Latex covering of Palmaz stents and its effect on stent expansion

2005 ◽  
pp. 19-25
1996 ◽  
Vol 166 (4) ◽  
pp. 996-997 ◽  
Author(s):  
C E Ray ◽  
J A Kaufman ◽  
A C Waltman ◽  
W M Abbott

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Saurabhi Samant ◽  
Wei Wu ◽  
Shijia Zhao ◽  
Behram Khan ◽  
Mohammadali Sharzehee ◽  
...  

AbstractLeft main (LM) coronary artery bifurcation stenting is a challenging topic due to the distinct anatomy and wall structure of LM. In this work, we investigated computationally and experimentally the mechanical performance of a novel everolimus-eluting stent (SYNERGY MEGATRON) purpose-built for interventions to large proximal coronary segments, including LM. MEGATRON stent has been purposefully designed to sustain its structural integrity at higher expansion diameters and to provide optimal lumen coverage. Four patient-specific LM geometries were 3D reconstructed and stented computationally with finite element analysis in a well-validated computational stent simulation platform under different homogeneous and heterogeneous plaque conditions. Four different everolimus-eluting stent designs (9-peak prototype MEGATRON, 10-peak prototype MEGATRON, 12-peak MEGATRON, and SYNERGY) were deployed computationally in all bifurcation geometries at three different diameters (i.e., 3.5, 4.5, and 5.0 mm). The stent designs were also expanded experimentally from 3.5 to 5.0 mm (blind analysis). Stent morphometric and biomechanical indices were calculated in the computational and experimental studies. In the computational studies the 12-peak MEGATRON exhibited significantly greater expansion, better scaffolding, smaller vessel prolapse, and greater radial strength (expressed as normalized hoop force) than the 9-peak MEGATRON, 10-peak MEGATRON, or SYNERGY (p < 0.05). Larger stent expansion diameters had significantly better radial strength and worse scaffolding than smaller stent diameters (p < 0.001). Computational stenting showed comparable scaffolding and radial strength with experimental stenting. 12-peak MEGATRON exhibited better mechanical performance than the 9-peak MEGATRON, 10-peak MEGATRON, or SYNERGY. Patient-specific computational LM stenting simulations can accurately reproduce experimental stent testing, providing an attractive framework for cost- and time-effective stent research and development.


Author(s):  
Shana Tehrani ◽  
Sudhir Rathore ◽  
Vinod Achan

Abstract Background Management of heavily calcified coronary arteries is still a major challenge in interventional cardiology. Inadequate stent expansion in calcific lesions is the single most important predictor of stent thrombosis and in-stent restenosis. Rotational atherectomy (RA) is an important tool to modify the calcium burden but is associated with limitations and requires specific skills. Intravascular lithotripsy (IVL) is a novel technique to treat calcified stenotic lesions and has been proposed as an alternative to RA with promising results. Case summary We report a case of a patient with severely calcified right coronary artery stenosis successfully treated with combination of RA and IVL. Discussion In this case, we demonstrate that the RA and IVL are complementary strategies, not sufficient on their own and not alternative to each other.


2020 ◽  
Vol 20 (06) ◽  
pp. 2050039
Author(s):  
NISANTHKUMAR PANNEERSELVAM ◽  
SREEKUMAR MUTHUSWAMY

Deploying a stent to restore blood flow in the coronary artery is very complicated, as its internal diameter is smaller than 3[Formula: see text]mm. It has already been proven that mechanical stresses induced on stent and artery during deployment make the placement of stent very difficult, besides the development of complications due to artery damage. Various stent designs have already been developed, especially in the metallic category. Still, there are possibilities for developing new stent designs and patterns to overcome the complexities of the existing models. Also, the technology of metallic stents can be carried forward towards the development of bioresorbable polymeric stents. In this work, three new stent cell designs (curvature, diamond, and oval) have been proposed to obtain better performance and life. The finite element method is utilized to explore the mechanical behavior of stent expansion and determine the biomechanical stresses imposed on the stent and artery during the stenting procedure. The results obtained have been compared with the available literature and found that the curvature cell design develops lower stresses and, hence, be suitable for better performance and life.


2016 ◽  
Vol 9 (4) ◽  
pp. S12
Author(s):  
Mohamed Laimoud ◽  
Yasser Nassar ◽  
Akram Abdelbarre ◽  
Walid Omar ◽  
Helmy Elghawaby

2003 ◽  
Vol 26 (2) ◽  
pp. 158-167 ◽  
Author(s):  
Scott C. Goodwin ◽  
Hyo-Chun Yoon ◽  
Gary Chen ◽  
Peter Abdel-Sayed ◽  
Mary M. Costantino ◽  
...  