Dose-response effects and time course of effects of inhaled fenoterol on respiratory mechanics and arterial oxygen tension in mechanically ventilated patients with chronic airflow obstruction

1990 ◽  
Vol 16 (2) ◽  
pp. 108-114 ◽  
Author(s):  
M. Bernasconi ◽  
R. Brandolese ◽  
R. Poggi ◽  
E. Manzin ◽  
A. Rossi
2011 ◽  
Vol 38 (1) ◽  
pp. 91-98 ◽  
Author(s):  
Glenn Eastwood ◽  
Rinaldo Bellomo ◽  
Michael Bailey ◽  
Gopal Taori ◽  
David Pilcher ◽  
...  

2018 ◽  
Vol 62 (10) ◽  
pp. 1443-1451 ◽  
Author(s):  
O. L. Schjørring ◽  
A. P. Toft‐Petersen ◽  
K. H. Kusk ◽  
P. Mouncey ◽  
E. E. Sørensen ◽  
...  

1998 ◽  
Vol 74 (4) ◽  
pp. 275-83
Author(s):  
Antônio C. P. Ferreira ◽  
Benjamin I. Kopelman ◽  
Werther Brunow de Carvalho ◽  
Jorge Bonassa

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Shinshu Katayama ◽  
Jun Shima ◽  
Ken Tonai ◽  
Kansuke Koyama ◽  
Shin Nunomiya

AbstractRecently, maintaining a certain oxygen saturation measured by pulse oximetry (SpO2) range in mechanically ventilated patients was recommended; attaching the INTELLiVENT-ASV to ventilators might be beneficial. We evaluated the SpO2 measurement accuracy of a Nihon Kohden and a Masimo monitor compared to actual arterial oxygen saturation (SaO2). SpO2 was simultaneously measured by a Nihon Kohden and Masimo monitor in patients consecutively admitted to a general intensive care unit and mechanically ventilated. Bland–Altman plots were used to compare measured SpO2 with actual SaO2. One hundred mechanically ventilated patients and 1497 arterial blood gas results were reviewed. Mean SaO2 values, Nihon Kohden SpO2 measurements, and Masimo SpO2 measurements were 95.7%, 96.4%, and 96.9%, respectively. The Nihon Kohden SpO2 measurements were less biased than Masimo measurements; their precision was not significantly different. Nihon Kohden and Masimo SpO2 measurements were not significantly different in the “SaO2 < 94%” group (P = 0.083). In the “94% ≤ SaO2 < 98%” and “SaO2 ≥ 98%” groups, there were significant differences between the Nihon Kohden and Masimo SpO2 measurements (P < 0.0001; P = 0.006; respectively). Therefore, when using automatically controlling oxygenation with INTELLiVENT-ASV in mechanically ventilated patients, the Nihon Kohden SpO2 sensor is preferable.Trial registration UMIN000027671. Registered 7 June 2017.


1985 ◽  
Vol 58 (6) ◽  
pp. 1849-1858 ◽  
Author(s):  
A. Rossi ◽  
S. B. Gottfried ◽  
B. D. Higgs ◽  
L. Zocchi ◽  
A. Grassino ◽  
...  

In 11 mechanically ventilated patients, respiratory mechanics were measured 1) during constant flow inflation and 2) following end-inflation airway occlusion, as proposed in model analysis (J. Appl. Physiol. 58: 1840–1848, 1985. During the latter part of inflation, the relationship between driving pressure and lung volume change was linear, allowing determination of static respiratory elastance (Ers) and resistance (RT). The latter represents in each patient the maximum resistance value that can obtain with the prevailing time constant inhomogeneity. Following occlusion, Ers and RT were also obtained along with RT (min) which represents a minimum, i.e., resistance value that would obtain in the absence of time constant inhomogeneity. A discrepancy between inflation and occlusion Ers and RT was found only in the three patients without positive end-expiratory pressure, and could be attributed to recruitment of lung units during inflation. In all instances Ers and RT were higher than normal. RT(min) was lower in all patients than the corresponding values of RT, indicating that resistance was frequency dependent due to time constant inequalities. Changes in inflation rate did not affect Ers, while RT increased with increasing flow.


Sign in / Sign up

Export Citation Format

Share Document