Median‐rate control chart for simultaneous monitoring of frequency and magnitude of events

Author(s):  
Nasim Amjadi ◽  
Kamyar Sabri‐Laghaie
2021 ◽  
Vol 2021 ◽  
pp. 1-10
Author(s):  
Shan Lin ◽  
Liping Liu ◽  
Meiwan Rao ◽  
Shu Deng ◽  
Jiaxin Wang ◽  
...  

To make accurate and comprehensive evaluation of the catenary and diagnose the causes of the catenary fault, a method of catenary state evaluation and diagnosis based on the principal component analysis control chart was proposed, which can make full use of the multidimensional detection parameters of the catenary. The principal component analysis was used to reduce the dimension of catenary parameters, the principal component T2 control chart was calculated to show the change of principal component of catenary state data, the residual SPE control chart was calculated to show the change of their correlation, and the contribution rate control chart was calculated to show the cause of abnormal state data. The method can not only transform the multidimensional detection parameters of the catenary into a statistic to realize the simple and intuitive evaluation of the catenary state but also can accurately determine the cause of the abnormal state, so as to provide technical support for the targeted condition-based maintenance of the catenary.


2007 ◽  
Author(s):  
E. S. Gevorkyan ◽  
S. M. Minasyan ◽  
N. N. Ksadjikyan ◽  
A. V. Dayan ◽  
TsI Adamyan

TAPPI Journal ◽  
2018 ◽  
Vol 17 (05) ◽  
pp. 295-305
Author(s):  
Wesley Gilbert ◽  
Ivan Trush ◽  
Bruce Allison ◽  
Randy Reimer ◽  
Howard Mason

Normal practice in continuous digester operation is to set the production rate through the chip meter speed. This speed is seldom, if ever, adjusted except to change production, and most of the other digester inputs are ratioed to it. The inherent assumption is that constant chip meter speed equates to constant dry mass flow of chips. This is seldom, if ever, true. As a result, the actual production rate, effective alkali (EA)-to-wood and liquor-to-wood ratios may vary substantially from assumed values. This increases process variability and decreases profits. In this report, a new continuous digester production rate control strategy is developed that addresses this shortcoming. A new noncontacting near infrared–based chip moisture sensor is combined with the existing weightometer signal to estimate the actual dry chip mass feedrate entering the digester. The estimated feedrate is then used to implement a novel feedback control strategy that adjusts the chip meter speed to maintain the dry chip feedrate at the target value. The report details the results of applying the new measurements and control strategy to a dual vessel continuous digester.


2019 ◽  
Vol 139 (8) ◽  
pp. 889-890
Author(s):  
Takao Sato ◽  
Natsuki Kawaguchi ◽  
Nozomu Araki ◽  
Yasuo Konishi

Sign in / Sign up

Export Citation Format

Share Document