Shear Behavior of Steel Reinforced Ultra High Performance Concrete Members with Hybrid Fibers

Author(s):  
M. Bermudez ◽  
C. C. Hung
PCI Journal ◽  
2020 ◽  
Vol 65 (6) ◽  
pp. 35-61
Author(s):  
Chungwook Sim ◽  
Maher Tadros ◽  
David Gee ◽  
Micheal Asaad

Ultra-high-performance concrete (UHPC) is a special concrete mixture with outstanding mechanical and durability characteristics. It is a mixture of portland cement, supplementary cementitious materials, sand, and high-strength, high-aspect-ratio microfibers. In this paper, the authors propose flexural design guidelines for precast, prestressed concrete members made with concrete mixtures developed by precasters to meet minimum specific characteristics qualifying it to be called PCI-UHPC. Minimum specified cylinder strength is 10 ksi (69 MPa) at prestress release and 18 ksi (124 MPa) at the time the member is placed in service, typically 28 days. Minimum flexural cracking and tensile strengths of 1.5 and 2 ksi (10 and 14 MPa), respectively, according to ASTM C1609 testing specifications are required. In addition, strain-hardening and ductility requirements are specified. Tensile properties are shown to be more important for structural optimization than cylinder strength. Both building and bridge products are considered because the paper is focused on capacity rather than demand. Both service limit state and strength limit state are covered. When the contribution of fibers to capacity should be included and when they may be ignored is shown. It is further shown that the traditional equivalent rectangular stress block in compression can still be used to produce satisfactory results in prestressed concrete members. A spreadsheet workbook is offered online as a design tool. It is valid for multilayers of concrete of different strengths, rows of reinforcing bars of different grades, and prestressing strands. It produces moment-curvature diagrams and flexural capacity at ultimate strain. A fully worked-out example of a 250 ft (76.2 m) span decked I-beam of optimized shape is given.


2017 ◽  
Vol 19 (1) ◽  
pp. 305-317 ◽  
Author(s):  
Sifatullah Bahij ◽  
Saheed K. Adekunle ◽  
Mohammed Al-Osta ◽  
Shamsad Ahmad ◽  
Salah U. Al-Dulaijan ◽  
...  

2020 ◽  
Vol 23 (16) ◽  
pp. 3401-3414
Author(s):  
Yuqing Hu ◽  
Huiguang Yin ◽  
Xiaomeng Ding ◽  
Shuai Li ◽  
JQ Wang

In this article, the static shear behavior of large-headed studs embedded in ultra-high-performance concrete was investigated by push-out test and numerical analysis. A total of nine push-out specimens with single and grouped studs embedded in ultra-high-performance concrete and normal strength concrete slabs were tested. In the testing process, only shank failure appeared without cracks occurring on the surface of ultra-high-performance concrete slab when the steel–ultra-high-performance concrete specimens reached ultimate shear capacity. The shear capacity of specimens with large studs embedded in ultra-high-performance concrete slab increased by 10.6% compared those in normal concrete, and the current design codes such as Eurocode4, AASHTO LFRD 2014, and GB50017-2003 all underestimate the shear capacity of such kind of steel–ultra-high-performance concrete composite structures according to experimental results. Numerical models were established using ABAQUS with introducing damage plasticity material model. The influence of stud diameter, concrete strength, thickness of clear cover, and spacing of studs on the static shear behavior was thoroughly investigated via parametric analysis. Based on the experimental and numerical analysis, the existence of wedge block and the decrease of axis force are beneficial for improving the shear capacity of stud shear connectors.


2009 ◽  
Vol 79-82 ◽  
pp. 2047-2050 ◽  
Author(s):  
Min Gin Lee ◽  
Yi Shuo Huang

There are some reinforced concrete structures exposed to severe environmental conditions might require maintenance or strengthening. Many of these severe circumstances are the result of extreme climate conditions such as low temperature, freeze–thaw action, fire attack, and exposure to deicing salts. Because of this, the environmental durability of both the repair materials and methods used in rehabilitation applications are of utmost importance. A small fire can reach 250°C, while a common blaze can easily produce temperatures of around 800°C. In major conflagrations the temperature can even reach 1100°C. At this level, the heat affects most materials, provoking the spontaneous combustion of some of them and affecting the resistance of others. However, very little research has been performed in evaluating the environmental durability of strengthening materials for concrete members. Very little work has been done on the effects of freeze–thaw cycling on bonding and repair materials. In this study, ultra high performance concrete (UHPC) was used to investigate the effect of strengthening concrete members by fire-damage test or freeze-thaw test. The results show that the mechanical properties of UHPC possess high strength, toughness, and freeze-thaw resistance. The CFRP (carbon fiber reinforced plates) wrapping specimens exposed at 300 °C showed totally failure with the deterioration of the adhesive. The UHPC with bonding 10 mm thickness specimens exposed at 400 °C and duration of 1 hour still in good shape. The UHPC with 1-cm or 2-cm thickness on strengthening concrete members could be obtained specific retrofit effects. The performance of UHPC specimens is better than those of CFRP wrapping specimens during high temperature exposure. The results of slant shear tests show that the bond strength of PC/PC, UHPC/PC and UHPC/UHPC decreased significantly after 600 freeze–thaw cycles or high temperature exposure.


Sign in / Sign up

Export Citation Format

Share Document