Development of a miniaturized Salmonella typhimurium reversion test with kinetic data acquisition

Author(s):  
H. Ehrlichmann ◽  
B. Mahn ◽  
W. Dott ◽  
A. Eisentraeger
2020 ◽  
Vol 10 (21) ◽  
pp. 7331-7343
Author(s):  
Paul Hazemann ◽  
Dominique Decottignies ◽  
Sylvie Maury ◽  
Séverine Humbert ◽  
Adrien Berliet ◽  
...  

The emergence of high-throughput experimentation gives new opportunities for accurate and rapid data acquisition for a wide variety of chemical reactions in different fields of application such as hydrocracking, isomerization and syngas conversion.


2013 ◽  
Vol 765-767 ◽  
pp. 2595-2599
Author(s):  
Lei Dang ◽  
Zhen Li ◽  
Xiao Hua Sun ◽  
Hui Ying Yang

The sensor technology is applied to the discus sports, which can be called digital discus, a real-time data acquisition of the moving discus information can be easily gained. The system uses statistical analysis and data mining to do analysis with these collected data. It's solved the problem on getting the accurate kinetic data and kinematics data of the moving discus for the sports like discus, and proved significant data for study athlete's technical movement and achievement.


Author(s):  
Mateus Corrêa Silveira ◽  
Francielle Marques Pivetta ◽  
Carlos Bolli Mota

Introdução: A análise da marcha permite avaliar parâmetros da marcha de diferentes populações. Frequentemente essas variáveis estão associadas aos eventos que determinam as fases da marcha: o toque do calcanhar e a saída do pé. Os dados fornecidos por plataformas de força são considerados ideais para detectar o instante correto desses eventos, mas o efeito de diferentes frequências de aquisição adotadas para determiná-los não é muito conhecido.Objetivo: Determinar o efeito de diferentes frequências de aquisição de plataformas de força para detectar os eventos da marcha.Métodos: Um homem adulto caminhou na sua velocidade preferida. Os dados cinéticos foram obtidos por duas plataformas de força com frequências de aquisição em 1000 Hz. Após as coletas, os dados foram amostrados novamente em 500 Hz, 250 Hz, 200 Hz e 100 Hz, removendo amostras a partir eliminação de múltiplos. Dois limiares de força foram adotados na detecção dos dois eventos: 5 Newtons e 20 Newtons.Resultados: Os resultados mostraram diferenças entre todas as frequências de aquisição, exceto 250 Hz e 200 Hz, para o toque do calcanhar e a saída do pé em ambos os limiares de força. Um atraso na detecção dos eventos foi observado à medida que a frequência de aquisição diminuía.Conclusão: Maiores frequências de aquisição das plataformas são mais apropriadas para a detecção dos eventos da marcha. Os dados cinéticos podem ser mais precisos para definir os tempos de apoio e balanço do que dados cinemáticos.Determination of Gait Events with Different Force Plate Acquisition FrequenciesIntroduction: Gait analysis allows assessing walking parameters of different populations. Frequently, these variables are associated with events which determine the phases of the gait: the heel strike and the foot off. Data provided by force plates are considered a good mean to detect precise event times, however the effect of different data acquisition frequencies adopted are still unknown.Objective: To determine the effect of different acquisition frequencies of force plates on gait events detection.Introduction: Gait analysis allows assessing walking parameters of different populations. Frequently, these variables are associated with events which determine the phases of the gait: the heel strike and the foot off. Data provided by force plates are considered a good mean to detect precise event times, however the effect of different data acquisition frequencies adopted are still unknown.Methods: An adult man walked in his preferred gait speed. Kinetic data were obtained by two force plates with acquisition frequency of 1000 Hz. After data collection, the data was resampled again in 500 Hz, 250 Hz, 200 Hz e 100 Hz, removing samples by eliminating multiples. Two force thresholds were adopted to detect gait events: 5 Newtons e 20 Newtons.Results: Differences between all frequencies of acquisition were shown, except between 250 Hz and 200 Hz, for both heel strike and foot off and force thresholds. A detection delay is observed as the acquisition frequency decrease.Conclusion: Higher force plates acquisition frequencies are better to detect gait events Kinect data can be more accurate to define stance and swing times than kinematic data.


Sign in / Sign up

Export Citation Format

Share Document