On-Line Quality Control in Clinical Chemistry

Author(s):  
Roy Baker ◽  
John Upham ◽  
Joseph Schroeder ◽  
W. B. Stewart
2020 ◽  
Vol 0 (0) ◽  
Author(s):  
Mingyang Wang ◽  
Liang Ming

AbstractObjectivesThe pre- and post-analytical processes have been discussed both in total laboratory system (TLA) and modular automation (MA). The analytical process, especially reagent-related factors influences on the integrated clinical chemistry analyzer, demonstrates a significant effect on clinical chemistry analyzer. Modular analyzer reagent-loading mode influences two mainly factors, testing turnaround time (tTAT) and the cost. Furthermore, how to definite the different reagent loading manners and verify the best reagent loading manner is big challenge.MethodsWe focus on tTAT, and study how the reagent-related factors effect TAT by simulations and verifications. Parameters were simulated by cobas 8000 workflow simulator for reagent-loading manner with at least three positions (Pattern 1), the module-parallel reagent-loading manner (Pattern 2) and the single-position loading mode (Pattern 3).ResultstTAT, reagent on-line time, quality control (QC) cost and performance verification times all declined by 43%. Tuesday effect solved the repetitive problem for verification. Pattern 2 shows optimal performance in Tuesday effect-based verification.ConclusionsThe optimization of reagent-loading manner saved much workforce, and reduced the QC cost.


1995 ◽  
pp. 37-57 ◽  
Author(s):  
Frank W. Henrikson
Keyword(s):  

1992 ◽  
Vol 97 (5) ◽  
pp. 645-651
Author(s):  
Veli Kairisto ◽  
Timo Kouri ◽  
Allan Rajamäki ◽  
Arja Virtanen ◽  
Esa Uusipaikka ◽  
...  

2007 ◽  
Vol 26 (3) ◽  
pp. 245-247
Author(s):  
Petros Karkalousos

The Schemes of External Quality Control in Laboratory Medicine in the Balkans There are many differences between the national External Quality Control Schemes all around Europe, but the most important ones are certainly those between the countries of the Balkan region. These differences are due to these countries' different political and financial development, as well as to their tradition and the development of clinical chemistry science in each one. Therefore, there are Balkan countries with very developed EQAS and others where there is no such a scheme. Undoubtedly, the scientific community in these countries wants to develop EQAS despite of the financial and other difficulties.


1972 ◽  
Vol 18 (3) ◽  
pp. 250-257 ◽  
Author(s):  
J H Riddick ◽  
Roger Flora ◽  
Quentin L Van Meter

Abstract A system of quality-control data analysis by computer is described, in which two-way analysis of variance is used for partitioning sources of laboratory error into day-to-day, within-day, betweenpools and additivity variation. The partition for additivity is described in detail as to its advantages and applications. In addition, control charts based on two-way analysis of variance computations are prepared each month by computer. This computer program is designed to operate with the IBM 1800 or 1130 computers or any computer with a Fortran IV compiler. Examples are presented of use of the control charts and of tables of analysis of variance.


1977 ◽  
Vol 74 (3) ◽  
pp. 191-201 ◽  
Author(s):  
A.P. Jansen ◽  
E.J. Van Kampen ◽  
B. Leijnse ◽  
C.A.M. Meijers ◽  
P.J.J. Van Munster

Sign in / Sign up

Export Citation Format

Share Document