Development and Validation of Multiwavelength Algorithms for in Vivo Near Infrared Spectroscopy

1989 ◽  
pp. 69-82 ◽  
Author(s):  
Claude A. Piantadosi ◽  
Benjamin J. Comfort
2019 ◽  
Vol 9 (11) ◽  
pp. 2366 ◽  
Author(s):  
Laura Di Sieno ◽  
Alberto Dalla Mora ◽  
Alessandro Torricelli ◽  
Lorenzo Spinelli ◽  
Rebecca Re ◽  
...  

In this paper, a time-domain fast gated near-infrared spectroscopy system is presented. The system is composed of a fiber-based laser providing two pulsed sources and two fast gated detectors. The system is characterized on phantoms and was tested in vivo, showing how the gating approach can improve the contrast and contrast-to-noise-ratio for detection of absorption perturbation inside a diffusive medium, regardless of source-detector separation.


2008 ◽  
Vol 13 (4) ◽  
pp. 044003 ◽  
Author(s):  
Lijuan Dai ◽  
Zhiyu Qian ◽  
Kuanzheng Li ◽  
Tianming Yang ◽  
Huinan Wang

1994 ◽  
Vol 77 (1) ◽  
pp. 5-10 ◽  
Author(s):  
K. K. McCully ◽  
S. Iotti ◽  
K. Kendrick ◽  
Z. Wang ◽  
J. D. Posner ◽  
...  

Simultaneous measurements of phosphocreatine (PCr) and oxyhemoglobin (HbO2) saturation were made during recovery from exercise in calf muscles of five male subjects. PCr was measured using magnetic resonance spectroscopy in a 2.0-T 78-cm-bore magnet with a 9-cm-diam surface coil. Relative HbO2 saturation was measured as the difference in absorption of 750- and 850-nm light with use of near-infrared spectroscopy. The light source and detectors were 3 cm apart. Exercise consisted of isokinetic plantar flexion in a supine position. Two 5-min submaximal protocols were performed with PCr depletion to 60% of resting values and with pH values of > 7.0. Then two 1-min protocols of rapid plantar flexion were performed to deplete PCr values to 5–20% of resting values with pH values of < 6.8. Areas of PCr peaks (every 8 s) and HbO2 saturation (every 1 s) were fit to a monoexponential function, and a time constant was calculated. The PCr time constant was larger after maximal exercise (68.3 +/- 10.5 s) than after submaximal exercise (36.0 +/- 6.5 s), which is consistent with the effects of low pH on PCr recovery. HbO2 resaturation approximated submaximal PCr recovery and was not different between maximal (29.4 +/- 5.5 s) and submaximal (27.6 +/- 6.0 s) exercise. We conclude that magnetic resonance spectroscopy measurements of PCr recovery and near-infrared spectroscopy measurements of recovery of HbO2 saturation provide similar information as long as muscle pH remains near 7.0.


Author(s):  
Sachiko Kessoku ◽  
Katsuhiko Maruo ◽  
Shinpei Okawa ◽  
Kazuto Masamoto ◽  
Yukio Yamada

Various non-invasive glucose monitoring methods using near-infrared spectroscopy have been investigated although no method has been successful so far. Our previous study has proposed a new promising method utilizing numerically generated absorbance spectra instead of the experimentally acquired absorbance spectra. The method suggests that the correct estimation of the optical properties is very important for numerically generating the absorbance spectra. The purpose of this study is to measure the change in the optical properties of the skin with the change in the blood glucose level in vivo. By measuring the reflectances of light incident on the skin surface at two distances from the incident point, the optical properties of the skin can be estimated. The estimation is a kind of the inverse problem based on the simulation of light propagation in the skin. Phantom experiments have verified the method and in vivo experiments are to be performed.