Added value of point shear-wave elastography in the diagnosis of acute cholecystitis

2016 ◽  
Vol 27 (4) ◽  
pp. 1517-1526 ◽  
Author(s):  
Ji Eun Kim ◽  
Dae Seob Choi ◽  
Kyungsoo Bae ◽  
Jae Min Cho ◽  
Chi Young Jeong ◽  
...  
2017 ◽  
pp. 20170676
Author(s):  
Amandine Crombé ◽  
Gabrielle Hurtevent-Labrot ◽  
Maryam Asad-Syed ◽  
Jean Palussière ◽  
Gaetan MacGrogan ◽  
...  

Radiology ◽  
2014 ◽  
Vol 273 (1) ◽  
pp. 61-69 ◽  
Author(s):  
Su Hyun Lee ◽  
Jung Min Chang ◽  
Won Hwa Kim ◽  
Min Sun Bae ◽  
Mirinae Seo ◽  
...  

2019 ◽  
Vol 92 (1097) ◽  
pp. 20180341 ◽  
Author(s):  
Hye Young Choi ◽  
Mirinae Seo ◽  
Yu-Mee Sohn ◽  
Ji Hye Hwang ◽  
Eun Jee Song ◽  
...  

2014 ◽  
Vol 83 (5) ◽  
pp. 773-777 ◽  
Author(s):  
Victor Ianculescu ◽  
Laura Maria Ciolovan ◽  
Ariane Dunant ◽  
Philippe Vielh ◽  
Chafika Mazouni ◽  
...  

2020 ◽  
Vol 39 (4) ◽  
pp. 384-393
Author(s):  
Ara Ko ◽  
Eun Sun Lee ◽  
Hyun Jeong Park ◽  
Sung Bin Park ◽  
Hee Sung Kim ◽  
...  

Author(s):  
Anders Batman Mjelle ◽  
Anesa Mulabecirovic ◽  
Roald Flesland Havre ◽  
Edda Jonina Olafsdottir ◽  
Odd Helge Gilja ◽  
...  

Abstract Purpose Liver elastography is increasingly being applied in screening for and follow-up of pediatric liver disease, and has been shown to correlate well with fibrosis staging through liver biopsy. Because time is of the essence when examining children, we wanted to evaluate if a reliable result can be achieved with fewer acquisitions. Materials and Methods 243 healthy children aged 4–17 years were examined after three hours of fasting. Participants were divided into four age groups: 4–7 years; 8–11 years; 12–14 years and 15–17 years. Both two-dimensional shear wave elastography (2D-SWE; GE Logiq E9) and point shear wave elastography (pSWE; Samsung RS80A with Prestige) were performed in all participants, while transient elastography (TE, Fibroscan) was performed in a subset of 87 children aged 8–17 years. Median liver stiffness measurement (LSM) values of 3, 4, 5, 6, 7, and 8 acquisitions were compared with the median value of 10 acquisitions (reference standard). Comparison was performed for all participants together as well as within every specific age group. We investigated both the intraclass correlation coefficient (ICC) with absolute agreement and all outliers more than 10 %, 20 % or ≥ 0.5 or 1.0 kPa from the median of 10 acquisitions. Results For all three systems there was no significant difference between three and ten acquisitions, with ICCs ≥ 0.97. All systems needed 4 acquisitions to achieve no LSM deviating ≥ 1.0 kPa of a median of ten. To achieve no LSM deviating ≥ 20 % of a median of ten acquisitions, pSWE and TE needed 4 acquisitions, while 2D-SWE required 6 acquisitions. Conclusion Our results contradict recommendations of 10 acquisitions for pSWE and TE and only 3 for 2D-SWE.


Sign in / Sign up

Export Citation Format

Share Document