An Upper Limit to the Atomic Carbon Abundance in the Orion Plateau

Author(s):  
C. A. Beichman ◽  
T. G. Phillips ◽  
H. A. Wootten ◽  
M. Frerking
2011 ◽  
Vol 743 (2) ◽  
pp. L39 ◽  
Author(s):  
Kunihiko Tanaka ◽  
Tomoharu Oka ◽  
Shinji Matsumura ◽  
Makoto Nagai ◽  
Kazuhisa Kamegai

2021 ◽  
Vol 504 (2) ◽  
pp. 2360-2380
Author(s):  
Qian Jiao ◽  
Yu Gao ◽  
Yinghe Zhao

ABSTRACT Using the atomic carbon [C i] ($^{3} \rm P_{1} \rightarrow {\rm ^3 P}_{0}$) and [C i] ($^{3} \rm P_{2} \rightarrow {\rm ^3 P}_{1}$) emission {hereafter [C i] (1 − 0) and [C i] (2 − 1), respectively} maps observed with the Herschel Space Observatory, and CO (1 − 0), H i, infrared and submm maps from literatures, we estimate the [C i]-to-H2 and CO-to-H2 conversion factors of α[C i](1 − 0), α[C i](2 − 1), and αCO at a linear resolution $\sim 1\,$kpc scale for six nearby galaxies of M 51, M 83, NGC 3627, NGC 4736, NGC 5055, and NGC 6946. This is perhaps the first effort, to our knowledge, in calibrating both [C i]-to-H2 conversion factors across the spiral disks at spatially resolved $\sim 1\,$kpc scale though such studies have been discussed globally in galaxies near and far. In order to derive the conversion factors and achieve these calibrations, we adopt three different dust-to-gas ratio (DGR) assumptions that scale approximately with metallicity taken from precursory results. We find that for all DGR assumptions, the α[C i](1 − 0), α[C i](2 − 1), and αCO are mostly flat with galactocentric radii, whereas both α[C i](2 − 1) and αCO show decrease in the inner regions of galaxies. And the central αCO and α[C i](2 − 1) values are on average ∼2.2 and 1.8 times lower than its galaxy averages. The obtained carbon abundances from different DGR assumptions show flat profiles with galactocentric radii, and the average carbon abundance of the galaxies is comparable to the usually adopted value of 3 × 10−5. We find that both metallicity and infrared luminosity correlate moderately with the αCO, whereas only weakly with either the α[C i](1 − 0) or carbon abundance, and not at all with the α[C i](2 − 1).


2008 ◽  
Vol 31 ◽  
pp. 177-178
Author(s):  
M. Hitschfeld ◽  
M. Aravena ◽  
C. Kramer ◽  
F. Bertoldi ◽  
J. Stutzki ◽  
...  

2015 ◽  
Vol 54 (03) ◽  
pp. 106-111 ◽  
Author(s):  
S. L. Andersen ◽  
P. Laurberg

SummaryThyroid hormones are essential development factors and maternal thyroid dysfunction may cause pregnancy complications and diseases in the fetus/child. In the present review we discuss new data on the incidence of Graves'-Basedow disease (GBD) in and around pregnancy, and how hyperthyroidism may affect the risk of spontaneous abortion and stillbirth.A special concern in pregnant women is the potential side effects from the use of antithyroid drugs (ATDs). One type of side effects is the allergic/toxic reactions to the drugs, which seem to be similar in and outside pregnancy, and another is that ATDs tend to over treat the fetus when the mother with GBD is made euthyroid. To avoid fetal hypothyroidism, the lowest possible ATD dose should be used to keep maternal thyroid function at the upper limit of normality with low serum TSH. Birth defects after the use of methimazole (MMI) (or its prodrug carbimazole) have been considered to be very rare, and no risk has previously been associated with the use of propylthiouracil (PTU). However, a recent Danish national study found that 1/30 of children exposed to MMI in early pregnancy had birth defects associated with this, and many defects were severe. PTU exposure was associated with defects in 1/40, and these defects were less severe. Proposals are given on how to reduce the risk of ATD associated birth defects.


