scholarly journals Proteomic analysis of formalin‐fixed paraffin‐embedded renal tissue samples by label‐free MS: Assessment of overall technical variability and the impact of block age

2013 ◽  
Vol 7 (3-4) ◽  
pp. 273-282 ◽  
Author(s):  
Rachel A. Craven ◽  
David A. Cairns ◽  
Alexandre Zougman ◽  
Patricia Harnden ◽  
Peter J. Selby ◽  
...  
Author(s):  
Robin Verjans ◽  
Annette H. Bruggink ◽  
Robby Kibbelaar ◽  
Jos Bart ◽  
Aletta Debernardi ◽  
...  

AbstractBiobanks play a crucial role in enabling biomedical research by facilitating scientific use of valuable human biomaterials. The PALGA foundation—a nationwide network and registry of histo- and cytopathology in the Netherlands—was established to promote the provision of data within and between pathology departments, and to make the resulting knowledge available for healthcare. Apart from the pathology data, we aimed to utilize PALGA’s nationwide network to find and access the rich wealth of Formalin-Fixed Paraffin-Embedded (FFPE) tissue samples for scientific use.  We implemented the Dutch National TissueArchive Portal (DNTP) to utilize PALGA’s nationwide network for requesting FFPE tissue samples. The DNTP consists of (1) a centrally organized internet portal to improve the assessing, processing, harmonization, and monitoring of the procurement process, while (2) dedicated HUB-employees provide practical support at peripheral pathology departments. Since incorporation of the DNTP, both the number of filed requests for FFPE tissue samples and the amount of HUB-mediated support increased 55 and 29% respectively. In line, the sample procurement duration time decreased significantly (− 47%). These findings indicate that implementation of the DNTP improved the frequency, efficiency, and transparency of FFPE tissue sample procurement for research in the Netherlands. To conclude, the need for biological resources is growing persistently to enable precision medicine. Here, we access PALGA’s national, pathology network by implementation of the DNTP to allow for efficient, consistent, and transparent exchange of FFPE tissue samples for research across the Netherlands.


BMC Cancer ◽  
2019 ◽  
Vol 19 (1) ◽  
Author(s):  
Michal Marczyk ◽  
Chunxiao Fu ◽  
Rosanna Lau ◽  
Lili Du ◽  
Alexander J. Trevarton ◽  
...  

Abstract Background Utilization of RNA sequencing methods to measure gene expression from archival formalin-fixed paraffin-embedded (FFPE) tumor samples in translational research and clinical trials requires reliable interpretation of the impact of pre-analytical variables on the data obtained, particularly the methods used to preserve samples and to purify RNA. Methods Matched tissue samples from 12 breast cancers were fresh frozen (FF) and preserved in RNAlater or fixed in formalin and processed as FFPE tissue. Total RNA was extracted and purified from FF samples using the Qiagen RNeasy kit, and in duplicate from FFPE tissue sections using three different kits (Norgen, Qiagen and Roche). All RNA samples underwent whole transcriptome RNA sequencing (wtRNAseq) and targeted RNA sequencing for 31 transcripts included in a signature of sensitivity to endocrine therapy. We assessed the effect of RNA extraction kit on the reliability of gene expression levels using linear mixed-effects model analysis, concordance correlation coefficient (CCC) and differential analysis. All protein-coding genes in the wtRNAseq and three gene expression signatures for breast cancer were assessed for concordance. Results Despite variable quality of the RNA extracted from FFPE samples by different kits, all had similar concordance of overall gene expression from wtRNAseq between matched FF and FFPE samples (median CCC 0.63–0.66) and between technical replicates (median expression difference 0.13–0.22). More than half of genes were differentially expressed between FF and FFPE, but with low fold change (median |LFC| 0.31–0.34). Two out of three breast cancer signatures studied were highly robust in all samples using any kit, whereas the third signature was similarly discordant irrespective of the kit used. The targeted RNAseq assay was concordant between FFPE and FF samples using any of the kits (CCC 0.91–0.96). Conclusions The selection of kit to purify RNA from FFPE did not influence the overall quality of results from wtRNAseq, thus variable reproducibility of gene signatures probably relates to the reliability of individual gene selected and possibly to the algorithm. Targeted RNAseq showed promising performance for clinical deployment of quantitative assays in breast cancer from FFPE samples, although numerical scores were not identical to those from wtRNAseq and would require calibration.


