Differentiation of regenerative nodule, dysplastic nodule, and small hepatocellular carcinoma in cirrhotic patients: a contrast-enhanced ultrasound–based multivariable model analysis

2020 ◽  
Vol 30 (9) ◽  
pp. 4741-4751
Author(s):  
Yu Duan ◽  
Xiaoyan Xie ◽  
Qian Li ◽  
Nathaniel Mercaldo ◽  
Anthony E. Samir ◽  
...  
2016 ◽  
Vol 12 (8) ◽  
pp. 274 ◽  
Author(s):  
Hongwei Shi ◽  
Huadong Deng ◽  
Jianming Lei ◽  
Yan Hu ◽  
Gang Li ◽  
...  

Author(s):  
Barbara Schellhaas ◽  
Thomas Bernatik ◽  
Wolfram Bohle ◽  
Fanny Borowitzka ◽  
Johannes Chang ◽  
...  

Abstract Background This prospective multicenter study funded by the DEGUM assesses the diagnostic accuracy of standardized contrast-enhanced ultrasound (CEUS) for the noninvasive diagnosis of hepatocellular carcinoma (HCC) in high-risk patients. Methods Patients at high risk for HCC with a histologically proven focal liver lesion on B-mode ultrasound were recruited prospectively in a multicenter approach. Clinical and imaging data were entered via online entry forms. The diagnostic accuracies for the noninvasive diagnosis of HCC were compared for the conventional interpretation of standardized CEUS at the time of the examination (= CEUS on-site) and the two CEUS algorithms ESCULAP (Erlanger Synopsis for Contrast-enhanced Ultrasound for Liver lesion Assessment in Patients at risk) and CEUS LI-RADS (Contrast-Enhanced UltraSound Liver Imaging Reporting and Data System). Results 321 patients were recruited in 43 centers; 299 (93.1 %) had liver cirrhosis. The diagnosis according to histology was HCC in 256 cases, and intrahepatic cholangiocarcinoma (iCCA) in 23 cases. In the subgroup of cirrhotic patients (n = 299), the highest sensitivity for the diagnosis of HCC was achieved with the CEUS algorithm ESCULAP (94.2 %) and CEUS on-site (90.9 %). The lowest sensitivity was reached with the CEUS LI-RADS algorithm (64 %; p < 0.001). However, the specificity of CEUS LI-RADS (78.9 %) was superior to that of ESCULAP (50.9 %) and CEUS on-site (64.9 %; p < 0.001). At the same time, the negative predictive value (NPV) of CEUS LI-RADS was significantly inferior to that of ESCULAP (34.1 % vs. 67.4 %; p < 0.001) and CEUS on-site (62.7 %; p < 0.001). The positive predictive values of all modalities were high (around 90 %), with the best results seen for CEUS LI-RADS and CEUS on-site. Conclusion This is the first multicenter, prospective comparison of standardized CEUS and the recently developed CEUS-based algorithms in histologically proven liver lesions in cirrhotic patients. Our results reaffirm the excellent diagnostic accuracy of CEUS for the noninvasive diagnosis of HCC in high-risk patients. However, on-site diagnosis by an experienced examiner achieves an almost equal diagnostic accuracy compared to CEUS-based diagnostic algorithms.


Author(s):  
D. Strobel ◽  
E.-M. Jung ◽  
M. Ziesch ◽  
M. Praktiknjo ◽  
A. Link ◽  
...  

Abstract Objectives Hepatocellular carcinoma (HCC) can be diagnosed non-invasively with contrast-enhanced ultrasound (CEUS) in cirrhosis if the characteristic pattern of arterial phase hyperenhancement followed by hypoenhancement is present. Recent studies suggest that diagnosis based on this “hyper-hypo” pattern needs further refinement. This study compares the diagnostic accuracies of standardized CEUS for HCC according to the current guideline definition and following the newly developed CEUS algorithms (CEUS LI-RADS®, ESCULAP) in a prospective multicenter real-life setting. Methods Cirrhotic patients with liver lesions on B-mode ultrasound were recruited prospectively from 04/2018 to 04/2019, and clinical and imaging data were collected. The CEUS standard included an additional examination point after 4–6 min in case of no washout after 3 min. The diagnostic accuracies of CEUS following the guidelines (“hyper-hypo” pattern), based on the examiner’s subjective interpretation (“CEUS subjective”), and based on the CEUS algorithms ESCULAP and CEUS LI-RADS® were compared. Results In total, 470 cirrhotic patients were recruited in 43 centers. The final diagnosis was HCC in 378 cases (80.4%) according to the reference standard (histology 77.4%, MRI 16.4%, CT 6.2%). The “hyper-hypo” pattern yielded 74.3% sensitivity and 63% specificity. “CEUS subjective” showed a higher diagnostic accuracy (sensitivity, 91.5%; specificity, 67.4%; positive predictive value, 92%; negative predictive value, 66%). Sensitivity was higher for ESCULAP (95%) and “CEUS subjective” (91.5%) versus CEUS LI-RADS® (65.2%; p < 0.001). Specificity was highest for CEUS LI-RADS® (78.6%; p < 0.001). Conclusions CEUS has an excellent diagnostic accuracy for the non-invasive diagnosis of HCC in cirrhosis. CEUS algorithms may be a helpful refinement of the “hyper-hypo” pattern defined by current HCC guidelines. Key Points • Contrast-enhanced ultrasound (CEUS) has a high diagnostic accuracy for the non-invasive diagnosis of hepatocellular carcinoma (HCC) in cirrhosis. • The CEUS algorithm ESCULAP (Erlanger Synopsis for Contrast-enhanced Ultrasound for Liver lesion Assessment in Patients at risk) showed the highest sensitivity, whereas the CEUS LI-RADS® (Contrast-Enhanced UltraSound Liver Imaging Reporting and Data System) algorithm yielded the highest specificity. • A standardized CEUS examination procedure with an additional examination point in the late phase, after 4–6 min in lesions with no washout after 3 min, is vital.


Sign in / Sign up

Export Citation Format

Share Document