1985 ◽  
Vol 24 (03) ◽  
pp. 107-110
Author(s):  
M. Pääkkönen ◽  
S. Aukee ◽  
K. Korhonen ◽  
A. Pääkkönen ◽  
E. Länsimies ◽  
...  

SummaryIn this work the duodenogastric reflux was quantified as the amount of radioactivity entering the stomach after an i.v. administration of 99mmTc-HIDA in ulcer patients and in patients who had undergone BI gastrectomy. The results were compared with visual evidence of gastric activity in the gamma camera images and biochemical determination of gastric bile reflux. The method is useful in quantifying the reflux if the activity is above the background activity. It allows the determination of an upper limit for the reflux when the reflux is evident visually. Only two or three images are needed for the quantitation. No correlation was found between biochemical measurement of fasting bile reflux in the stomach and radioisotopic quantification.


2013 ◽  
Vol 41 (01) ◽  
pp. 31-36
Author(s):  
E. Kienzle ◽  
N. Becker

ZusammenfassungIm Rahmen einer Eliminationsdiät wird regelmäßig Pferdefleisch eingesetzt. Aus Gründen der Praktikabilität verwenden Tierbesitzer häufig kommerziell erhältliches Pferdefleisch aus der Dose. Aufgrund eines Berichts von Zervikalspondylosen bei einer auf Futtermittel allergischen Katze erfolgte eine Analyse verschiedener auf Pferdefleisch basierender Produkte hinsichtlich des Vitamin-AGehalts.In 14 Pferdefleischerzeugnissen wurde der Vitamin-A-Gehalt (Retinol) analysiert. Der Gehalt an umsetzbarer Energie wurde mithilfe von Schätzformeln auf Basis der Deklaration berechnet.In Produkten mit deklarierten Anteilen von Leber, Innereien oder tierischen Nebenprodukten konnten zum Teil erhebliche Vitamin-A-Gehalte festgestellt werden. Bei alleiniger Verfütterung eines dieser Produkte (Deckung des durchschnittlichen Energiebedarfs) würde die Vitamin-A-Versorgung nur knapp unter dem Safe Upper Limit der Katze sowie oberhalb des Safe Upper Limits beim Hund liegen.Bei All-Meat-Produkten sollte nicht nur die Deklaration, sondern auch der Inhalt näher betrachtet werden, um einen Hinweis auf eventuell hohe Leberanteile zu erhalten.Aufgrund der Ergebnisse ist eine exzessive Vitamin-A-Aufnahme bei langfristiger Verfütterung von Pferdefleischprodukten mit hohen Leberanteilen nicht auszuschließen.


1993 ◽  
Vol 69 (05) ◽  
pp. 430-435 ◽  
Author(s):  
Colin Longstaff ◽  
Man-Yu Wong ◽  
Patrick J Gaffney

SummaryAn international collaborative study has been carried out to investigate the reproducibility of hirudin assays in 13 laboratories using four recombinant hirudins and one natural, sulphated product. A simple assay procedure was proposed involving the titration of α-thrombin with inhibitor and measurement of residual activity using a chromogenic substrate. A standard α-thrombin preparation was supplied to ensure that this reagent was of uniform quality throughout the study. The method appeared to present no difficulties and laboratories reported similar potencies for the 5 hirudin samples, in line with expected values. This gave 200–222 Thrombin Inhibitory Units/ampoule (TIU/ampoule) of lyophilised hirudin, with geometric coefficient of variation (gcv) values ranging from 10.15–15.97%. This corresponds to specific activities of approximately 14,300–15,900 TIU/mg protein. This is close to the upper limit of previously reported values of specific activity. We conclude that the precision of this determination compared with the wider range of values in the literature (8,000–16,000 thrombin inhibitory units [TIU]/mg) results from the use of good quality standard α-thrombin by all laboratories. This study has important implications for hirudin standardisation.


Sign in / Sign up

Export Citation Format

Share Document