2021 ◽  
pp. jclinpath-2021-207723
Author(s):  
Paola Rafaniello-Raviele ◽  
Ilaria Betella ◽  
Alessandra Rappa ◽  
Davide Vacirca ◽  
Gianluca Tolva ◽  
...  

AimsAnalysis of microsatellite instability (MSI) is strongly recommended in endometrial cancer (EC) and colorectal cancer to screen for Lynch syndrome, to predict prognosis and to determine optimal treatment and follow-up. In a large monoinstitutional series of ECs, we evaluated the reliability and accuracy of Idylla assay, a rapid, fully automated system to detect MSI, and we compared its performance with two routine reference methods.MethodsWe evaluated MSI status in 174 formalin-fixed, paraffin-embedded EC tissue samples using immunohistochemistry (IHC) for mismatch repair (MMR) proteins and Idylla assay. Samples with discordant or equivocal results were analysed with a third technique, the Promega MSI kit.ResultsIdylla MSI assay and IHC were highly concordant (overall agreement: 154/170=90.59%, 95% CI 85.26% to 94.12%). However, in four samples, MMR-IHC staining was equivocal; moreover, 16 cases showed discordant results, that is, MMR deficient using IHC and microsatellite stable using Idylla. These 20 samples were reanalysed using the MSI-Promega kit, which showed the same results of Idylla assay in 18/20 cases (overall agreement: 90%, 95% CI 69.90% to 97.21%).ConclusionsOur results suggest that IHC is an efficient method to determine MMR status in ECs. However, the Idylla MSI assay is a rapid and reliable tool to define MSI status, and it could represent a valuable alternative to conventional MSI-PCR methods.


2014 ◽  
Vol 8 (9-10) ◽  
pp. 796-804 ◽  
Author(s):  
Peter Bronsert ◽  
Juliane Weißer ◽  
Martin L. Biniossek ◽  
Markus Kuehs ◽  
Bettina Mayer ◽  
...  

2008 ◽  
Vol 1 (1) ◽  
pp. 40-45 ◽  
Author(s):  
Mohit Raja Jain ◽  
Tong Liu ◽  
Jun Hu ◽  
Marlene Darfler ◽  
Valerie Fitzhugh ◽  
...  

2021 ◽  
Vol 45 (4) ◽  
pp. 262-267
Author(s):  
Yılmaz Baş ◽  
Yunus Emre Beyhan ◽  
Havva Hande Keser Şahin ◽  
Tuğba Özçerezci ◽  
Dursun Karasartova ◽  
...  

2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Pauline Gilson ◽  
Julien Levy ◽  
Marie Rouyer ◽  
Jessica Demange ◽  
Marie Husson ◽  
...  

Abstract Microsatellite instability (MSI) status is routinely assessed in patients with colorectal and endometrial cancers as it contributes to Lynch syndrome initial screening, tumour prognosis and selecting patients for immunotherapy. Currently, standard reference methods recommended for MSI/dMMR (deficient MisMatch Repair) testing consist of immunohistochemistry and pentaplex PCR-based assays, however, novel molecular-based techniques are emerging. Here, we aimed to evaluate the performance of a custom capture-based NGS method and the Bio-Rad ddPCR and Idylla approaches for the determination of MSI status for theranostic purposes in 30 formalin-fixed paraffin embedded (FFPE) tissue samples from patients with endometrial (n = 15) and colorectal (n = 15) cancers. All samples were previously characterised using IHC and Promega MSI Analysis System and these assays set as golden standard. Overall agreement, sensitivity and specificity of our custom-built NGS panel were 93.30%, 93.75% and 92.86% respectively. Overall agreement, sensitivity and specificity were 100% with the Idylla MSI system. The Bio-Rad ddPCR MSI assay showed a 100% concordance, sensitivity and specificity. The custom capture-based NGS, Bio-Rad ddPCR and Idylla approaches represent viable and complementary options to IHC and Promega MSI Analysis System for the detection of MSI. Bio-Rad ddPCR and Idylla MSI assays accounts for easy and fast screening assays while the NGS approach offers the advantages to simultaneously detect MSI and clinically relevant genomic alterations.


Sign in / Sign up

Export Citation Format

Share Document