scholarly journals Direct evaporative cooling from wetted surfaces: Challenges for a clean air conditioning solution

Author(s):  
Ana Tejero‐González ◽  
Antonio Franco‐Salas
2003 ◽  
Vol 2 (2) ◽  
Author(s):  
J. R. Camargo ◽  
C. D. Ebinuma ◽  
S. Cardoso

Air conditioning systems are responsible for increasing men's work efficiency as well for his comfort, mainly in the warm periods of the year. Currently, the most used system is the mechanical vapor compression system. However, in many cases, evaporative cooling system can be an economical alternative to replace the conventional system, under several conditions, or as a pre-cooler in the conventional systems. It leads to a reduction in the operational cost, comparing with systems using only mechanical refrigeration. Evaporative cooling operates using induced processes of heat and mass transfer, where water and air are the working fluids. It consists in water evaporation, induced by the passage of an air flow, thus decreasing the air temperature. This paper presents the basic principles of the evaporative cooling process for human thermal comfort, the principles of operation for the direct evaporative cooling system and the mathematical development of the equations of thermal exchanges, allowing the determination of the effectiveness of saturation. It also presents some results of experimental tests in a direct evaporative cooler that take place in the Air Conditioning Laboratory at the University of Taubaté Mechanical Engineering Department, and the experimental results are used to determinate the convective heat transfer coefficient and to compare with the mathematical model.


2021 ◽  
Vol 2069 (1) ◽  
pp. 012123
Author(s):  
A Tejero-González ◽  
F Nocera ◽  
V Costanzo ◽  
E Velasco-Gómez

Abstract Direct evaporative cooling is widely known to be an energy efficient air-conditioning option for arid and semi-arid climates. However, care must be taken on humidity ranges achieved indoors. Existing literature presents several options for integrating evaporative cooling within buildings for passive cooling applications. This work aims at expanding the current knowledge by focusing on the use of water-filled hollow bricks to implement evaporative cooling of air in contact with the brick’s surfaces. A prototype is built and experimentally characterized under controlled air velocity, air temperature and relative humidity conditions. Results on the psychrometric conditions achieved under different geometric arrangements (i.e., with one, two or three rows of four bricks each) are presented and discussed. Insights on likely building integration of the system for passive cooling purposes in farms and agriculture applications are eventually given.


2012 ◽  
Vol 608-609 ◽  
pp. 1198-1203
Author(s):  
Min Lei Chen ◽  
Xiao Long Liu ◽  
Eric Hu

Invention and the widely use of air conditioning has improved people’s working and living conditions. However, it also consumes significant amount of energy, accounting for over 40% of total energy used in the buildings. Indirect evaporative cooling (IEC) is a relatively new kind of air conditioning mechanism developed. It is not only uses less energy comparing with traditional air conditioning, but also overcomes the weaknesses of a direct evaporative cooling (DEC) system. The weaknesses of DEC include humidifying the supply air and minimum temperature of supply air is not lower than wet bulb temperature.


Author(s):  
Azridjal Aziz ◽  
Muhammad Rif’at Syahnan ◽  
Afdhal Kurniawan Mainil ◽  
Rahmat Iman Mainil

Split air conditioning systems produce reasonable amount of condensate which is usually not utilized and thrown away to the environment. On the other hand, it consumes a lot of energy during operation. The aim of this study is to investigate the improvement of air conditioning systems performance utilizing condensate. A direct evaporative cooling using condensate is incorporated on a 0.74 ton-cooling capacity of split air conditioning to decrease the air temperature before entering the condenser. Performances of the split air conditioning with and without direct evaporative cooling are compared and presented in this paper. The results show that the use of direct evaporative cooling using condensate into the air before passing through the condenser reduces the compressor discharge pressure. The decrease of the condenser pressure led to 4.7% and 7% reduction of power consumption for air conditioner without cooling load and air conditioner with 2000 W cooling load, respectively. The cooling effect and coefficient of performance (COP) increase with the decrease of compressor power. The use of direct evaporative cooling with condensate into the air before entering the condensing system can enhance the system performance and protect the environment.


2013 ◽  
Vol 389 ◽  
pp. 1085-1088 ◽  
Author(s):  
Jian Zhang

t focuses on the test and analysis of running conditions for the air conditioner and the functional segments at all levels in this paper, backed by the direct evaporative cooling air conditioning units experiment table. Analyze the influence of inlet air dry ball temperature and relative humidity to air conditioner cooling capacity and cooling efficiency, which has certain guiding significance to improve the direct evaporative cooling air conditioner performance.


The function of air conditioning systems has seen impressive development over the most recent couple of decades everywhere throughout the world, particularly in commercial buildings in ensuring the occupant thermal comfort. All the same, it is followed to have bad effects on the earth as well as increased power consumption in buildings. Hence, there has been extensive research to recognize options, in contrast to conventional vapour compression air conditioning systems. This account intends to review the ongoing improvements concerning evaporative cooling advancements that might give adequate cooling comfort, reduce environmental impact and lower energy consumption in buildings. Researches have done as on date in evaporative cooling systems centre predominantly around mainly on drawing down the dry bulb temperature of the incoming air. The theoretical efficiency of 100% can be achieved when the room dry bulb temperature is equal to the wet-bulb temperature of the outside atmospheric air. A wide literature review has been carried out and mapped out the best evaporative cooling systems. The review covers direct evaporative cooling, indirect evaporative cooling, and combined direct-indirect cooling systems.


2014 ◽  
Vol 472 ◽  
pp. 231-236
Author(s):  
Fan Kun ◽  
Huang Xiang

Introduced a communication equipment room in Xi'an transition season application tubular I/DEC (Indirect and Direct Evaporative Cooling) projects. The analysis the several modes optimized air handling units throughout the year. Finally, according to the operation of the evaporative cooling air conditioning system in the transitional seasons concluded.


2003 ◽  
Vol 2 (2) ◽  
pp. 30 ◽  
Author(s):  
J. R. Camargo ◽  
C. D. Ebinuma ◽  
S. Cardoso

Air conditioning systems are responsible for increasing men's work efficiency as well for his comfort, mainly in the warm periods of the year. Currently, the most used system is the mechanical vapor compression system. However, in many cases, evaporative cooling system can be an economical alternative to replace the conventional system, under several conditions, or as a pre-cooler in the conventional systems. It leads to a reduction in the operational cost, comparing with systems using only mechanical refrigeration. Evaporative cooling operates using induced processes of heat and mass transfer, where water and air are the working fluids. It consists in water evaporation, induced by the passage of an air flow, thus decreasing the air temperature. This paper presents the basic principles of the evaporative cooling process for human thermal comfort, the principles of operation for the direct evaporative cooling system and the mathematical development of the equations of thermal exchanges, allowing the determination of the effectiveness of saturation. It also presents some results of experimental tests in a direct evaporative cooler that take place in the Air Conditioning Laboratory at the University of Taubaté Mechanical Engineering Department, and the experimental results are used to determinate the convective heat transfer coefficient and to compare with the mathematical model.


Sign in / Sign up

Export Citation Format

Share Document