Mechanical and control issues for integration of an arm-hand robotic system

Author(s):  
Claudio Melchiorri ◽  
Gabriele Vassura
Keyword(s):  
Sensors ◽  
2021 ◽  
Vol 21 (4) ◽  
pp. 1537
Author(s):  
Florin Covaciu ◽  
Adrian Pisla ◽  
Anca-Elena Iordan

The traditional systems used in the physiotherapy rehabilitation process are evolving towards more advanced systems that use virtual reality (VR) environments so that the patient in the rehabilitation process can perform various exercises in an interactive way, thus improving the patient’s motivation and reducing the therapist’s work. The paper presents a VR simulator for an intelligent robotic system of physiotherapeutic rehabilitation of the ankle of a person who has had a stroke. This simulator can interact with a real human subject by attaching a sensor that contains a gyroscope and accelerometer to identify the position and acceleration of foot movement on three axes. An electromyography (EMG) sensor is also attached to the patient’s leg muscles to measure muscle activity because a patient who is in a worse condition has weaker muscle activity. The data collected from the sensors are taken by an intelligent module that uses machine learning to create new levels of exercise and control of the robotic rehabilitation structure of the virtual environment. Starting from these objectives, the virtual reality simulator created will have a low dependence on the therapist, this being the main improvement over other simulators already created for this purpose.


Author(s):  
C. Raoufi ◽  
A. A. Goldenberg ◽  
W. Kucharczyk ◽  
H. Hadian

In this paper, the inverse kinematic and control paradigm of a novel tele-robotic system for MRI-guided interventions for closed-bore MRI-guided brain biopsy is presented. Other candidate neurosurgical procedures enabled by this system would include thermal ablation, radiofrequency ablation, deep brain stimulators, and targeted drug delivery. The control architecture is also reported. The design paradigm is fundamentally based on a modular design configuration of the slave manipulator that is performing tasks inside MR scanner. The tele-robotic system is a master-slave system. The master manipulator consists of three units including: (i) the navigation module; (ii) the biopsy module; and (iii) the surgical arm. Navigation and biopsy modules were designed to undertake the alignment and advancement of the surgical needle respectively. The biopsy needle is held and advanced by the biopsy module. The biopsy module is attached to the navigation module. All three units are held by a surgical arm. The main challenge in the control of the biopsy needle using the proposed navigation module is to adjust a surgical tool from its initial position and orientation to a final position and orientation. In a typical brain biopsy operation, the desired task is to align the biopsy needle with a target knowing the positions of both the target in the patient’s skull and the entry point on the surface of the skull. In this paper, the mechanical design, control paradigms, and inverse kinematics model of the robot are reported.


2021 ◽  
Author(s):  
Ahmad Kourani ◽  
Naseem Daher

Abstract This work presents the nonlinear dynamical model and motion controller of a system consisting of an unmanned aerial vehicle (UAV) that is tethered to a floating buoy in the three-dimensional (3D) space. Detailed models of the UAV, buoy, and the coupled tethered system dynamics are presented in a marine environment that includes surface-water currents and oscillating gravity waves, in addition to wind gusts. This work extends the previously modeled planar (vertical) motion of this novel robotic system to allow its free motion in all three dimensions. Furthermore, a Directional Surge Velocity Control System (DSVCS) is hereby proposed to allow both the free movement of the UAV around the buoy when the cable is slack, and the manipulation of the buoy’s surge velocity when the cable is taut. Using a spherical coordinate system centered at the buoy, the control system commands the UAV to apply forces on the buoy at specific azimuth and elevation angles via the tether, which yields a more appropriate realization of the control problem as compared to the Cartesian coordinates where the traditional x- , y- , and z -coordinates do not intuitively describe the tether’s tension and orientation. The proposed robotic system and controller offer a new method of interaction and collaboration between UAVs and marine systems from a locomotion perspective. The system is validated in a virtual high-fidelity simulation environment, which was specifically developed for this purpose, while considering various settings and wave scenarios.


Author(s):  
Yuyang Lin ◽  
Yunlai Shi ◽  
Jun Zhang ◽  
Fugang Wang ◽  
Wenbo Wu ◽  
...  
Keyword(s):  

2011 ◽  
Vol 121-126 ◽  
pp. 3805-3809 ◽  
Author(s):  
Yong De Zhang ◽  
Ji Xiong Jiang

Archwire bending is one of the key components in orthodontic treatment. However, it is a very difficult work due to the high stiffness and superelasticity of orthodontic wire. The traditional way of acquiring the formed archwire curve is based on manual operation, which will randomly bring numerous errors caused by human factors. This paper proposes a novel robotic system to bend archwire into desired configuration. Structure and elements of robotic system for archwire bending was studied. Coordinate systems of robotic system were built up. Control points of end effector and control angle of each control point were planned. Preliminary orthodontic wire bending experimentation has been done using the robotic system. The experimental results verified the feasibility of the manufacture strategy of formed orthodontic wire fulfilled by robotic system for orthodontic wire bending.


Sign in / Sign up

Export Citation Format

Share Document