the smooth interface between the socket walls and column was considered. The results are compared to a reference model that presents monolithic connections between the column and pile cap. It is observed that the ultimate load of pile cap with external sockets has the same magnitude as the reference pile cap, but the ultimate load of models with partially embedded and embedded socket present less magnitude than the reference model.


2010 ◽  
Vol 3 (3) ◽  
pp. 271-283 ◽  
Author(s):  
M. Y. M. Omar ◽  
R. B. Gomes ◽  
A. P. A. Reis

This paper presents the results of reinforced concrete columns strengthened by addition of a self-compacting concrete overlay at the compressed and at the tensioned face of the member, with and without addition of longitudinal steel bars. Eight columns were submit- ted to loading with an initial eccentricity of 60 mm . These columns had 120 mm x 250 mm of rectangular cross section, 2000 mm in length and four longitudinal reinforcement steel bars with 10 mm in diameter. Reference columns P1 and P2 were tested to failure without any type of rehabilitation. Columns P3 to P8 were loaded to a predefined load (close to the initial yield point of tension reinforce- ment), then unloaded and strengthened for a subsequent test until failure. Results showed that the method of rehabilitation used was effective, increasing the loading capacity of the strengthened pieces by 2 to 5 times the ultimate load of the reference column.


Sign in / Sign up

Export Citation Format

Share Document